Installation and commissioning of the JET-EP magnetic diagnostic system

Saved in:
Bibliographic Details
Title: Installation and commissioning of the JET-EP magnetic diagnostic system
Authors: Peruzzo, Simone1 simone.peruzzo@igi.cnr.it, Albanese, Raffaele2, Artaserse, Giovanni2, Coccorese, Vincenzo2, Gerasimov, Sergei3, Lam, Norman3, Maviglia, Francesco2, Pearson, Ian3, Prior, Phil3, Quercia, Antonio2, Zabeo, Luca3
Source: Fusion Engineering & Design. Jul2009, Vol. 84 Issue 7-11, p1495-1498. 4p.
Subjects: Plasma diagnostics, Feedback control systems, Remote handling (Radioactive substances), Physics experiments, Physics projects, Magnetic circuits, Real-time control
Abstract: Abstract: This paper describes the activities of installation and commissioning of the magnetic diagnostic enhancement for JET. The new system includes four sub-sets of probes located in the vessel in two opposite octants, for a total of 48 magnetic pick-up coils. The main goal of this enhancement is to improve the accuracy of the reconstruction of the plasma equilibrium and the performance of the real time feedback control of the plasma shape. After a brief description of the system, the paper focuses on the installation activities, accomplished during the 2007 shut-down using the JET remote handling system. The paper then concentrates on the analysis and interpretation of the data collected during the functional commissioning of the new system, carried out during the restart phase of the machine and the first part of the 2008 experimental campaigns, which proved the accuracy of the new signals and the achievement of the project goals. [Copyright &y& Elsevier]
Copyright of Fusion Engineering & Design is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Be the first to leave a comment!