Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometry.
Saved in:
| Title: | Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometry. |
|---|---|
| Authors: | Repetto, R.1, Siggers, J.2, Stocchino, A.3 |
| Source: | Biomechanics & Modeling in Mechanobiology. Feb2010, Vol. 9 Issue 1, p65-76. 12p. |
| Subjects: | Vitreous humor, Saccadic eye movements, Newtonian fluids, Vitreous body surgery, Torsional vibration, Mathematical models |
| Abstract: | Abstract  Saccadic eye rotations induce a flow in the vitreous humor of the eye. Any such flow is likely to have a significant influence on the dispersion of drugs injected into the vitreous chamber. The shape of this chamber deviates from a perfect sphere by up to 10â20% of the radius, which is predominantly due to an indentation caused by the lens. In this paper we investigate theoretically the effect of the domain shape upon the flow field generated by saccades by considering an idealized model. The posterior chamber geometry is assumed to be a sphere with a small indentation, undergoing prescribed small-amplitude sinusoidal torsional oscillations, and, as an initial step towards understanding the problem, we treat the vitreous humor as a Newtonian fluid filling the chamber. The latter assumption applies best in the case of a liquefied vitreous or a tamponade fluid introduced in the vitreous chamber after vitrectomy. We find the flow field in terms of vector spherical harmonics, focusing on the deviation from the flow that would be obtained in a perfect sphere. The flow induced by the departure of the domain geometry from the spherical shape has an oscillating component at leading order and a smaller-amplitude steady streaming flow. The oscillating component includes a circulation cell formed every half-period, which migrates from the indentation towards the center of the domain where it disappears. The steady component has two counter-rotating circulations in the anterior part of the domain. These findings are in good qualitative agreement with the experimental results of Stocchino et al. (Phys Med Biol 52:2021â2034, 2007). Our results predict a significant reduction in the expected time for drug dispersal across the eye compared with the situation in which there is no fluid flow present. [ABSTRACT FROM AUTHOR] |
| Copyright of Biomechanics & Modeling in Mechanobiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 47529073 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometry. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Repetto%2C+R%2E%22">Repetto, R.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Siggers%2C+J%2E%22">Siggers, J.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Stocchino%2C+A%2E%22">Stocchino, A.</searchLink><relatesTo>3</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Biomechanics+%26+Modeling+in+Mechanobiology%22">Biomechanics & Modeling in Mechanobiology</searchLink>. Feb2010, Vol. 9 Issue 1, p65-76. 12p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Vitreous+humor%22">Vitreous humor</searchLink><br /><searchLink fieldCode="DE" term="%22Saccadic+eye+movements%22">Saccadic eye movements</searchLink><br /><searchLink fieldCode="DE" term="%22Newtonian+fluids%22">Newtonian fluids</searchLink><br /><searchLink fieldCode="DE" term="%22Vitreous+body+surgery%22">Vitreous body surgery</searchLink><br /><searchLink fieldCode="DE" term="%22Torsional+vibration%22">Torsional vibration</searchLink><br /><searchLink fieldCode="DE" term="%22Mathematical+models%22">Mathematical models</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Abstract  Saccadic eye rotations induce a flow in the vitreous humor of the eye. Any such flow is likely to have a significant influence on the dispersion of drugs injected into the vitreous chamber. The shape of this chamber deviates from a perfect sphere by up to 10â20% of the radius, which is predominantly due to an indentation caused by the lens. In this paper we investigate theoretically the effect of the domain shape upon the flow field generated by saccades by considering an idealized model. The posterior chamber geometry is assumed to be a sphere with a small indentation, undergoing prescribed small-amplitude sinusoidal torsional oscillations, and, as an initial step towards understanding the problem, we treat the vitreous humor as a Newtonian fluid filling the chamber. The latter assumption applies best in the case of a liquefied vitreous or a tamponade fluid introduced in the vitreous chamber after vitrectomy. We find the flow field in terms of vector spherical harmonics, focusing on the deviation from the flow that would be obtained in a perfect sphere. The flow induced by the departure of the domain geometry from the spherical shape has an oscillating component at leading order and a smaller-amplitude steady streaming flow. The oscillating component includes a circulation cell formed every half-period, which migrates from the indentation towards the center of the domain where it disappears. The steady component has two counter-rotating circulations in the anterior part of the domain. These findings are in good qualitative agreement with the experimental results of Stocchino et al. (Phys Med Biol 52:2021â2034, 2007). Our results predict a significant reduction in the expected time for drug dispersal across the eye compared with the situation in which there is no fluid flow present. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Biomechanics & Modeling in Mechanobiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=47529073 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s10237-009-0159-0 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 12 StartPage: 65 Subjects: – SubjectFull: Vitreous humor Type: general – SubjectFull: Saccadic eye movements Type: general – SubjectFull: Newtonian fluids Type: general – SubjectFull: Vitreous body surgery Type: general – SubjectFull: Torsional vibration Type: general – SubjectFull: Mathematical models Type: general Titles: – TitleFull: Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometry. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Repetto, R. – PersonEntity: Name: NameFull: Siggers, J. – PersonEntity: Name: NameFull: Stocchino, A. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 02 Text: Feb2010 Type: published Y: 2010 Identifiers: – Type: issn-print Value: 16177959 Numbering: – Type: volume Value: 9 – Type: issue Value: 1 Titles: – TitleFull: Biomechanics & Modeling in Mechanobiology Type: main |
| ResultId | 1 |