Comparison of topogram-based body size indices for CT dose consideration and scan protocol optimization.

Saved in:
Bibliographic Details
Title: Comparison of topogram-based body size indices for CT dose consideration and scan protocol optimization.
Authors: Li, Baojun1, Behrman, Richard H.1, Norbash, Alexander M.1
Source: Medical Physics. Jun2012, Vol. 39 Issue 6, p3456-3465. 10p.
Subjects: Body size, Tomography, Medical protocols, Mathematical optimization, Retrospective studies, Confidence intervals, Measurement errors, Parameter estimation
Abstract: Purpose: To retrospectively compare different topogram-based patient body size indices and to determine the optimal topogram-based body size index as a basis for body computed tomography (CT) dose consideration and scan protocol optimization. Methods: Forty-three routine thorax and abdomen CT scans are studied retrospectively, with patient ages ranging from 18 to 67 yr. The individual patient's water-equivalent diameter (Dw) of the scanned body region is computed from CT DICOM images as the 'gold standard,' after first converting from Hounsfield units values to μa values, where μ is the normalized tissue attenuation coefficient and a is the area per pixel. Four topogram-based body size indices [average diameter [formula], girth (G), topogram projection area (Etopo), and improved topogram projection area (Etopo')] are computed and correlated with Dw using linear regression analysis. Specifically, D is calculated by averaging the coronal and sagittal diameters; G is computed by modeling the patient's cross-section as an ellipse; Etopo is the product of the mean topogram pixel value and the width of the scanned body region; and (Etopo') incorporates Etopo with correction of patient miscentering and water attenuation coefficient. The accuracy of these four approaches for estimation of Dw is assessed using linear regression models. Results are given in terms of 95% confidence intervals (CIs). Results: Regression analysis results in four different linear models. The standard error (95% CI) for estimation of Dw from D and G was ±2.8 and ±3.1 cm, respectively (p = 0.297). The standard error for estimation of Dw from Etopo was significantly less than that from D (±2.1 cm, p < 0.01). The standard error for estimation of Dw from (Etopo') was ±1.3 cm, significantly less than that from Etopo (p < 0.01). Conclusions: Among the four topogram-based patient body indices, (Etopo') is the most accurate for estimation of individual x-ray attenuation of the scanned body region. Thus, (Etopo') is an optimal topogram-based patient body size index that is relevant for determining the proper CT dose level for individual patients. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 77399500
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Comparison of topogram-based body size indices for CT dose consideration and scan protocol optimization.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Li%2C+Baojun%22&quot;&gt;Li, Baojun&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Behrman%2C+Richard+H%2E%22&quot;&gt;Behrman, Richard H.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Norbash%2C+Alexander+M%2E%22&quot;&gt;Norbash, Alexander M.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Medical+Physics%22&quot;&gt;Medical Physics&lt;/searchLink&gt;. Jun2012, Vol. 39 Issue 6, p3456-3465. 10p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Body+size%22&quot;&gt;Body size&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Tomography%22&quot;&gt;Tomography&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Medical+protocols%22&quot;&gt;Medical protocols&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Mathematical+optimization%22&quot;&gt;Mathematical optimization&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Retrospective+studies%22&quot;&gt;Retrospective studies&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Confidence+intervals%22&quot;&gt;Confidence intervals&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Measurement+errors%22&quot;&gt;Measurement errors&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Parameter+estimation%22&quot;&gt;Parameter estimation&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: To retrospectively compare different topogram-based patient body size indices and to determine the optimal topogram-based body size index as a basis for body computed tomography (CT) dose consideration and scan protocol optimization. Methods: Forty-three routine thorax and abdomen CT scans are studied retrospectively, with patient ages ranging from 18 to 67 yr. The individual patient&#39;s water-equivalent diameter (Dw) of the scanned body region is computed from CT DICOM images as the &#39;gold standard,&#39; after first converting from Hounsfield units values to μa values, where μ is the normalized tissue attenuation coefficient and a is the area per pixel. Four topogram-based body size indices [average diameter [formula], girth (G), topogram projection area (Etopo), and improved topogram projection area (Etopo&#39;)] are computed and correlated with Dw using linear regression analysis. Specifically, &lt;OVERLINE&gt;D&lt;/OVERLINE&gt; is calculated by averaging the coronal and sagittal diameters; G is computed by modeling the patient&#39;s cross-section as an ellipse; Etopo is the product of the mean topogram pixel value and the width of the scanned body region; and (Etopo&#39;) incorporates Etopo with correction of patient miscentering and water attenuation coefficient. The accuracy of these four approaches for estimation of Dw is assessed using linear regression models. Results are given in terms of 95% confidence intervals (CIs). Results: Regression analysis results in four different linear models. The standard error (95% CI) for estimation of Dw from &lt;OVERLINE&gt;D&lt;/OVERLINE&gt; and G was &#177;2.8 and &#177;3.1 cm, respectively (p = 0.297). The standard error for estimation of Dw from Etopo was significantly less than that from &lt;OVERLINE&gt;D&lt;/OVERLINE&gt; (&#177;2.1 cm, p &lt; 0.01). The standard error for estimation of Dw from (Etopo&#39;) was &#177;1.3 cm, significantly less than that from Etopo (p &lt; 0.01). Conclusions: Among the four topogram-based patient body indices, (Etopo&#39;) is the most accurate for estimation of individual x-ray attenuation of the scanned body region. Thus, (Etopo&#39;) is an optimal topogram-based patient body size index that is relevant for determining the proper CT dose level for individual patients. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=77399500
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1118/1.4718569
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 3456
    Subjects:
      – SubjectFull: Body size
        Type: general
      – SubjectFull: Tomography
        Type: general
      – SubjectFull: Medical protocols
        Type: general
      – SubjectFull: Mathematical optimization
        Type: general
      – SubjectFull: Retrospective studies
        Type: general
      – SubjectFull: Confidence intervals
        Type: general
      – SubjectFull: Measurement errors
        Type: general
      – SubjectFull: Parameter estimation
        Type: general
    Titles:
      – TitleFull: Comparison of topogram-based body size indices for CT dose consideration and scan protocol optimization.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Li, Baojun
      – PersonEntity:
          Name:
            NameFull: Behrman, Richard H.
      – PersonEntity:
          Name:
            NameFull: Norbash, Alexander M.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2012
              Type: published
              Y: 2012
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 39
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1