Four-Dimensional Speckle Tracking for Assessing Improvement in Left Ventricular Contractility After Coronary Angioplasty
Saved in:
| Title: | Four-Dimensional Speckle Tracking for Assessing Improvement in Left Ventricular Contractility After Coronary Angioplasty |
|---|---|
| Authors: | Arbeille, Philippe1 arbeille@med.univ-tours.fr, Angoulvant, Denis2, Zuj, Kathreen3, Patier, Jeanne2, Desveaux, Bernard2, Quilliet, Laurent2, Charbonnier, Bernard2 |
| Source: | Ultrasound in Medicine & Biology. Jan2013, Vol. 39 Issue 1, p102-110. 9p. |
| Subjects: | Cardiac contraction, Coronary disease, Angioplasty, Four-dimensional imaging, Echocardiography, Left heart ventricle |
| Abstract: | Abstract: The objective of the study was to identify and quantify the potential improvement of left ventricular contractility after percutaneous transluminal coronary angioplasty (PTCA) using 4-dimensional (4D) speckle tracking echocardiography (4D STE). We investigated 41 patients with coronary disease by 4D STE pre- and 24 hours postcoronarography with (n = 18) or without (n = 23) PTCA. The 4D STE visualizes in real time the myocardium strain on 2- and 4-chamber apical views and on 3 transverse views of the left ventricle. Average and total strain of the left ventricle were measured. Of the 18 PTCA patients, 15 showed significant increase in left ventricle mean (+15 ± 6) and total strain (240 ± 100), which corresponded to an increase of 93% ± 55% from precoronarography, whereas the remainder showed no change. The total strain corresponded to 33% ± 10% (before PTCA) and 59% ± 11% (post PTCA) of the estimated normal strain for each patient. Strain improved in 70% of the segment downstream from the stent, and there was a negative correlation between the amplitude of the mean and total strain improvements after 24 hours and the mean and total strain values before PTCA. In the non-PTCA group, 21 of the 23 patients showed no changes in strain, whereas 2 showed improvement. The 4D STE showed significant improvements in left ventricular contractility in more than 70% of the areas downstream from the PTCA segment. This corresponded to an increase in the initial contractility by approximately 93% ± 55%; however, the myocardium contractility remained approximately 59% of normal level. No changes were seen in patients without PTCA. [Copyright &y& Elsevier] |
| Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 83872845 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Four-Dimensional Speckle Tracking for Assessing Improvement in Left Ventricular Contractility After Coronary Angioplasty – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Arbeille%2C+Philippe%22">Arbeille, Philippe</searchLink><relatesTo>1</relatesTo><i> arbeille@med.univ-tours.fr</i><br /><searchLink fieldCode="AR" term="%22Angoulvant%2C+Denis%22">Angoulvant, Denis</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Zuj%2C+Kathreen%22">Zuj, Kathreen</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Patier%2C+Jeanne%22">Patier, Jeanne</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Desveaux%2C+Bernard%22">Desveaux, Bernard</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Quilliet%2C+Laurent%22">Quilliet, Laurent</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Charbonnier%2C+Bernard%22">Charbonnier, Bernard</searchLink><relatesTo>2</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Ultrasound+in+Medicine+%26+Biology%22">Ultrasound in Medicine & Biology</searchLink>. Jan2013, Vol. 39 Issue 1, p102-110. 9p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Cardiac+contraction%22">Cardiac contraction</searchLink><br /><searchLink fieldCode="DE" term="%22Coronary+disease%22">Coronary disease</searchLink><br /><searchLink fieldCode="DE" term="%22Angioplasty%22">Angioplasty</searchLink><br /><searchLink fieldCode="DE" term="%22Four-dimensional+imaging%22">Four-dimensional imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Echocardiography%22">Echocardiography</searchLink><br /><searchLink fieldCode="DE" term="%22Left+heart+ventricle%22">Left heart ventricle</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Abstract: The objective of the study was to identify and quantify the potential improvement of left ventricular contractility after percutaneous transluminal coronary angioplasty (PTCA) using 4-dimensional (4D) speckle tracking echocardiography (4D STE). We investigated 41 patients with coronary disease by 4D STE pre- and 24 hours postcoronarography with (n = 18) or without (n = 23) PTCA. The 4D STE visualizes in real time the myocardium strain on 2- and 4-chamber apical views and on 3 transverse views of the left ventricle. Average and total strain of the left ventricle were measured. Of the 18 PTCA patients, 15 showed significant increase in left ventricle mean (+15 ± 6) and total strain (240 ± 100), which corresponded to an increase of 93% ± 55% from precoronarography, whereas the remainder showed no change. The total strain corresponded to 33% ± 10% (before PTCA) and 59% ± 11% (post PTCA) of the estimated normal strain for each patient. Strain improved in 70% of the segment downstream from the stent, and there was a negative correlation between the amplitude of the mean and total strain improvements after 24 hours and the mean and total strain values before PTCA. In the non-PTCA group, 21 of the 23 patients showed no changes in strain, whereas 2 showed improvement. The 4D STE showed significant improvements in left ventricular contractility in more than 70% of the areas downstream from the PTCA segment. This corresponded to an increase in the initial contractility by approximately 93% ± 55%; however, the myocardium contractility remained approximately 59% of normal level. No changes were seen in patients without PTCA. [Copyright &y& Elsevier] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=83872845 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.ultrasmedbio.2012.08.021 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 9 StartPage: 102 Subjects: – SubjectFull: Cardiac contraction Type: general – SubjectFull: Coronary disease Type: general – SubjectFull: Angioplasty Type: general – SubjectFull: Four-dimensional imaging Type: general – SubjectFull: Echocardiography Type: general – SubjectFull: Left heart ventricle Type: general Titles: – TitleFull: Four-Dimensional Speckle Tracking for Assessing Improvement in Left Ventricular Contractility After Coronary Angioplasty Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Arbeille, Philippe – PersonEntity: Name: NameFull: Angoulvant, Denis – PersonEntity: Name: NameFull: Zuj, Kathreen – PersonEntity: Name: NameFull: Patier, Jeanne – PersonEntity: Name: NameFull: Desveaux, Bernard – PersonEntity: Name: NameFull: Quilliet, Laurent – PersonEntity: Name: NameFull: Charbonnier, Bernard IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Text: Jan2013 Type: published Y: 2013 Identifiers: – Type: issn-print Value: 03015629 Numbering: – Type: volume Value: 39 – Type: issue Value: 1 Titles: – TitleFull: Ultrasound in Medicine & Biology Type: main |
| ResultId | 1 |