Evaluation of MRI issues for a new neurological implant, the Sensor Reservoir.

Saved in:
Bibliographic Details
Title: Evaluation of MRI issues for a new neurological implant, the Sensor Reservoir.
Authors: Shellock, Frank G.1 frank.shellock@mrisafety.com, Knebel, Jörg2 joerg.knebel@miethke.com, Prat, Angelina D.3 angelina_prat@yahoo.com
Source: Magnetic Resonance Imaging (0730725X). Sep2013, Vol. 31 Issue 7, p1245-1250. 6p.
Subjects: Magnetic resonance imaging, Neurosurgery, Noninvasive diagnostic tests, Surgical drainage, Contrast media, Cerebrospinal fluid
Abstract: Abstract: Background and Purpose: A new neurological implant, the Sensor-Reservoir, was developed to provide a relative measurement of ICP, which permits a noninvasive technique to detect and localize occlusions in ventricular drainage systems and, thus, to identify mechanical damage to shunt valves. The “reservoir” of this device can be used to administer medication or a contrast agent, to extract cerebral spinal fluid (CSF), and with the possibility of directly measuring ICP. The Sensor-Reservoir was evaluated to identify possible MRI-related issues at 1.5-T/64-MHz and 3-T/128-MHz. Materials and Methods: Standard testing techniques were utilized to evaluate magnetic field interactions (i.e., translational attraction and torque), MRI-related heating, and artifacts at 3-T for the Sensor-Reservoir. In addition, 12 samples of the Sensor-Reservoir underwent testing to determine if the function of these devices was affected by exposures to various MRI conditions at 1.5-T/64-MHz and 3-T/128-MHz. Results: Magnetic field interactions for the Sensor-Reservoir were not substantial. The heating results indicated a highest temperature rise of 1.8°C, which poses no patient risks. Artifacts were relatively small in relation to the size and shape of the Sensor-Reservoir, but may interfere diagnostically if the area of interest is near the device. All devices were unaffected by exposures to MRI conditions at 1.5-T/64-MHz and 3-T/128-MHz. Conclusion: When specific guidelines are followed, the Sensor-Reservoir is “MR conditional” for patients undergoing MRI examinations at 3-T or less. [Copyright &y& Elsevier]
Copyright of Magnetic Resonance Imaging (0730725X) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Be the first to leave a comment!
You must be logged in first