Self-adapting cyclic registration for motion-compensated cone-beam CT in image-guided radiation therapy.

Saved in:
Bibliographic Details
Title: Self-adapting cyclic registration for motion-compensated cone-beam CT in image-guided radiation therapy.
Authors: Brehm, Marcus1, Paysan, Pascal2, Oelhafen, Markus2, Kunz, Patrik2, Kachelrieß, Marc1
Source: Medical Physics. Dec2012, Vol. 39 Issue 12, p7603-7618. 16p.
Subjects: Self-adaptive software, Image registration, Cone beam computed tomography, Image-guided radiation therapy, Image reconstruction, Algorithms, Image quality analysis
Abstract: Purpose: In image-guided radiation therapy an additional kV imaging system next to the linear particle accelerator provides information for an accurate patient positioning. However, the acquisition time of the system is much longer than the patient's breathing cycle due to the low gantry rotation speed. Our purpose is a cyclic registration in the context of motion-compensated image reconstruction that provides high quality respiratory-correlated 4D volumes for on-board flat panel detector cone-beam CT scans. Methods: Based on the small motion assumption, widely used within registration algorithms, a strategy is developed for motion estimation. In this strategy temporal restrictions are incorporated, for example, the cyclic motion patterns of respiration. The resultant cyclic registration method is to show less sensitivity on image artifacts, in particular on artifacts due to projection data sparsification. Using a new cyclic registration method a motion estimation is performed on respiratory-correlated reconstructions, and the obtained motion vector fields are used for motion compensation. Results: The proposed cyclic registration is evaluated in the context of motion-compensated image reconstruction using simulated data and patient data. Motion artifacts of 3D standard reconstructions can be significantly reduced by the resulting cyclic motion compensation. The method outperforms the respiratory-correlated reconstructions regarding sparse-view artifacts and maintains the high temporal resolution at the same time. Image artifacts show only minor to almost no effect on the motion estimation using the cyclic registration. Conclusions: The cyclic motion compensation approach provides respiratory-correlated volumes with high image quality. The cyclic motion estimation is of such low sensitivity to sparse-view artifacts, that it is capable to determine high quality motion vector fields based on reconstructions of low sampled data. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 83860293
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Self-adapting cyclic registration for motion-compensated cone-beam CT in image-guided radiation therapy.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Brehm%2C+Marcus%22">Brehm, Marcus</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Paysan%2C+Pascal%22">Paysan, Pascal</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Oelhafen%2C+Markus%22">Oelhafen, Markus</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Kunz%2C+Patrik%22">Kunz, Patrik</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Kachelrieß%2C+Marc%22">Kachelrieß, Marc</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Dec2012, Vol. 39 Issue 12, p7603-7618. 16p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Self-adaptive+software%22">Self-adaptive software</searchLink><br /><searchLink fieldCode="DE" term="%22Image+registration%22">Image registration</searchLink><br /><searchLink fieldCode="DE" term="%22Cone+beam+computed+tomography%22">Cone beam computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Image-guided+radiation+therapy%22">Image-guided radiation therapy</searchLink><br /><searchLink fieldCode="DE" term="%22Image+reconstruction%22">Image reconstruction</searchLink><br /><searchLink fieldCode="DE" term="%22Algorithms%22">Algorithms</searchLink><br /><searchLink fieldCode="DE" term="%22Image+quality+analysis%22">Image quality analysis</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: In image-guided radiation therapy an additional kV imaging system next to the linear particle accelerator provides information for an accurate patient positioning. However, the acquisition time of the system is much longer than the patient's breathing cycle due to the low gantry rotation speed. Our purpose is a cyclic registration in the context of motion-compensated image reconstruction that provides high quality respiratory-correlated 4D volumes for on-board flat panel detector cone-beam CT scans. Methods: Based on the small motion assumption, widely used within registration algorithms, a strategy is developed for motion estimation. In this strategy temporal restrictions are incorporated, for example, the cyclic motion patterns of respiration. The resultant cyclic registration method is to show less sensitivity on image artifacts, in particular on artifacts due to projection data sparsification. Using a new cyclic registration method a motion estimation is performed on respiratory-correlated reconstructions, and the obtained motion vector fields are used for motion compensation. Results: The proposed cyclic registration is evaluated in the context of motion-compensated image reconstruction using simulated data and patient data. Motion artifacts of 3D standard reconstructions can be significantly reduced by the resulting cyclic motion compensation. The method outperforms the respiratory-correlated reconstructions regarding sparse-view artifacts and maintains the high temporal resolution at the same time. Image artifacts show only minor to almost no effect on the motion estimation using the cyclic registration. Conclusions: The cyclic motion compensation approach provides respiratory-correlated volumes with high image quality. The cyclic motion estimation is of such low sensitivity to sparse-view artifacts, that it is capable to determine high quality motion vector fields based on reconstructions of low sampled data. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=83860293
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1118/1.4766435
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 16
        StartPage: 7603
    Subjects:
      – SubjectFull: Self-adaptive software
        Type: general
      – SubjectFull: Image registration
        Type: general
      – SubjectFull: Cone beam computed tomography
        Type: general
      – SubjectFull: Image-guided radiation therapy
        Type: general
      – SubjectFull: Image reconstruction
        Type: general
      – SubjectFull: Algorithms
        Type: general
      – SubjectFull: Image quality analysis
        Type: general
    Titles:
      – TitleFull: Self-adapting cyclic registration for motion-compensated cone-beam CT in image-guided radiation therapy.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Brehm, Marcus
      – PersonEntity:
          Name:
            NameFull: Paysan, Pascal
      – PersonEntity:
          Name:
            NameFull: Oelhafen, Markus
      – PersonEntity:
          Name:
            NameFull: Kunz, Patrik
      – PersonEntity:
          Name:
            NameFull: Kachelrieß, Marc
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 12
              Text: Dec2012
              Type: published
              Y: 2012
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 39
            – Type: issue
              Value: 12
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1