Investigating the Efficacy of Subharmonic Aided Pressure Estimation for Portal Vein Pressures and Portal Hypertension Monitoring
Saved in:
| Title: | Investigating the Efficacy of Subharmonic Aided Pressure Estimation for Portal Vein Pressures and Portal Hypertension Monitoring |
|---|---|
| Authors: | Dave, Jaydev K.1,2, Halldorsdottir, Valgerdur G.1,2, Eisenbrey, John R.1, Merton, Daniel A.1, Liu, Ji-Bin1, Zhou, Jian-Hua1, Wang, Hsin-Kai1, Park, Suhyun3, Dianis, Scott3, Chalek, Carl L.3, Lin, Feng3, Thomenius, Kai E.3, Brown, Daniel B.1, Forsberg, Flemming1 flemming.forsberg@jefferson.edu |
| Source: | Ultrasound in Medicine & Biology. Oct2012, Vol. 38 Issue 10, p1784-1798. 15p. |
| Subjects: | Portal vein, Portal hypertension, Microbubbles, Subharmonic functions, Blood pressure measurement, Cuspids, Catheterization |
| Abstract: | Abstract: The efficacy of using subharmonic emissions from Sonazoid microbubbles (GE Healthcare, Oslo, Norway) to track portal vein pressures and pressure changes was investigated in 14 canines using either slow- or high-flow models of portal hypertension (PH). A modified Logiq 9 scanner (GE Healthcare, Milwaukee, WI, USA) operating in subharmonic mode (ftransmit: 2.5 MHz, freceive: 1.25 MHz) was used to collect radiofrequency data at 10–40% incident acoustic power levels with 2–4 transmit cycles (in triplicate) before and after inducing PH. A pressure catheter (Millar Instruments, Inc., Houston, TX, USA) provided reference portal vein pressures. At optimum insonification, subharmonic signal amplitude changes correlated with portal vein pressure changes; r ranged from −0.82 to −0.94 and from −0.70 to −0.73 for PH models considered separately or together, respectively. The subharmonic signal amplitudes correlated with absolute portal vein pressures (r: −0.71 to −0.79). Statistically significant differences between subharmonic amplitudes, before and after inducing PH, were noted (p ≤ 0.01). Portal vein pressures estimated using subharmonic aided pressure estimation did not reveal significant differences (p > 0.05) with respect to the pressures obtained using the Millar pressure catheter. Subharmonic-aided pressure estimation may be useful clinically for portal vein pressure monitoring. [Copyright &y& Elsevier] |
| Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 79807000 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Investigating the Efficacy of Subharmonic Aided Pressure Estimation for Portal Vein Pressures and Portal Hypertension Monitoring – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Dave%2C+Jaydev+K%2E%22">Dave, Jaydev K.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Halldorsdottir%2C+Valgerdur+G%2E%22">Halldorsdottir, Valgerdur G.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Eisenbrey%2C+John+R%2E%22">Eisenbrey, John R.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Merton%2C+Daniel+A%2E%22">Merton, Daniel A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Liu%2C+Ji-Bin%22">Liu, Ji-Bin</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Zhou%2C+Jian-Hua%22">Zhou, Jian-Hua</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Wang%2C+Hsin-Kai%22">Wang, Hsin-Kai</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Park%2C+Suhyun%22">Park, Suhyun</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Dianis%2C+Scott%22">Dianis, Scott</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Chalek%2C+Carl+L%2E%22">Chalek, Carl L.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Lin%2C+Feng%22">Lin, Feng</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Thomenius%2C+Kai+E%2E%22">Thomenius, Kai E.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Brown%2C+Daniel+B%2E%22">Brown, Daniel B.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Forsberg%2C+Flemming%22">Forsberg, Flemming</searchLink><relatesTo>1</relatesTo><i> flemming.forsberg@jefferson.edu</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Ultrasound+in+Medicine+%26+Biology%22">Ultrasound in Medicine & Biology</searchLink>. Oct2012, Vol. 38 Issue 10, p1784-1798. 15p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Portal+vein%22">Portal vein</searchLink><br /><searchLink fieldCode="DE" term="%22Portal+hypertension%22">Portal hypertension</searchLink><br /><searchLink fieldCode="DE" term="%22Microbubbles%22">Microbubbles</searchLink><br /><searchLink fieldCode="DE" term="%22Subharmonic+functions%22">Subharmonic functions</searchLink><br /><searchLink fieldCode="DE" term="%22Blood+pressure+measurement%22">Blood pressure measurement</searchLink><br /><searchLink fieldCode="DE" term="%22Cuspids%22">Cuspids</searchLink><br /><searchLink fieldCode="DE" term="%22Catheterization%22">Catheterization</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Abstract: The efficacy of using subharmonic emissions from Sonazoid microbubbles (GE Healthcare, Oslo, Norway) to track portal vein pressures and pressure changes was investigated in 14 canines using either slow- or high-flow models of portal hypertension (PH). A modified Logiq 9 scanner (GE Healthcare, Milwaukee, WI, USA) operating in subharmonic mode (ftransmit: 2.5 MHz, freceive: 1.25 MHz) was used to collect radiofrequency data at 10–40% incident acoustic power levels with 2–4 transmit cycles (in triplicate) before and after inducing PH. A pressure catheter (Millar Instruments, Inc., Houston, TX, USA) provided reference portal vein pressures. At optimum insonification, subharmonic signal amplitude changes correlated with portal vein pressure changes; r ranged from −0.82 to −0.94 and from −0.70 to −0.73 for PH models considered separately or together, respectively. The subharmonic signal amplitudes correlated with absolute portal vein pressures (r: −0.71 to −0.79). Statistically significant differences between subharmonic amplitudes, before and after inducing PH, were noted (p ≤ 0.01). Portal vein pressures estimated using subharmonic aided pressure estimation did not reveal significant differences (p > 0.05) with respect to the pressures obtained using the Millar pressure catheter. Subharmonic-aided pressure estimation may be useful clinically for portal vein pressure monitoring. [Copyright &y& Elsevier] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=79807000 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.ultrasmedbio.2012.06.013 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 15 StartPage: 1784 Subjects: – SubjectFull: Portal vein Type: general – SubjectFull: Portal hypertension Type: general – SubjectFull: Microbubbles Type: general – SubjectFull: Subharmonic functions Type: general – SubjectFull: Blood pressure measurement Type: general – SubjectFull: Cuspids Type: general – SubjectFull: Catheterization Type: general Titles: – TitleFull: Investigating the Efficacy of Subharmonic Aided Pressure Estimation for Portal Vein Pressures and Portal Hypertension Monitoring Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Dave, Jaydev K. – PersonEntity: Name: NameFull: Halldorsdottir, Valgerdur G. – PersonEntity: Name: NameFull: Eisenbrey, John R. – PersonEntity: Name: NameFull: Merton, Daniel A. – PersonEntity: Name: NameFull: Liu, Ji-Bin – PersonEntity: Name: NameFull: Zhou, Jian-Hua – PersonEntity: Name: NameFull: Wang, Hsin-Kai – PersonEntity: Name: NameFull: Park, Suhyun – PersonEntity: Name: NameFull: Dianis, Scott – PersonEntity: Name: NameFull: Chalek, Carl L. – PersonEntity: Name: NameFull: Lin, Feng – PersonEntity: Name: NameFull: Thomenius, Kai E. – PersonEntity: Name: NameFull: Brown, Daniel B. – PersonEntity: Name: NameFull: Forsberg, Flemming IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: Oct2012 Type: published Y: 2012 Identifiers: – Type: issn-print Value: 03015629 Numbering: – Type: volume Value: 38 – Type: issue Value: 10 Titles: – TitleFull: Ultrasound in Medicine & Biology Type: main |
| ResultId | 1 |