Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometry.

Saved in:
Bibliographic Details
Title: Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometry.
Authors: Repetto, R.1, Siggers, J.2, Stocchino, A.3
Source: Biomechanics & Modeling in Mechanobiology. Feb2010, Vol. 9 Issue 1, p65-76. 12p.
Subjects: Vitreous humor, Saccadic eye movements, Newtonian fluids, Vitreous body surgery, Torsional vibration, Mathematical models
Abstract: Abstract  Saccadic eye rotations induce a flow in the vitreous humor of the eye. Any such flow is likely to have a significant influence on the dispersion of drugs injected into the vitreous chamber. The shape of this chamber deviates from a perfect sphere by up to 10–20% of the radius, which is predominantly due to an indentation caused by the lens. In this paper we investigate theoretically the effect of the domain shape upon the flow field generated by saccades by considering an idealized model. The posterior chamber geometry is assumed to be a sphere with a small indentation, undergoing prescribed small-amplitude sinusoidal torsional oscillations, and, as an initial step towards understanding the problem, we treat the vitreous humor as a Newtonian fluid filling the chamber. The latter assumption applies best in the case of a liquefied vitreous or a tamponade fluid introduced in the vitreous chamber after vitrectomy. We find the flow field in terms of vector spherical harmonics, focusing on the deviation from the flow that would be obtained in a perfect sphere. The flow induced by the departure of the domain geometry from the spherical shape has an oscillating component at leading order and a smaller-amplitude steady streaming flow. The oscillating component includes a circulation cell formed every half-period, which migrates from the indentation towards the center of the domain where it disappears. The steady component has two counter-rotating circulations in the anterior part of the domain. These findings are in good qualitative agreement with the experimental results of Stocchino et al. (Phys Med Biol 52:2021–2034, 2007). Our results predict a significant reduction in the expected time for drug dispersal across the eye compared with the situation in which there is no fluid flow present. [ABSTRACT FROM AUTHOR]
Copyright of Biomechanics & Modeling in Mechanobiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 47529073
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometry.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Repetto%2C+R%2E%22">Repetto, R.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Siggers%2C+J%2E%22">Siggers, J.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Stocchino%2C+A%2E%22">Stocchino, A.</searchLink><relatesTo>3</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Biomechanics+%26+Modeling+in+Mechanobiology%22">Biomechanics & Modeling in Mechanobiology</searchLink>. Feb2010, Vol. 9 Issue 1, p65-76. 12p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Vitreous+humor%22">Vitreous humor</searchLink><br /><searchLink fieldCode="DE" term="%22Saccadic+eye+movements%22">Saccadic eye movements</searchLink><br /><searchLink fieldCode="DE" term="%22Newtonian+fluids%22">Newtonian fluids</searchLink><br /><searchLink fieldCode="DE" term="%22Vitreous+body+surgery%22">Vitreous body surgery</searchLink><br /><searchLink fieldCode="DE" term="%22Torsional+vibration%22">Torsional vibration</searchLink><br /><searchLink fieldCode="DE" term="%22Mathematical+models%22">Mathematical models</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Abstract  Saccadic eye rotations induce a flow in the vitreous humor of the eye. Any such flow is likely to have a significant influence on the dispersion of drugs injected into the vitreous chamber. The shape of this chamber deviates from a perfect sphere by up to 10–20% of the radius, which is predominantly due to an indentation caused by the lens. In this paper we investigate theoretically the effect of the domain shape upon the flow field generated by saccades by considering an idealized model. The posterior chamber geometry is assumed to be a sphere with a small indentation, undergoing prescribed small-amplitude sinusoidal torsional oscillations, and, as an initial step towards understanding the problem, we treat the vitreous humor as a Newtonian fluid filling the chamber. The latter assumption applies best in the case of a liquefied vitreous or a tamponade fluid introduced in the vitreous chamber after vitrectomy. We find the flow field in terms of vector spherical harmonics, focusing on the deviation from the flow that would be obtained in a perfect sphere. The flow induced by the departure of the domain geometry from the spherical shape has an oscillating component at leading order and a smaller-amplitude steady streaming flow. The oscillating component includes a circulation cell formed every half-period, which migrates from the indentation towards the center of the domain where it disappears. The steady component has two counter-rotating circulations in the anterior part of the domain. These findings are in good qualitative agreement with the experimental results of Stocchino et al. (Phys Med Biol 52:2021–2034, 2007). Our results predict a significant reduction in the expected time for drug dispersal across the eye compared with the situation in which there is no fluid flow present. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Biomechanics & Modeling in Mechanobiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=47529073
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10237-009-0159-0
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 12
        StartPage: 65
    Subjects:
      – SubjectFull: Vitreous humor
        Type: general
      – SubjectFull: Saccadic eye movements
        Type: general
      – SubjectFull: Newtonian fluids
        Type: general
      – SubjectFull: Vitreous body surgery
        Type: general
      – SubjectFull: Torsional vibration
        Type: general
      – SubjectFull: Mathematical models
        Type: general
    Titles:
      – TitleFull: Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometry.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Repetto, R.
      – PersonEntity:
          Name:
            NameFull: Siggers, J.
      – PersonEntity:
          Name:
            NameFull: Stocchino, A.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 02
              Text: Feb2010
              Type: published
              Y: 2010
          Identifiers:
            – Type: issn-print
              Value: 16177959
          Numbering:
            – Type: volume
              Value: 9
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Biomechanics & Modeling in Mechanobiology
              Type: main
ResultId 1