Four Channel, 40 ps Resolution, Fully Integrated Time-to-Amplitude Converter for Time-Resolved Photon Counting.

Saved in:
Bibliographic Details
Title: Four Channel, 40 ps Resolution, Fully Integrated Time-to-Amplitude Converter for Time-Resolved Photon Counting.
Authors: Crotti, Matteo1, Rech, Ivan1, Ghioni, Massimo1
Source: IEEE Journal of Solid-State Circuits. Mar2012, Vol. 47 Issue 3, p699-708. 10p.
Subjects: Photons, Time-resolved spectroscopy, Single photon emission computerized tomography centers, Wave analysis, High resolution imaging, Energy dissipation, Time measurements, Photonics, Bandwidths
Abstract: Recently, a growing interest has arisen about the time-correlated single photon counting (TCSPC) technique, that allows the analysis of fast and weak light waveforms with a time resolution in the picosecond order. Since TCSPC basically consists of the measurement of the arrival time of a photon, a high resolution and high linearity time measurement block is of the utmost importance; moreover, the use of multianode Photo Multiplier Tube and of single photon avalanche diode arrays led to the development of multichannel acquisition systems, where the time measurement block has to be integrated to reduce both cost and area. We have designed and fabricated a four channel fully integrated time-to-amplitude converter (TAC), built in 0.35 \mum Si-Ge technology, characterized by an excellent time resolution (less than 50 ps full width half maximum), low differential nonlinearity (better than 0.02 LSB peak-peak and 0.0003 LSB rms), high counting rate (16 MHz), low and constant power dissipation (50 mW) and low area occupation (2.58\,\times\,1.28 mm^2). Moreover, the very low crosstalk (-115 dB) between channels, together with low power and low area makes the converter suitable for large scale multi-channel acquisition chains. [ABSTRACT FROM AUTHOR]
Copyright of IEEE Journal of Solid-State Circuits is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Be the first to leave a comment!