Voxel-wise uncertainty in CT substitute derived from MRI.

Saved in:
Bibliographic Details
Title: Voxel-wise uncertainty in CT substitute derived from MRI.
Authors: Johansson, Adam1, Karlsson, Mikael1, Yu, Jun2, Asklund, Thomas1, Nyholm, Tufve1
Source: Medical Physics. Jun2012, Vol. 39 Issue 6, p3283-3290. 8p.
Subjects: Tomography, Magnetic resonance imaging, Finite Gaussian mixture models (Statistics), Medical imaging systems, Uncertainty (Information theory), Parameter estimation, Mathematical models
Abstract: Purpose: In an earlier work, we demonstrated that substitutes for CT images can be derived from MR images using ultrashort echo time (UTE) sequences, conventional T2 weighted sequences, and Gaussian mixture regression (GMR). In this study, we extend this work by analyzing the uncertainties associated with the GMR model and the information contributions from the individual imaging sequences. Methods: An analytical expression for the voxel-wise conditional expected absolute deviation (EAD) in substitute CT (s-CT) images was derived. The expression depends only on MR images and can thus be calculated along with each s-CT image. The uncertainty measure was evaluated by comparing the EAD to the true mean absolute prediction deviation (MAPD) between the s-CT and CT images for 14 patients. Further, the influence of the different MR images included in the GMR model on the generated s-CTs was investigated by removing one or more images and evaluating the MAPD for a spectrum of predicted radiological densities. Results: The largest EAD was predicted at air-soft tissue and bone-soft tissue interfaces. The EAD agreed with the MAPD in both these regions and in regions with lower EADs, such as the brain. Two of the MR images included in the GMR model were found to be mutually redundant for the purpose of s-CT generation. Conclusions: The presented uncertainty estimation method accurately predicts the voxel-wise MAPD in s-CT images. Also, the non-UTE sequence previously used in the model was found to be redundant. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 77399512
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Voxel-wise uncertainty in CT substitute derived from MRI.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Johansson%2C+Adam%22">Johansson, Adam</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Karlsson%2C+Mikael%22">Karlsson, Mikael</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Yu%2C+Jun%22">Yu, Jun</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Asklund%2C+Thomas%22">Asklund, Thomas</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Nyholm%2C+Tufve%22">Nyholm, Tufve</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Jun2012, Vol. 39 Issue 6, p3283-3290. 8p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Tomography%22">Tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Magnetic+resonance+imaging%22">Magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Finite+Gaussian+mixture+models+%28Statistics%29%22">Finite Gaussian mixture models (Statistics)</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+imaging+systems%22">Medical imaging systems</searchLink><br /><searchLink fieldCode="DE" term="%22Uncertainty+%28Information+theory%29%22">Uncertainty (Information theory)</searchLink><br /><searchLink fieldCode="DE" term="%22Parameter+estimation%22">Parameter estimation</searchLink><br /><searchLink fieldCode="DE" term="%22Mathematical+models%22">Mathematical models</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: In an earlier work, we demonstrated that substitutes for CT images can be derived from MR images using ultrashort echo time (UTE) sequences, conventional T2 weighted sequences, and Gaussian mixture regression (GMR). In this study, we extend this work by analyzing the uncertainties associated with the GMR model and the information contributions from the individual imaging sequences. Methods: An analytical expression for the voxel-wise conditional expected absolute deviation (EAD) in substitute CT (s-CT) images was derived. The expression depends only on MR images and can thus be calculated along with each s-CT image. The uncertainty measure was evaluated by comparing the EAD to the true mean absolute prediction deviation (MAPD) between the s-CT and CT images for 14 patients. Further, the influence of the different MR images included in the GMR model on the generated s-CTs was investigated by removing one or more images and evaluating the MAPD for a spectrum of predicted radiological densities. Results: The largest EAD was predicted at air-soft tissue and bone-soft tissue interfaces. The EAD agreed with the MAPD in both these regions and in regions with lower EADs, such as the brain. Two of the MR images included in the GMR model were found to be mutually redundant for the purpose of s-CT generation. Conclusions: The presented uncertainty estimation method accurately predicts the voxel-wise MAPD in s-CT images. Also, the non-UTE sequence previously used in the model was found to be redundant. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=77399512
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1118/1.4711807
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 3283
    Subjects:
      – SubjectFull: Tomography
        Type: general
      – SubjectFull: Magnetic resonance imaging
        Type: general
      – SubjectFull: Finite Gaussian mixture models (Statistics)
        Type: general
      – SubjectFull: Medical imaging systems
        Type: general
      – SubjectFull: Uncertainty (Information theory)
        Type: general
      – SubjectFull: Parameter estimation
        Type: general
      – SubjectFull: Mathematical models
        Type: general
    Titles:
      – TitleFull: Voxel-wise uncertainty in CT substitute derived from MRI.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Johansson, Adam
      – PersonEntity:
          Name:
            NameFull: Karlsson, Mikael
      – PersonEntity:
          Name:
            NameFull: Yu, Jun
      – PersonEntity:
          Name:
            NameFull: Asklund, Thomas
      – PersonEntity:
          Name:
            NameFull: Nyholm, Tufve
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2012
              Type: published
              Y: 2012
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 39
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1