Bibliographic Details
| Title: |
Dual-channel spectral subtraction algorithms based speech enhancement dedicated to a bilateral cochlear implant |
| Authors: |
Kallel, Fathi1,2 fathikallel@yahoo.fr, Frikha, Mondher1, Ghorbel, Mohamed1, Hamida, Ahmed Ben1, Berger-Vachon, Christian2 |
| Source: |
Applied Acoustics. Jan2012, Vol. 73 Issue 1, p12-20. 9p. |
| Subjects: |
Cochlear implants, Signal-to-noise ratio, Algorithms, Speech perception, Estimation theory, Spectral energy distribution, Signal processing |
| Abstract: |
Abstract: In this paper, two speech enhancement algorithms (SEAs) based on spectral subtraction (SS) principle have been evaluated for bilateral cochlear implant (BCI) users. Specifically, dual-channel noise power spectral estimation algorithm using power spectral densities (PSD) and cross power spectral density (CPSD) of the observed signals was studied. The enhanced speech signals were obtained using either Dual Channel Non Linear Spectral Subtraction ‘DC-NLSS’ or Dual-Channel Multi-Band Spectral Subtraction ‘DC-MBSS’ algorithms. For performance evaluation, some objective speech assessment tests relying on Perceptual Evaluation of Speech Quality (PESQ) score and speech Itakura-Saito (IS) distortion measurement were performed to fix the optimal number of frequency band needed in DC-MBSS algorithm. In order to evaluate the speech intelligibility, subjective listening tests were assessed with 50 normal hearing listeners using a specific BCI simulator and with three deafened BCI patients. Experimental results, obtained using French Lafon database corrupted by an additive babble noise at different Signal-to-Noise Ratios (SNR), showed that DC-MBSS algorithm improves speech understanding better than DC-NLSS algorithm for single and multiple interfering noise sources. [Copyright &y& Elsevier] |
|
Copyright of Applied Acoustics is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
Engineering Source |