Abstract: The article presents a study which analyzes and compares two types of implant fixation of human temporomandibular joint (TMJ )using commercial screws and the hypothetic intramedullary fixation. The study uses a three-dimensional (3D) finite element (FE) model and a computer-aided design (CAD) model of the implanted mandible. Results show the key role of the screw positions in the bone strain distribution.
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 80441419
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Implant fixation of novel and commercial TMJ implants.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Ramos%2C+A%2E%22">Ramos, A.</searchLink><relatesTo>1</relatesTo><i> a.ramos@ua.pt</i><br /><searchLink fieldCode="AR" term="%22Mesnard%2C+M%2E%22">Mesnard, M.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Relvas%2C+C%2E%22">Relvas, C.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Completo%2C+A%2E%22">Completo, A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Simôes%2C+J%2E+A%2E%22">Simôes, J. A.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Computer+Methods+in+Biomechanics+%26+Biomedical+Engineering%22">Computer Methods in Biomechanics & Biomedical Engineering</searchLink>. Sep2012 Supplement, Vol. 15, p324-325. 2p. 1 Diagram, 1 Chart, 1 Graph.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Artificial+implants%22">Artificial implants</searchLink><br /><searchLink fieldCode="DE" term="%22Tissue+fixation+%28Histology%29%22">Tissue fixation (Histology)</searchLink><br /><searchLink fieldCode="DE" term="%22Temporomandibular+joint+injuries%22">Temporomandibular joint injuries</searchLink><br /><searchLink fieldCode="DE" term="%22Bone+screws%22">Bone screws</searchLink><br /><searchLink fieldCode="DE" term="%22Three-dimensional+imaging%22">Three-dimensional imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+imaging+systems%22">Medical imaging systems</searchLink><br /><searchLink fieldCode="DE" term="%22Finite+element+method%22">Finite element method</searchLink><br /><searchLink fieldCode="DE" term="%22CAD%2FCAM+systems%22">CAD/CAM systems</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The article presents a study which analyzes and compares two types of implant fixation of human temporomandibular joint (TMJ )using commercial screws and the hypothetic intramedullary fixation. The study uses a three-dimensional (3D) finite element (FE) model and a computer-aided design (CAD) model of the implanted mandible. Results show the key role of the screw positions in the bone strain distribution.
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=80441419
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1080/10255842.2012.713600
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 2
        StartPage: 324
    Subjects:
      – SubjectFull: Artificial implants
        Type: general
      – SubjectFull: Tissue fixation (Histology)
        Type: general
      – SubjectFull: Temporomandibular joint injuries
        Type: general
      – SubjectFull: Bone screws
        Type: general
      – SubjectFull: Three-dimensional imaging
        Type: general
      – SubjectFull: Medical imaging systems
        Type: general
      – SubjectFull: Finite element method
        Type: general
      – SubjectFull: CAD/CAM systems
        Type: general
    Titles:
      – TitleFull: Implant fixation of novel and commercial TMJ implants.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Ramos, A.
      – PersonEntity:
          Name:
            NameFull: Mesnard, M.
      – PersonEntity:
          Name:
            NameFull: Relvas, C.
      – PersonEntity:
          Name:
            NameFull: Completo, A.
      – PersonEntity:
          Name:
            NameFull: Simôes, J. A.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 02
              M: 09
              Text: Sep2012 Supplement
              Type: published
              Y: 2012
          Identifiers:
            – Type: issn-print
              Value: 10255842
          Numbering:
            – Type: volume
              Value: 15
          Titles:
            – TitleFull: Computer Methods in Biomechanics & Biomedical Engineering
              Type: main
ResultId 1