Evaluation of Suitable Material Properties of Sludge for Electroosmotic Dewatering.
Saved in:
| Title: | Evaluation of Suitable Material Properties of Sludge for Electroosmotic Dewatering. |
|---|---|
| Authors: | Yoshida, Hiroshi1 (AUTHOR) yoshida@oyama-ct.ac.jp, Yoshikawa, Tomomi1 (AUTHOR), Kawasaki, Midori1 (AUTHOR) |
| Source: | Drying Technology. May2013, Vol. 31 Issue 7, p775-784. 10p. 1 Diagram, 2 Charts, 8 Graphs. |
| Subjects: | Characterization of sewage sludge, Electroosmotic dewatering, Machine separators, Porous materials, High pressure (Science) |
| Abstract: | To estimate suitable material properties of sludge for electroosmotic dewatering, we experimentally measured the electrical and physical properties of a sludge bed. The use of an upper electrode that had a smaller area than the cross-sectional area of the bed was also investigated with the aim of reducing the electrical contact resistance between the electrode and the bed caused by dewatering. We found that sludge with a lower specific electrical resistance and a higher hydrodynamic compressibility in cake filtration provided greater electroosmotic dewatering performance. However, such a sludge was not necessarily available for using a smaller-area upper electrode. [ABSTRACT FROM PUBLISHER] |
| Copyright of Drying Technology is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | To estimate suitable material properties of sludge for electroosmotic dewatering, we experimentally measured the electrical and physical properties of a sludge bed. The use of an upper electrode that had a smaller area than the cross-sectional area of the bed was also investigated with the aim of reducing the electrical contact resistance between the electrode and the bed caused by dewatering. We found that sludge with a lower specific electrical resistance and a higher hydrodynamic compressibility in cake filtration provided greater electroosmotic dewatering performance. However, such a sludge was not necessarily available for using a smaller-area upper electrode. [ABSTRACT FROM PUBLISHER] |
|---|---|
| ISSN: | 07373937 |
| DOI: | 10.1080/07373937.2012.760581 |