Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.

Saved in:
Bibliographic Details
Title: Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.
Authors: Saekho, Suwit1, Boada, Fernando E.1,2, Noll, Douglas C.3, Stenger, V. Andrew1,2
Source: Magnetic Resonance in Medicine. Feb2005, Vol. 53 Issue 2, p479-484. 6p.
Abstract: This work presents a small tip-angle 3D tailored RF slab-select pulse for reducing the B1 field inhomogeneity at 3T. The compensated slice profile was determined from a B1 inhomogeneity map. SNR improvement and degree of artifact reduction were evaluated in a NiCl2 doped phantom and human brains. The technique was found to reduce inhomogeneities as large as 30% of the peak image magnitude in all three spatial directions in the brain using a standard head coil. Magn Reson Med 53:479-484, 2005. © 2005 Wiley-Liss, Inc. [ABSTRACT FROM AUTHOR]
Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 63346162
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B<subscript>1</subscript> inhomogeneity at 3 T.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Saekho%2C+Suwit%22">Saekho, Suwit</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Boada%2C+Fernando+E%2E%22">Boada, Fernando E.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Noll%2C+Douglas+C%2E%22">Noll, Douglas C.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Stenger%2C+V%2E+Andrew%22">Stenger, V. Andrew</searchLink><relatesTo>1,2</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Magnetic+Resonance+in+Medicine%22">Magnetic Resonance in Medicine</searchLink>. Feb2005, Vol. 53 Issue 2, p479-484. 6p.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: This work presents a small tip-angle 3D tailored RF slab-select pulse for reducing the B1 field inhomogeneity at 3T. The compensated slice profile was determined from a B1 inhomogeneity map. SNR improvement and degree of artifact reduction were evaluated in a NiCl2 doped phantom and human brains. The technique was found to reduce inhomogeneities as large as 30% of the peak image magnitude in all three spatial directions in the brain using a standard head coil. Magn Reson Med 53:479-484, 2005. © 2005 Wiley-Liss, Inc. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=63346162
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mrm.20358
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 479
    Titles:
      – TitleFull: Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Saekho, Suwit
      – PersonEntity:
          Name:
            NameFull: Boada, Fernando E.
      – PersonEntity:
          Name:
            NameFull: Noll, Douglas C.
      – PersonEntity:
          Name:
            NameFull: Stenger, V. Andrew
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 02
              Text: Feb2005
              Type: published
              Y: 2005
          Identifiers:
            – Type: issn-print
              Value: 07403194
          Numbering:
            – Type: volume
              Value: 53
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Magnetic Resonance in Medicine
              Type: main
ResultId 1