Evaluation of the quantitative accuracy of a commercially available positron emission mammography scanner.

Saved in:
Bibliographic Details
Title: Evaluation of the quantitative accuracy of a commercially available positron emission mammography scanner.
Authors: Springer, Adam1, Mawlawi, Osama R.1
Source: Medical Physics. Apr2011, Vol. 38 Issue 4, p2132-2139. 8p.
Subjects: Positron emission, Mammograms, Scanning systems, Image reconstruction, Attenuation of light, Simulation methods & models, Scattering (Physics)
Abstract: Purpose: The PEM Flex Solo II (Naviscan, Inc., San Diego, CA) is currently the only commercially available positron emission mammography (PEM) scanner. This scanner does not apply corrections for count rate effects, attenuation, or scatter during image reconstruction, potentially affecting the quantitative accuracy of images. The aim of this work is to measure the overall quantitative accuracy of the PEM Flex system and to determine the individual contributions of error from count rate effects, attenuation, and scatter. Methods: Gelatin phantoms were designed to simulate breasts of different thicknesses (4-12 cm) with varying uniform background activity concentration (AC) (0.007-0.5 μCi/cc), cysts, and lesions (2:1, 5:1, and 10:1 lesion-to-background ratios). The overall error was calculated from ROI measurements in the phantoms with a clinically relevant background AC (0.065 μCi/cc). The error due to count rate effects was determined by comparing the overall error at multiple background AC to the error at a very low background AC (0.007 μCi/cc) where count rate effects are considered negligible. A point source and cold gelatin phantoms of different thicknesses were used to assess the errors due to attenuation and scatter. The maximum pixel values of the point source in gelatin and in air were compared to determine the effect of attenuation, while scatter was evaluated by comparing the sum of all pixel values in gelatin and in air. Results: The AC in the uniform background was underestimated in phantoms of all thicknesses, with the exception of the 4-cm-thick phantoms in which the measured AC was within ±7% of the true value (0.065 μCi/cc). The degree of underestimation in the uniform background increased with the phantom thickness, up to 34%±6% in the 12 cm phantoms. The AC in all lesions was underestimated by more than that measured in the background (22% for the 2:1 lesions in the 4 cm phantom) and this underestimation increased with increasing thickness and lesion-to-background ratio (85% for the 10:1 lesions in the 12 cm phantoms). The error due to count rate effects reduced the measured AC with respect to its true value. This error increased with increasing background AC (23%±6% at 0.065 μCi/cc to 85%±1% at 0.5 μCi/cc for the 4 cm phantoms) and decreased with increasing phantom thickness (23%±6% for the 4-cm-thick phantoms to 7%±7% for the 12-cm-thick phantoms at 0.065 μCi/cc). Attenuation was a substantial source of error and reduced the measured AC by 51%±10%-77%±4% in the 4-12 cm phantoms, respectively. Scatter increased the total signal measured in images by a relatively constant amount (23%±9%) for all thicknesses. Conclusions: Applying corrections for count rate effects, attenuation, and scatter will be essential for the PEM Flex Solo II to be able to produce quantitatively accurate images. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 59744737
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Evaluation of the quantitative accuracy of a commercially available positron emission mammography scanner.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Springer%2C+Adam%22">Springer, Adam</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Mawlawi%2C+Osama+R%2E%22">Mawlawi, Osama R.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Apr2011, Vol. 38 Issue 4, p2132-2139. 8p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Positron+emission%22">Positron emission</searchLink><br /><searchLink fieldCode="DE" term="%22Mammograms%22">Mammograms</searchLink><br /><searchLink fieldCode="DE" term="%22Scanning+systems%22">Scanning systems</searchLink><br /><searchLink fieldCode="DE" term="%22Image+reconstruction%22">Image reconstruction</searchLink><br /><searchLink fieldCode="DE" term="%22Attenuation+of+light%22">Attenuation of light</searchLink><br /><searchLink fieldCode="DE" term="%22Simulation+methods+%26+models%22">Simulation methods & models</searchLink><br /><searchLink fieldCode="DE" term="%22Scattering+%28Physics%29%22">Scattering (Physics)</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: The PEM Flex Solo II (Naviscan, Inc., San Diego, CA) is currently the only commercially available positron emission mammography (PEM) scanner. This scanner does not apply corrections for count rate effects, attenuation, or scatter during image reconstruction, potentially affecting the quantitative accuracy of images. The aim of this work is to measure the overall quantitative accuracy of the PEM Flex system and to determine the individual contributions of error from count rate effects, attenuation, and scatter. Methods: Gelatin phantoms were designed to simulate breasts of different thicknesses (4-12 cm) with varying uniform background activity concentration (AC) (0.007-0.5 μCi/cc), cysts, and lesions (2:1, 5:1, and 10:1 lesion-to-background ratios). The overall error was calculated from ROI measurements in the phantoms with a clinically relevant background AC (0.065 μCi/cc). The error due to count rate effects was determined by comparing the overall error at multiple background AC to the error at a very low background AC (0.007 μCi/cc) where count rate effects are considered negligible. A point source and cold gelatin phantoms of different thicknesses were used to assess the errors due to attenuation and scatter. The maximum pixel values of the point source in gelatin and in air were compared to determine the effect of attenuation, while scatter was evaluated by comparing the sum of all pixel values in gelatin and in air. Results: The AC in the uniform background was underestimated in phantoms of all thicknesses, with the exception of the 4-cm-thick phantoms in which the measured AC was within ±7% of the true value (0.065 μCi/cc). The degree of underestimation in the uniform background increased with the phantom thickness, up to 34%±6% in the 12 cm phantoms. The AC in all lesions was underestimated by more than that measured in the background (22% for the 2:1 lesions in the 4 cm phantom) and this underestimation increased with increasing thickness and lesion-to-background ratio (85% for the 10:1 lesions in the 12 cm phantoms). The error due to count rate effects reduced the measured AC with respect to its true value. This error increased with increasing background AC (23%±6% at 0.065 μCi/cc to 85%±1% at 0.5 μCi/cc for the 4 cm phantoms) and decreased with increasing phantom thickness (23%±6% for the 4-cm-thick phantoms to 7%±7% for the 12-cm-thick phantoms at 0.065 μCi/cc). Attenuation was a substantial source of error and reduced the measured AC by 51%±10%-77%±4% in the 4-12 cm phantoms, respectively. Scatter increased the total signal measured in images by a relatively constant amount (23%±9%) for all thicknesses. Conclusions: Applying corrections for count rate effects, attenuation, and scatter will be essential for the PEM Flex Solo II to be able to produce quantitatively accurate images. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=59744737
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1118/1.3560881
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 2132
    Subjects:
      – SubjectFull: Positron emission
        Type: general
      – SubjectFull: Mammograms
        Type: general
      – SubjectFull: Scanning systems
        Type: general
      – SubjectFull: Image reconstruction
        Type: general
      – SubjectFull: Attenuation of light
        Type: general
      – SubjectFull: Simulation methods & models
        Type: general
      – SubjectFull: Scattering (Physics)
        Type: general
    Titles:
      – TitleFull: Evaluation of the quantitative accuracy of a commercially available positron emission mammography scanner.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Springer, Adam
      – PersonEntity:
          Name:
            NameFull: Mawlawi, Osama R.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2011
              Type: published
              Y: 2011
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 38
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1