Evaluation of MRI artifacts at 3 Tesla for 38 commonly used cosmetics
Saved in:
| Title: | Evaluation of MRI artifacts at 3 Tesla for 38 commonly used cosmetics |
|---|---|
| Authors: | Escher, Kirin1, Shellock, Frank G.2 frank.shellock@mrisafety.com |
| Source: | Magnetic Resonance Imaging (0730725X). Jun2013, Vol. 31 Issue 5, p778-782. 5p. |
| Subjects: | Magnetic resonance imaging, Cosmetics, Imaging phantoms, Contrast media, Baldness, Eye care |
| Abstract: | Abstract: Purpose: To evaluate MRI artifacts at 3-Tesla for 38 commonly used cosmetics. Materials and Methods: Thirty-eight cosmetics (16, nail polishes; 5, eyeliners; 3, mascaras; 10, eye shadows; 1, lip gloss; 1, body lotion; 1, body glitter, and 1, hair loss concealer) underwent evaluation for MRI artifacts at 3-Tesla. The cosmetics were applied a copper-sulfate-filled, phantom and initially assessed using a “screening” gradient echo (GRE) pulse sequence. Of the 38 different cosmetics, 14 (37%) exhibited artifacts. For these 14 cosmetics, additional characterization of artifacts was performed using a GRE pulse sequence. A qualitative scale was applied to characterize the artifact size. Results: Artifacts were observed, as follows: 2, nail polishes; 5, eyeliners; 3, mascaras; 3, eye shadows; 1, hair loss concealer. Artifact size ranged from small (eye shadow) to very large (hair loss concealer) and tended to be associated with the presence of iron oxide or other metal-based ingredient. Conclusions: Commonly used cosmetics caused artifacts that may create issues if the area of interest is the same as where the cosmetic was applied or if its presence was unknown, thus, potentially causing it to be construed as pathology. Therefore, these findings have important implications for patients referred for MRI examinations. [Copyright &y& Elsevier] |
| Copyright of Magnetic Resonance Imaging (0730725X) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 87503500 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Evaluation of MRI artifacts at 3 Tesla for 38 commonly used cosmetics – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Escher%2C+Kirin%22">Escher, Kirin</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Shellock%2C+Frank+G%2E%22">Shellock, Frank G.</searchLink><relatesTo>2</relatesTo><i> frank.shellock@mrisafety.com</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Magnetic+Resonance+Imaging+%280730725X%29%22">Magnetic Resonance Imaging (0730725X)</searchLink>. Jun2013, Vol. 31 Issue 5, p778-782. 5p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Magnetic+resonance+imaging%22">Magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Cosmetics%22">Cosmetics</searchLink><br /><searchLink fieldCode="DE" term="%22Imaging+phantoms%22">Imaging phantoms</searchLink><br /><searchLink fieldCode="DE" term="%22Contrast+media%22">Contrast media</searchLink><br /><searchLink fieldCode="DE" term="%22Baldness%22">Baldness</searchLink><br /><searchLink fieldCode="DE" term="%22Eye+care%22">Eye care</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Abstract: Purpose: To evaluate MRI artifacts at 3-Tesla for 38 commonly used cosmetics. Materials and Methods: Thirty-eight cosmetics (16, nail polishes; 5, eyeliners; 3, mascaras; 10, eye shadows; 1, lip gloss; 1, body lotion; 1, body glitter, and 1, hair loss concealer) underwent evaluation for MRI artifacts at 3-Tesla. The cosmetics were applied a copper-sulfate-filled, phantom and initially assessed using a “screening” gradient echo (GRE) pulse sequence. Of the 38 different cosmetics, 14 (37%) exhibited artifacts. For these 14 cosmetics, additional characterization of artifacts was performed using a GRE pulse sequence. A qualitative scale was applied to characterize the artifact size. Results: Artifacts were observed, as follows: 2, nail polishes; 5, eyeliners; 3, mascaras; 3, eye shadows; 1, hair loss concealer. Artifact size ranged from small (eye shadow) to very large (hair loss concealer) and tended to be associated with the presence of iron oxide or other metal-based ingredient. Conclusions: Commonly used cosmetics caused artifacts that may create issues if the area of interest is the same as where the cosmetic was applied or if its presence was unknown, thus, potentially causing it to be construed as pathology. Therefore, these findings have important implications for patients referred for MRI examinations. [Copyright &y& Elsevier] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Magnetic Resonance Imaging (0730725X) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=87503500 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.mri.2012.11.002 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 5 StartPage: 778 Subjects: – SubjectFull: Magnetic resonance imaging Type: general – SubjectFull: Cosmetics Type: general – SubjectFull: Imaging phantoms Type: general – SubjectFull: Contrast media Type: general – SubjectFull: Baldness Type: general – SubjectFull: Eye care Type: general Titles: – TitleFull: Evaluation of MRI artifacts at 3 Tesla for 38 commonly used cosmetics Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Escher, Kirin – PersonEntity: Name: NameFull: Shellock, Frank G. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 06 Text: Jun2013 Type: published Y: 2013 Identifiers: – Type: issn-print Value: 0730725X Numbering: – Type: volume Value: 31 – Type: issue Value: 5 Titles: – TitleFull: Magnetic Resonance Imaging (0730725X) Type: main |
| ResultId | 1 |