Comparing contrast-enhanced ultrasound to immunohistochemical markers of angiogenesis in a human melanoma xenograft model: preliminary results
Saved in:
| Title: | Comparing contrast-enhanced ultrasound to immunohistochemical markers of angiogenesis in a human melanoma xenograft model: preliminary results |
|---|---|
| Authors: | Forsberg, Flemming1 forsberg@esther.rad.tju.edu, Dicker, Adam P.2, Thakur, Mattew L.1, Rawool, Nandkumar M.1, Liu, Ji-bin1, Shi, William T.1, Nazarian, Levon N.1 |
| Source: | Ultrasound in Medicine & Biology. Apr2002, Vol. 28 Issue 4, p445-451. 7p. |
| Subjects: | Melanoma, Neovascularization, Diagnostic ultrasonic imaging |
| Abstract: | This study compared contrast-enhanced ultrasound (US) measures of tumor neovascularity with molecular markers of angiogenesis in a human melanoma xenograft model. A total of 14 mice were implanted with a human melanoma cell line (WM-9) in the thigh. After 2 to 3 weeks, a tumor, approximately 12 mm in diameter, developed. The US contrast agent Optison® (Mallinckrodt, St. Louis, MO) was injected in a tail vein (dose: 0.4 to 0.6 mL/kg). Power Doppler and pulse-inversion harmonic imaging (HI) were performed with an Elegra scanner (Siemens Medical Systems, Issaquah, WA) and a 7.5 MHz linear array. Frame-rates of 30 Hz and 0.5 Hz (intermittent imaging) were used for pulse-inversion HI. After surgical removal, specimens were sectioned in the same planes as the US images. Immunohistochemical stains for endothelial cells (CD31), vascular endothelial growth factor (VEGF), basic fibroblast growth factor (bFGF) and cyclooxygenase-2 (COX-2) were performed. Two observers graded the stains (for intensity and percent area), and two other observers graded the US imaging modes (for fractional tumor neovascularity) on the same scale from 0 to 3. Of the 14 mice, 4 failed for technical reasons (i.e., n = 10). Linear regressions indicated statistically significant correlations between percent area stained with COX-2 and power Doppler (r = −0.789; p < 0.01), as well as intermittent pulse-inversion HI (r = −0.795; p < 0.05). There was a trend toward significance between percent area stained with VEGF and intermittent pulse-inversion HI (r = −0.720; 0.05 < p < 0.10). No other comparisons were significant. In conclusion, contrast-enhanced US measures of tumor neovascularity in a human melanoma xenograft model appear to provide a noninvasive marker of angiogenesis corresponding to expression of COX-2. However, the sample size of this study is small and, until further studies have been conducted, these conclusions are preliminary. (E-mail:forsberg@esther.rad.tju.edu) [Copyright &y& Elsevier] |
| Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 7818883 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Comparing contrast-enhanced ultrasound to immunohistochemical markers of angiogenesis in a human melanoma xenograft model: preliminary results – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Forsberg%2C+Flemming%22">Forsberg, Flemming</searchLink><relatesTo>1</relatesTo><i> forsberg@esther.rad.tju.edu</i><br /><searchLink fieldCode="AR" term="%22Dicker%2C+Adam+P%2E%22">Dicker, Adam P.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Thakur%2C+Mattew+L%2E%22">Thakur, Mattew L.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Rawool%2C+Nandkumar+M%2E%22">Rawool, Nandkumar M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Liu%2C+Ji-bin%22">Liu, Ji-bin</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Shi%2C+William+T%2E%22">Shi, William T.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Nazarian%2C+Levon+N%2E%22">Nazarian, Levon N.</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Ultrasound+in+Medicine+%26+Biology%22">Ultrasound in Medicine & Biology</searchLink>. Apr2002, Vol. 28 Issue 4, p445-451. 7p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Melanoma%22">Melanoma</searchLink><br /><searchLink fieldCode="DE" term="%22Neovascularization%22">Neovascularization</searchLink><br /><searchLink fieldCode="DE" term="%22Diagnostic+ultrasonic+imaging%22">Diagnostic ultrasonic imaging</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: This study compared contrast-enhanced ultrasound (US) measures of tumor neovascularity with molecular markers of angiogenesis in a human melanoma xenograft model. A total of 14 mice were implanted with a human melanoma cell line (WM-9) in the thigh. After 2 to 3 weeks, a tumor, approximately 12 mm in diameter, developed. The US contrast agent Optison® (Mallinckrodt, St. Louis, MO) was injected in a tail vein (dose: 0.4 to 0.6 mL/kg). Power Doppler and pulse-inversion harmonic imaging (HI) were performed with an Elegra scanner (Siemens Medical Systems, Issaquah, WA) and a 7.5 MHz linear array. Frame-rates of 30 Hz and 0.5 Hz (intermittent imaging) were used for pulse-inversion HI. After surgical removal, specimens were sectioned in the same planes as the US images. Immunohistochemical stains for endothelial cells (CD31), vascular endothelial growth factor (VEGF), basic fibroblast growth factor (bFGF) and cyclooxygenase-2 (COX-2) were performed. Two observers graded the stains (for intensity and percent area), and two other observers graded the US imaging modes (for fractional tumor neovascularity) on the same scale from 0 to 3. Of the 14 mice, 4 failed for technical reasons (i.e., n = 10). Linear regressions indicated statistically significant correlations between percent area stained with COX-2 and power Doppler (r = −0.789; p < 0.01), as well as intermittent pulse-inversion HI (r = −0.795; p < 0.05). There was a trend toward significance between percent area stained with VEGF and intermittent pulse-inversion HI (r = −0.720; 0.05 < p < 0.10). No other comparisons were significant. In conclusion, contrast-enhanced US measures of tumor neovascularity in a human melanoma xenograft model appear to provide a noninvasive marker of angiogenesis corresponding to expression of COX-2. However, the sample size of this study is small and, until further studies have been conducted, these conclusions are preliminary. (E-mail:forsberg@esther.rad.tju.edu) [Copyright &y& Elsevier] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=7818883 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/S0301-5629(02)00482-9 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 7 StartPage: 445 Subjects: – SubjectFull: Melanoma Type: general – SubjectFull: Neovascularization Type: general – SubjectFull: Diagnostic ultrasonic imaging Type: general Titles: – TitleFull: Comparing contrast-enhanced ultrasound to immunohistochemical markers of angiogenesis in a human melanoma xenograft model: preliminary results Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Forsberg, Flemming – PersonEntity: Name: NameFull: Dicker, Adam P. – PersonEntity: Name: NameFull: Thakur, Mattew L. – PersonEntity: Name: NameFull: Rawool, Nandkumar M. – PersonEntity: Name: NameFull: Liu, Ji-bin – PersonEntity: Name: NameFull: Shi, William T. – PersonEntity: Name: NameFull: Nazarian, Levon N. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 04 Text: Apr2002 Type: published Y: 2002 Identifiers: – Type: issn-print Value: 03015629 Numbering: – Type: volume Value: 28 – Type: issue Value: 4 Titles: – TitleFull: Ultrasound in Medicine & Biology Type: main |
| ResultId | 1 |