Oxygen-sensitive contrast in blood for steady-state free precession imaging.
Saved in:
| Title: | Oxygen-sensitive contrast in blood for steady-state free precession imaging. |
|---|---|
| Authors: | Dharmakumar, Rohan1,2, Hong, Juimiin1, Brittain, Jean H.3, Plewes, Donald B.1, Wright, Graham A.1,2 |
| Source: | Magnetic Resonance in Medicine. Mar2005, Vol. 53 Issue 3, p574-583. 10p. |
| Abstract: | Steady-state free precession (SSFP) methods have gained widespread recognition for their ability to provide fast scans at high signal-to-noise ratio. This paper demonstrates that such methods are also capable of reflecting functional information, particularly blood oxygenation state. It is well known that SSFP signals show substantial sensitivity to small off-resonance frequency variations. However, that mechanism cannot explain the oxygen-sensitive contrast in blood that was observed with steady-state methods using phase-cycled radiofrequency pulses. From theoretical and experimental models it is demonstrated that the mechanism responsible for such contrast originates from the motion of spins through local field inhomogeneities in and around deoxygenated red blood cells. In addition, this work shows that it is critical to choose the scan parameters carefully for robust oxygen-sensitive contrast. Finally, it is demonstrated that it is possible to build a quantitative model that incorporates the Luz-Meiboom model, which had been used in the past to estimate quantitative measures of vascular blood oxygen levels. It is envisioned that this method could be instrumental in real-time imaging focused on detecting diseases where the oxygen state of blood is impaired. Magn Reson Med 53:574-583, 2005. © 2005 Wiley-Liss, Inc. [ABSTRACT FROM AUTHOR] |
| Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 63346182 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Oxygen-sensitive contrast in blood for steady-state free precession imaging. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Dharmakumar%2C+Rohan%22">Dharmakumar, Rohan</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Hong%2C+Juimiin%22">Hong, Juimiin</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Brittain%2C+Jean+H%2E%22">Brittain, Jean H.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Plewes%2C+Donald+B%2E%22">Plewes, Donald B.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Wright%2C+Graham+A%2E%22">Wright, Graham A.</searchLink><relatesTo>1,2</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Magnetic+Resonance+in+Medicine%22">Magnetic Resonance in Medicine</searchLink>. Mar2005, Vol. 53 Issue 3, p574-583. 10p. – Name: Abstract Label: Abstract Group: Ab Data: Steady-state free precession (SSFP) methods have gained widespread recognition for their ability to provide fast scans at high signal-to-noise ratio. This paper demonstrates that such methods are also capable of reflecting functional information, particularly blood oxygenation state. It is well known that SSFP signals show substantial sensitivity to small off-resonance frequency variations. However, that mechanism cannot explain the oxygen-sensitive contrast in blood that was observed with steady-state methods using phase-cycled radiofrequency pulses. From theoretical and experimental models it is demonstrated that the mechanism responsible for such contrast originates from the motion of spins through local field inhomogeneities in and around deoxygenated red blood cells. In addition, this work shows that it is critical to choose the scan parameters carefully for robust oxygen-sensitive contrast. Finally, it is demonstrated that it is possible to build a quantitative model that incorporates the Luz-Meiboom model, which had been used in the past to estimate quantitative measures of vascular blood oxygen levels. It is envisioned that this method could be instrumental in real-time imaging focused on detecting diseases where the oxygen state of blood is impaired. Magn Reson Med 53:574-583, 2005. © 2005 Wiley-Liss, Inc. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=63346182 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/mrm.20393 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 574 Titles: – TitleFull: Oxygen-sensitive contrast in blood for steady-state free precession imaging. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Dharmakumar, Rohan – PersonEntity: Name: NameFull: Hong, Juimiin – PersonEntity: Name: NameFull: Brittain, Jean H. – PersonEntity: Name: NameFull: Plewes, Donald B. – PersonEntity: Name: NameFull: Wright, Graham A. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 03 Text: Mar2005 Type: published Y: 2005 Identifiers: – Type: issn-print Value: 07403194 Numbering: – Type: volume Value: 53 – Type: issue Value: 3 Titles: – TitleFull: Magnetic Resonance in Medicine Type: main |
| ResultId | 1 |