Numerical simulations of gas flows through an open, non-contact cell for LA-ICP-MS.

Saved in:
Bibliographic Details
Title: Numerical simulations of gas flows through an open, non-contact cell for LA-ICP-MS.
Authors: Dhinesh Asogan1,2, Barry L. Sharp1, Ciaran J. P. O'Connor3, Damon A. Green3, Jay Wilkins4
Source: JAAS (Journal of Analytical Atomic Spectrometry). Mar2011, Vol. 26 Issue 3, p631-634. 4p.
Subjects: Gas flow, Laser ablation, Simulation methods & models, Atmosphere, Particles, Gas dynamics, Inductively coupled plasma mass spectrometry
Abstract: Numerical simulations of gas flows through an open, non-contact cell for laser ablation are presented. The cell consists of dual, annular, concentric micro-jet gas arrays to entrain ablated material (the carrier flow) and exclude atmosphere (the curtain flow). This study shows that the design of the cell affords a very high degree of exclusion of atmospheric gases, using a relatively low curtain flow of 2.5 l min−1(with a carrier flow of 1.2 l min−1He), and demonstrates the efficacy of the micro-jet arrays in providing an axially symmetric exclusion zone. Minimum particle transit times through the cell were calculated to be of the order of 50–100 ms. [ABSTRACT FROM AUTHOR]
Copyright of JAAS (Journal of Analytical Atomic Spectrometry) is the property of Royal Society of Chemistry and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Numerical simulations of gas flows through an open, non-contact cell for laser ablation are presented. The cell consists of dual, annular, concentric micro-jet gas arrays to entrain ablated material (the carrier flow) and exclude atmosphere (the curtain flow). This study shows that the design of the cell affords a very high degree of exclusion of atmospheric gases, using a relatively low curtain flow of 2.5 l min−1(with a carrier flow of 1.2 l min−1He), and demonstrates the efficacy of the micro-jet arrays in providing an axially symmetric exclusion zone. Minimum particle transit times through the cell were calculated to be of the order of 50–100 ms. [ABSTRACT FROM AUTHOR]
ISSN:02679477
DOI:10.1039/C0JA00166J