Study of the size-based environmental availability of metals associated to natural organic matter by stable isotope exchange and quadrupole inductively coupled plasma mass spectrometry coupled to asymmetrical flow field flow fractionation

Saved in:
Bibliographic Details
Title: Study of the size-based environmental availability of metals associated to natural organic matter by stable isotope exchange and quadrupole inductively coupled plasma mass spectrometry coupled to asymmetrical flow field flow fractionation
Authors: Laborda, F. flaborda@unizar.es, Ruiz-Beguería, S.1, Bolea, E.1, Castillo, J.R.1
Source: Journal of Chromatography A. Jul2011, Vol. 1218 Issue 27, p4199-4205. 7p.
Subjects: Organic compounds, Stable isotopes, Quadrupoles, Inductively coupled plasma mass spectrometry, Field-flow fractionation, Asymmetry (Chemistry), Metals, Suspensions (Chemistry), Colloids, Separation (Technology)
Abstract: Abstract: The determination of the isotopically exchangeable fraction of metals in environmental solid samples (soils, composts, sediments, sludges, etc.) is used to know the amount of metal potentially available (E-value). Stable isotopes can be used for determination of E-values through the analysis of the aqueous phases from spiked suspensions. However, the presence of isotopically non-exchangeable metal forms in the aqueous phase led to overestimation of the E-values. In this paper, a method for monitoring the degree of isotopic exchange in function of the molecular mass and/or size of the metal form has been developed based on the direct coupling of asymmetrical flow field flow fractionation (AsFlFFF) with inductively coupled plasma mass spectrometry (ICP-MS) for on-line isotope ratio measurements. ICP-MS data acquisition parameters were stressed to avoid degradation of isotope ratio precision. Two sets of fractionation conditions were selected: a colloids separation, which allowed the separation of substances up to 1μm, and a macromolecules separation, designed to resolve small size substances up to 50kDa. The methodology was applied to study the environmental availability of copper and lead in compost samples, where metals are mainly associated to different forms of organic matter. No significant differences on isotopic exchange were observed over the size range studied, validating the E-values determined by direct analysis of the aqueous phases. [Copyright &y& Elsevier]
Copyright of Journal of Chromatography A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 61488516
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Study of the size-based environmental availability of metals associated to natural organic matter by stable isotope exchange and quadrupole inductively coupled plasma mass spectrometry coupled to asymmetrical flow field flow fractionation
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Laborda%2C+F%2E%22">Laborda, F.</searchLink><i> flaborda@unizar.es</i><br /><searchLink fieldCode="AR" term="%22Ruiz-Beguería%2C+S%2E%22">Ruiz-Beguería, S.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Bolea%2C+E%2E%22">Bolea, E.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Castillo%2C+J%2ER%2E%22">Castillo, J.R.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Journal+of+Chromatography+A%22">Journal of Chromatography A</searchLink>. Jul2011, Vol. 1218 Issue 27, p4199-4205. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Organic+compounds%22">Organic compounds</searchLink><br /><searchLink fieldCode="DE" term="%22Stable+isotopes%22">Stable isotopes</searchLink><br /><searchLink fieldCode="DE" term="%22Quadrupoles%22">Quadrupoles</searchLink><br /><searchLink fieldCode="DE" term="%22Inductively+coupled+plasma+mass+spectrometry%22">Inductively coupled plasma mass spectrometry</searchLink><br /><searchLink fieldCode="DE" term="%22Field-flow+fractionation%22">Field-flow fractionation</searchLink><br /><searchLink fieldCode="DE" term="%22Asymmetry+%28Chemistry%29%22">Asymmetry (Chemistry)</searchLink><br /><searchLink fieldCode="DE" term="%22Metals%22">Metals</searchLink><br /><searchLink fieldCode="DE" term="%22Suspensions+%28Chemistry%29%22">Suspensions (Chemistry)</searchLink><br /><searchLink fieldCode="DE" term="%22Colloids%22">Colloids</searchLink><br /><searchLink fieldCode="DE" term="%22Separation+%28Technology%29%22">Separation (Technology)</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Abstract: The determination of the isotopically exchangeable fraction of metals in environmental solid samples (soils, composts, sediments, sludges, etc.) is used to know the amount of metal potentially available (E-value). Stable isotopes can be used for determination of E-values through the analysis of the aqueous phases from spiked suspensions. However, the presence of isotopically non-exchangeable metal forms in the aqueous phase led to overestimation of the E-values. In this paper, a method for monitoring the degree of isotopic exchange in function of the molecular mass and/or size of the metal form has been developed based on the direct coupling of asymmetrical flow field flow fractionation (AsFlFFF) with inductively coupled plasma mass spectrometry (ICP-MS) for on-line isotope ratio measurements. ICP-MS data acquisition parameters were stressed to avoid degradation of isotope ratio precision. Two sets of fractionation conditions were selected: a colloids separation, which allowed the separation of substances up to 1μm, and a macromolecules separation, designed to resolve small size substances up to 50kDa. The methodology was applied to study the environmental availability of copper and lead in compost samples, where metals are mainly associated to different forms of organic matter. No significant differences on isotopic exchange were observed over the size range studied, validating the E-values determined by direct analysis of the aqueous phases. [Copyright &y& Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Journal of Chromatography A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=61488516
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.chroma.2011.01.076
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 4199
    Subjects:
      – SubjectFull: Organic compounds
        Type: general
      – SubjectFull: Stable isotopes
        Type: general
      – SubjectFull: Quadrupoles
        Type: general
      – SubjectFull: Inductively coupled plasma mass spectrometry
        Type: general
      – SubjectFull: Field-flow fractionation
        Type: general
      – SubjectFull: Asymmetry (Chemistry)
        Type: general
      – SubjectFull: Metals
        Type: general
      – SubjectFull: Suspensions (Chemistry)
        Type: general
      – SubjectFull: Colloids
        Type: general
      – SubjectFull: Separation (Technology)
        Type: general
    Titles:
      – TitleFull: Study of the size-based environmental availability of metals associated to natural organic matter by stable isotope exchange and quadrupole inductively coupled plasma mass spectrometry coupled to asymmetrical flow field flow fractionation
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Laborda, F.
      – PersonEntity:
          Name:
            NameFull: Ruiz-Beguería, S.
      – PersonEntity:
          Name:
            NameFull: Bolea, E.
      – PersonEntity:
          Name:
            NameFull: Castillo, J.R.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 08
              M: 07
              Text: Jul2011
              Type: published
              Y: 2011
          Identifiers:
            – Type: issn-print
              Value: 00219673
          Numbering:
            – Type: volume
              Value: 1218
            – Type: issue
              Value: 27
          Titles:
            – TitleFull: Journal of Chromatography A
              Type: main
ResultId 1