Compact Model of a Slotless Tubular Linear Generator for Renewable Energy Performance Assessments.

Saved in:
Bibliographic Details
Title: Compact Model of a Slotless Tubular Linear Generator for Renewable Energy Performance Assessments.
Authors: Cheng-Tsung Liu1 ctliu@ieee.org, Chien-Lin Lin1, Chang-Chou Hwang2, Chun-Hung Tu1
Source: IEEE Transactions on Magnetics. Jun2010, Vol. 46 Issue 6, p1467-1470. 4p.
Subjects: Permanent magnets, Electricity, Electromagnetism, Bessel functions, Magnets
Abstract: A slotless tubular linear generator (STLG) can be connected directly to renewable energy sources for generating electricity in a reciprocating force pattern with no extra mechanical cogging losses. This paper presents an analytical model for predicting the electromagnetic and electromechanical characteristics of a STLG, such that the preliminary operational performance of the STLG in potential applications can be conveniently evaluated. From the devised Bessel-based system model, both the unregulated and regulated generator outputs with and without power converter circuits included can then be thoroughly investigated. Experimental measurements obtained from a laboratory test-bed have also been provided to confirm the validity and adequacy of the proposed model for related performance assessments. [ABSTRACT FROM AUTHOR]
Copyright of IEEE Transactions on Magnetics is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 51117621
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Compact Model of a Slotless Tubular Linear Generator for Renewable Energy Performance Assessments.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Cheng-Tsung+Liu%22">Cheng-Tsung Liu</searchLink><relatesTo>1</relatesTo><i> ctliu@ieee.org</i><br /><searchLink fieldCode="AR" term="%22Chien-Lin+Lin%22">Chien-Lin Lin</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Chang-Chou+Hwang%22">Chang-Chou Hwang</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Chun-Hung+Tu%22">Chun-Hung Tu</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22IEEE+Transactions+on+Magnetics%22">IEEE Transactions on Magnetics</searchLink>. Jun2010, Vol. 46 Issue 6, p1467-1470. 4p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Permanent+magnets%22">Permanent magnets</searchLink><br /><searchLink fieldCode="DE" term="%22Electricity%22">Electricity</searchLink><br /><searchLink fieldCode="DE" term="%22Electromagnetism%22">Electromagnetism</searchLink><br /><searchLink fieldCode="DE" term="%22Bessel+functions%22">Bessel functions</searchLink><br /><searchLink fieldCode="DE" term="%22Magnets%22">Magnets</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: A slotless tubular linear generator (STLG) can be connected directly to renewable energy sources for generating electricity in a reciprocating force pattern with no extra mechanical cogging losses. This paper presents an analytical model for predicting the electromagnetic and electromechanical characteristics of a STLG, such that the preliminary operational performance of the STLG in potential applications can be conveniently evaluated. From the devised Bessel-based system model, both the unregulated and regulated generator outputs with and without power converter circuits included can then be thoroughly investigated. Experimental measurements obtained from a laboratory test-bed have also been provided to confirm the validity and adequacy of the proposed model for related performance assessments. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of IEEE Transactions on Magnetics is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=51117621
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1109/TMAG.2010.2042037
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 4
        StartPage: 1467
    Subjects:
      – SubjectFull: Permanent magnets
        Type: general
      – SubjectFull: Electricity
        Type: general
      – SubjectFull: Electromagnetism
        Type: general
      – SubjectFull: Bessel functions
        Type: general
      – SubjectFull: Magnets
        Type: general
    Titles:
      – TitleFull: Compact Model of a Slotless Tubular Linear Generator for Renewable Energy Performance Assessments.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Cheng-Tsung Liu
      – PersonEntity:
          Name:
            NameFull: Chien-Lin Lin
      – PersonEntity:
          Name:
            NameFull: Chang-Chou Hwang
      – PersonEntity:
          Name:
            NameFull: Chun-Hung Tu
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2010
              Type: published
              Y: 2010
          Identifiers:
            – Type: issn-print
              Value: 00189464
          Numbering:
            – Type: volume
              Value: 46
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: IEEE Transactions on Magnetics
              Type: main
ResultId 1