Automated clarity assessment of retinal images using regionally based structural and statistical measures

Saved in:
Bibliographic Details
Title: Automated clarity assessment of retinal images using regionally based structural and statistical measures
Authors: Fleming, Alan D.1 a.fleming@abdn.ac.uk, Philip, Sam2, Goatman, Keith A.1, Sharp, Peter F.1, Olson, John A.2
Source: Medical Engineering & Physics. Sep2012, Vol. 34 Issue 7, p849-859. 11p.
Subjects: Retina, Image analysis, Medical statistics, Medical screening, Diabetic retinopathy, Photographs
Abstract: Abstract: An automated image analysis system for application in mass medical screening must assess the clarity of the images before analysing their content. This is the case in grading for diabetic retinopathy screening where the failure to assess clarity could result in retinal images of people with retinopathy being erroneously classed as normal. This paper compares methods of clarity assessment based on the degradation of visible structures and based on the deviation of image properties outside expected norms caused by clarity loss. Vessel visibility measures and statistical measures were determined at locations in the image which have high saliency and these were used to obtain an image clarity assessment using supervised classification. The usefulness of the measures as indicators of image clarity was assessed. Tests were performed on 987 disc-centred and macula-centred retinal photographs (347 with inadequate clarity) obtained from the English National Screening Programme. Images with inadequate clarity were detected with 92.6% sensitivity at 90% specificity. In a set of 2000 macula-centred images (200 with inadequate clarity) from the Scottish Screening Programme, inadequate clarity was detected with 96.7% sensitivity at 90% specificity. This study has shown that structural and statistical measures are equally useful for retinal image clarity assessment. [Copyright &y& Elsevier]
Copyright of Medical Engineering & Physics is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Be the first to leave a comment!
You must be logged in first