Two-dimensional position-sensitive detectors for high resolution diffraction with neutrons and high energy synchrotron radiation
Saved in:
| Title: | Two-dimensional position-sensitive detectors for high resolution diffraction with neutrons and high energy synchrotron radiation |
|---|---|
| Authors: | Marmotti, M.1, Burmester, J.1, Haese-Seiller, M.1, Kampmann, R. reinhard.kampmann@gkss.de |
| Source: | Nuclear Instruments & Methods in Physics Research Section A. Jan2002, Vol. 477 Issue 1-3, p347. 6p. |
| Subjects: | Neutron counters, Synchrotron radiation |
| Abstract: | A two dimensional position-sensitive neutron detector has been developed at the Geesthacht Neutron Facility (GeNF) for the new diffractometer ARES which is dedicated to the analysis of residual stresses. The detector is a 3He and CF4 filled multiwire proportional counter with delay line readout and has a sensitive area of 300 mm×300 mm.The detector was tested at different 3He and CF4 partial pressures with a well collimated neutron beam. Excellent linearity and homogeneity of the detection probability combined with a spatial resolution of about 2 mm×2 mm were found. [Copyright &y& Elsevier] |
| Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 8663346 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Two-dimensional position-sensitive detectors for high resolution diffraction with neutrons and high energy synchrotron radiation – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Marmotti%2C+M%2E%22">Marmotti, M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Burmester%2C+J%2E%22">Burmester, J.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Haese-Seiller%2C+M%2E%22">Haese-Seiller, M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Kampmann%2C+R%2E%22">Kampmann, R.</searchLink><i> reinhard.kampmann@gkss.de</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Nuclear+Instruments+%26+Methods+in+Physics+Research+Section+A%22">Nuclear Instruments & Methods in Physics Research Section A</searchLink>. Jan2002, Vol. 477 Issue 1-3, p347. 6p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Neutron+counters%22">Neutron counters</searchLink><br /><searchLink fieldCode="DE" term="%22Synchrotron+radiation%22">Synchrotron radiation</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: A two dimensional position-sensitive neutron detector has been developed at the Geesthacht Neutron Facility (GeNF) for the new diffractometer ARES which is dedicated to the analysis of residual stresses. The detector is a 3He and CF4 filled multiwire proportional counter with delay line readout and has a sensitive area of 300 mm×300 mm.The detector was tested at different 3He and CF4 partial pressures with a well collimated neutron beam. Excellent linearity and homogeneity of the detection probability combined with a spatial resolution of about 2 mm×2 mm were found. [Copyright &y& Elsevier] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=8663346 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/S0168-9002(01)01864-2 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 6 StartPage: 347 Subjects: – SubjectFull: Neutron counters Type: general – SubjectFull: Synchrotron radiation Type: general Titles: – TitleFull: Two-dimensional position-sensitive detectors for high resolution diffraction with neutrons and high energy synchrotron radiation Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Marmotti, M. – PersonEntity: Name: NameFull: Burmester, J. – PersonEntity: Name: NameFull: Haese-Seiller, M. – PersonEntity: Name: NameFull: Kampmann, R. IsPartOfRelationships: – BibEntity: Dates: – D: 21 M: 01 Text: Jan2002 Type: published Y: 2002 Identifiers: – Type: issn-print Value: 01689002 Numbering: – Type: volume Value: 477 – Type: issue Value: 1-3 Titles: – TitleFull: Nuclear Instruments & Methods in Physics Research Section A Type: main |
| ResultId | 1 |