Simultaneous determination of the azoles voriconazole, posaconazole, isavuconazole, itraconazole and its metabolite hydroxy-itraconazole in human plasma by reversed phase ultra-performance liquid chromatography with ultraviolet detection
Saved in:
| Title: | Simultaneous determination of the azoles voriconazole, posaconazole, isavuconazole, itraconazole and its metabolite hydroxy-itraconazole in human plasma by reversed phase ultra-performance liquid chromatography with ultraviolet detection |
|---|---|
| Authors: | Verweij-van Wissen, C.P.W.G.M.1,2 C.Verweij@akf.umcn.nl, Burger, D.M.1,2, Verweij, P.E.2,3, Aarnoutse, R.E.1,2, Brüggemann, R.J.M.1,2 |
| Source: | Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences. Mar2012, Vol. 887-888, p79-84. 6p. |
| Subjects: | Azoles, High performance liquid chromatography, Blood plasma, Ultraviolet detectors, Liquid-liquid extraction, Metabolites, Quantitative chemical analysis, Drug monitoring, Pharmacokinetics |
| Abstract: | Abstract: A reversed phase ultra-performance liquid chromatography method was developed for the simultaneous quantitative determination of the systemically administered azoles voriconazole, posaconazole, isavuconazole, itraconazole and its metabolite hydroxy-itraconazole in plasma. The method involved a simple liquid–liquid extraction followed by ultra-performance liquid chromatography with an Acquity UPLC BEH Phenyl column and ultraviolet detection set at a wavelength of 260nm. The assay was validated over the concentration range of 0.050–10,000mg/l for all four azoles and one metabolite. The accuracies for the assay were 97–104%, inter- and intra-day coefficients of variation were <7.5% and extraction recoveries were 98% for voriconazole, posaconazole, isavuconazole and the internal standard (UK115794), and 79% and 88% for itraconazole and hydroxy-itraconazole respectively. This method proved to be simple, accurate, precise and fast and is currently in use in our laboratory for the quantitative analysis of these azoles for Therapeutic Drug Monitoring and pharmacokinetic research. [Copyright &y& Elsevier] |
| Copyright of Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 71952393 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Simultaneous determination of the azoles voriconazole, posaconazole, isavuconazole, itraconazole and its metabolite hydroxy-itraconazole in human plasma by reversed phase ultra-performance liquid chromatography with ultraviolet detection – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Verweij-van+Wissen%2C+C%2EP%2EW%2EG%2EM%2E%22">Verweij-van Wissen, C.P.W.G.M.</searchLink><relatesTo>1,2</relatesTo><i> C.Verweij@akf.umcn.nl</i><br /><searchLink fieldCode="AR" term="%22Burger%2C+D%2EM%2E%22">Burger, D.M.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Verweij%2C+P%2EE%2E%22">Verweij, P.E.</searchLink><relatesTo>2,3</relatesTo><br /><searchLink fieldCode="AR" term="%22Aarnoutse%2C+R%2EE%2E%22">Aarnoutse, R.E.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Brüggemann%2C+R%2EJ%2EM%2E%22">Brüggemann, R.J.M.</searchLink><relatesTo>1,2</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Journal+of+Chromatography+B%3A+Analytical+Technologies+in+the+Biomedical+%26+Life+Sciences%22">Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences</searchLink>. Mar2012, Vol. 887-888, p79-84. 6p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Azoles%22">Azoles</searchLink><br /><searchLink fieldCode="DE" term="%22High+performance+liquid+chromatography%22">High performance liquid chromatography</searchLink><br /><searchLink fieldCode="DE" term="%22Blood+plasma%22">Blood plasma</searchLink><br /><searchLink fieldCode="DE" term="%22Ultraviolet+detectors%22">Ultraviolet detectors</searchLink><br /><searchLink fieldCode="DE" term="%22Liquid-liquid+extraction%22">Liquid-liquid extraction</searchLink><br /><searchLink fieldCode="DE" term="%22Metabolites%22">Metabolites</searchLink><br /><searchLink fieldCode="DE" term="%22Quantitative+chemical+analysis%22">Quantitative chemical analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Drug+monitoring%22">Drug monitoring</searchLink><br /><searchLink fieldCode="DE" term="%22Pharmacokinetics%22">Pharmacokinetics</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Abstract: A reversed phase ultra-performance liquid chromatography method was developed for the simultaneous quantitative determination of the systemically administered azoles voriconazole, posaconazole, isavuconazole, itraconazole and its metabolite hydroxy-itraconazole in plasma. The method involved a simple liquid–liquid extraction followed by ultra-performance liquid chromatography with an Acquity UPLC BEH Phenyl column and ultraviolet detection set at a wavelength of 260nm. The assay was validated over the concentration range of 0.050–10,000mg/l for all four azoles and one metabolite. The accuracies for the assay were 97–104%, inter- and intra-day coefficients of variation were <7.5% and extraction recoveries were 98% for voriconazole, posaconazole, isavuconazole and the internal standard (UK115794), and 79% and 88% for itraconazole and hydroxy-itraconazole respectively. This method proved to be simple, accurate, precise and fast and is currently in use in our laboratory for the quantitative analysis of these azoles for Therapeutic Drug Monitoring and pharmacokinetic research. [Copyright &y& Elsevier] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=71952393 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.jchromb.2012.01.015 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 6 StartPage: 79 Subjects: – SubjectFull: Azoles Type: general – SubjectFull: High performance liquid chromatography Type: general – SubjectFull: Blood plasma Type: general – SubjectFull: Ultraviolet detectors Type: general – SubjectFull: Liquid-liquid extraction Type: general – SubjectFull: Metabolites Type: general – SubjectFull: Quantitative chemical analysis Type: general – SubjectFull: Drug monitoring Type: general – SubjectFull: Pharmacokinetics Type: general Titles: – TitleFull: Simultaneous determination of the azoles voriconazole, posaconazole, isavuconazole, itraconazole and its metabolite hydroxy-itraconazole in human plasma by reversed phase ultra-performance liquid chromatography with ultraviolet detection Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Verweij-van Wissen, C.P.W.G.M. – PersonEntity: Name: NameFull: Burger, D.M. – PersonEntity: Name: NameFull: Verweij, P.E. – PersonEntity: Name: NameFull: Aarnoutse, R.E. – PersonEntity: Name: NameFull: Brüggemann, R.J.M. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 03 Text: Mar2012 Type: published Y: 2012 Identifiers: – Type: issn-print Value: 15700232 Numbering: – Type: volume Value: 887-888 Titles: – TitleFull: Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences Type: main |
| ResultId | 1 |