Reliability of two calculation codes for efficiency calibrations of HPGe detectors

Saved in:
Bibliographic Details
Title: Reliability of two calculation codes for efficiency calibrations of HPGe detectors
Authors: Abbas, K. kamel.abbas@jrc.it, Simonelli, F.1, D’Alberti, F.1, Forte, M.1, Stroosnijder, M.F.1
Source: Applied Radiation & Isotopes. May2002, Vol. 56 Issue 5, p703. 7p.
Subjects: Calibration, Gamma rays
Abstract: This paper reports the reliability of efficiency calibrations for γ-ray detectors using the calculation codes ANGLE and LabSOCS. For experimental verification, three HPGe detectors under various laboratory geometry configurations were used for this study. An overall comparison between experimental and calculated efficiency calibration curves is presented and comments on the various error sources affecting the final results are given. The deviations are generally below 10%, which could be acceptable for many applications. [Copyright &y& Elsevier]
Copyright of Applied Radiation & Isotopes is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 7767435
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Reliability of two calculation codes for efficiency calibrations of HPGe detectors
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Abbas%2C+K%2E%22">Abbas, K.</searchLink><i> kamel.abbas@jrc.it</i><br /><searchLink fieldCode="AR" term="%22Simonelli%2C+F%2E%22">Simonelli, F.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22D’Alberti%2C+F%2E%22">D’Alberti, F.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Forte%2C+M%2E%22">Forte, M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Stroosnijder%2C+M%2EF%2E%22">Stroosnijder, M.F.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Applied+Radiation+%26+Isotopes%22">Applied Radiation & Isotopes</searchLink>. May2002, Vol. 56 Issue 5, p703. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Calibration%22">Calibration</searchLink><br /><searchLink fieldCode="DE" term="%22Gamma+rays%22">Gamma rays</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: This paper reports the reliability of efficiency calibrations for <f>γ</f>-ray detectors using the calculation codes ANGLE and LabSOCS. For experimental verification, three HPGe detectors under various laboratory geometry configurations were used for this study. An overall comparison between experimental and calculated efficiency calibration curves is presented and comments on the various error sources affecting the final results are given. The deviations are generally below 10%, which could be acceptable for many applications. [Copyright &y& Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Applied Radiation & Isotopes is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=7767435
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/S0969-8043(01)00269-X
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 703
    Subjects:
      – SubjectFull: Calibration
        Type: general
      – SubjectFull: Gamma rays
        Type: general
    Titles:
      – TitleFull: Reliability of two calculation codes for efficiency calibrations of HPGe detectors
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Abbas, K.
      – PersonEntity:
          Name:
            NameFull: Simonelli, F.
      – PersonEntity:
          Name:
            NameFull: D’Alberti, F.
      – PersonEntity:
          Name:
            NameFull: Forte, M.
      – PersonEntity:
          Name:
            NameFull: Stroosnijder, M.F.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Text: May2002
              Type: published
              Y: 2002
          Identifiers:
            – Type: issn-print
              Value: 09698043
          Numbering:
            – Type: volume
              Value: 56
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: Applied Radiation & Isotopes
              Type: main
ResultId 1