Pulse pileup statistics for energy discriminating photon counting x-ray detectors.
Saved in:
| Title: | Pulse pileup statistics for energy discriminating photon counting x-ray detectors. |
|---|---|
| Authors: | Wang, Adam S.1, Harrison, Daniel2, Lobastov, Vladimir2, Tkaczyk, J. Eric2 |
| Source: | Medical Physics. Jul2011, Vol. 38 Issue 7, p4265-4275. 11p. |
| Subjects: | Optical detectors, X-ray equipment, Photons, Performance evaluation, Electronic noise, Imaging systems, Monte Carlo method |
| Abstract: | Purpose: Energy discriminating photon counting x-ray detectors can be subject to a wide range of flux rates if applied in clinical settings. Even when the incident rate is a small fraction of the detector's maximum periodic rate N0, pulse pileup leads to count rate losses and spectral distortion. Although the deterministic effects can be corrected, the detrimental effect of pileup on image noise is not well understood and may limit the performance of photon counting systems. Therefore, the authors devise a method to determine the detector count statistics and imaging performance. Methods: The detector count statistics are derived analytically for an idealized pileup model with delta pulses of a nonparalyzable detector. These statistics are then used to compute the performance (e.g., contrast-to-noise ratio) for both single material and material decomposition contrast detection tasks via the Cramér-Rao lower bound (CRLB) as a function of the detector input count rate. With more realistic unipolar and bipolar pulse pileup models of a nonparalyzable detector, the imaging task performance is determined by Monte Carlo simulations and also approximated by a multinomial method based solely on the mean detected output spectrum. Photon counting performance at different count rates is compared with ideal energy integration, which is unaffected by count rate. Results: The authors found that an ideal photon counting detector with perfect energy resolution outperforms energy integration for our contrast detection tasks, but when the input count rate exceeds 20% N0, many of these benefits disappear. The benefit with iodine contrast falls rapidly with increased count rate while water contrast is not as sensitive to count rates. The performance with a delta pulse model is overoptimistic when compared to the more realistic bipolar pulse model. The multinomial approximation predicts imaging performance very close to the prediction from Monte Carlo simulations. The monoenergetic image with maximum contrast-to-noise ratio from dual energy imaging with ideal photon counting is only slightly better than with dual kVp energy integration, and with a bipolar pulse model, energy integration outperforms photon counting for this particular metric because of the count rate losses. However, the material resolving capability of photon counting can be superior to energy integration with dual kVp even in the presence of pileup because of the energy information available to photon counting. Conclusions: A computationally efficient multinomial approximation of the count statistics that is based on the mean output spectrum can accurately predict imaging performance. This enables photon counting system designers to directly relate the effect of pileup to its impact on imaging statistics and how to best take advantage of the benefits of energy discriminating photon counting detectors, such as material separation with spectral imaging. [ABSTRACT FROM AUTHOR] |
| Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 62271504 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Pulse pileup statistics for energy discriminating photon counting x-ray detectors. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Wang%2C+Adam+S%2E%22">Wang, Adam S.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Harrison%2C+Daniel%22">Harrison, Daniel</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Lobastov%2C+Vladimir%22">Lobastov, Vladimir</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Tkaczyk%2C+J%2E+Eric%22">Tkaczyk, J. Eric</searchLink><relatesTo>2</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Jul2011, Vol. 38 Issue 7, p4265-4275. 11p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Optical+detectors%22">Optical detectors</searchLink><br /><searchLink fieldCode="DE" term="%22X-ray+equipment%22">X-ray equipment</searchLink><br /><searchLink fieldCode="DE" term="%22Photons%22">Photons</searchLink><br /><searchLink fieldCode="DE" term="%22Performance+evaluation%22">Performance evaluation</searchLink><br /><searchLink fieldCode="DE" term="%22Electronic+noise%22">Electronic noise</searchLink><br /><searchLink fieldCode="DE" term="%22Imaging+systems%22">Imaging systems</searchLink><br /><searchLink fieldCode="DE" term="%22Monte+Carlo+method%22">Monte Carlo method</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: Energy discriminating photon counting x-ray detectors can be subject to a wide range of flux rates if applied in clinical settings. Even when the incident rate is a small fraction of the detector's maximum periodic rate N0, pulse pileup leads to count rate losses and spectral distortion. Although the deterministic effects can be corrected, the detrimental effect of pileup on image noise is not well understood and may limit the performance of photon counting systems. Therefore, the authors devise a method to determine the detector count statistics and imaging performance. Methods: The detector count statistics are derived analytically for an idealized pileup model with delta pulses of a nonparalyzable detector. These statistics are then used to compute the performance (e.g., contrast-to-noise ratio) for both single material and material decomposition contrast detection tasks via the Cramér-Rao lower bound (CRLB) as a function of the detector input count rate. With more realistic unipolar and bipolar pulse pileup models of a nonparalyzable detector, the imaging task performance is determined by Monte Carlo simulations and also approximated by a multinomial method based solely on the mean detected output spectrum. Photon counting performance at different count rates is compared with ideal energy integration, which is unaffected by count rate. Results: The authors found that an ideal photon counting detector with perfect energy resolution outperforms energy integration for our contrast detection tasks, but when the input count rate exceeds 20% N0, many of these benefits disappear. The benefit with iodine contrast falls rapidly with increased count rate while water contrast is not as sensitive to count rates. The performance with a delta pulse model is overoptimistic when compared to the more realistic bipolar pulse model. The multinomial approximation predicts imaging performance very close to the prediction from Monte Carlo simulations. The monoenergetic image with maximum contrast-to-noise ratio from dual energy imaging with ideal photon counting is only slightly better than with dual kVp energy integration, and with a bipolar pulse model, energy integration outperforms photon counting for this particular metric because of the count rate losses. However, the material resolving capability of photon counting can be superior to energy integration with dual kVp even in the presence of pileup because of the energy information available to photon counting. Conclusions: A computationally efficient multinomial approximation of the count statistics that is based on the mean output spectrum can accurately predict imaging performance. This enables photon counting system designers to directly relate the effect of pileup to its impact on imaging statistics and how to best take advantage of the benefits of energy discriminating photon counting detectors, such as material separation with spectral imaging. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=62271504 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1118/1.3592932 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 11 StartPage: 4265 Subjects: – SubjectFull: Optical detectors Type: general – SubjectFull: X-ray equipment Type: general – SubjectFull: Photons Type: general – SubjectFull: Performance evaluation Type: general – SubjectFull: Electronic noise Type: general – SubjectFull: Imaging systems Type: general – SubjectFull: Monte Carlo method Type: general Titles: – TitleFull: Pulse pileup statistics for energy discriminating photon counting x-ray detectors. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Wang, Adam S. – PersonEntity: Name: NameFull: Harrison, Daniel – PersonEntity: Name: NameFull: Lobastov, Vladimir – PersonEntity: Name: NameFull: Tkaczyk, J. Eric IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 07 Text: Jul2011 Type: published Y: 2011 Identifiers: – Type: issn-print Value: 00942405 Numbering: – Type: volume Value: 38 – Type: issue Value: 7 Titles: – TitleFull: Medical Physics Type: main |
| ResultId | 1 |