Optimal table feed in run-off CT angiography in patients with abdominal aortic aneurysms.
Saved in:
| Title: | Optimal table feed in run-off CT angiography in patients with abdominal aortic aneurysms. |
|---|---|
| Authors: | Werncke, T.1 Thomas.Werncke@charite.de, Falck, C.2 Falck.Christian.von@mh-hannover.de, Wittmann, M.3, Elgeti, T.4, Wacker, F.2, Meyer, B.2 |
| Source: | European Radiology. Sep2013, Vol. 23 Issue 9, p2482-2491. 10p. 1 Diagram, 4 Charts, 2 Graphs. |
| Subjects: | Aortic aneurysm diagnosis, Angiography, Aortic aneurysms, Multidetector computed tomography, Retrospective studies, Radioscopic diagnosis, Patients |
| Abstract: | Objectives: To assess the influence of different table feeds (TFs) on vascular enhancement and image quality in patients with an abdominal aortic aneurysm (AAA) undergoing computed tomography (CT) angiography of the lower extremities (run-off CTA). Methods: Seventy-nine patients (71 ± 8 years) with an AAA (>30 mm) who underwent run-off CTA between January 2004 and August 2011 were included in this retrospective institutional review board-approved study. Run-off CTA was conducted using 16- and 64-row CT. The range of TFs was 30-86 mm/s and was categorised in quartiles TF1 (32.6 ± 1.9 mm/s), TF2 (38.9 ± 0.9 mm/s), TF3 (43.9 ± 3.1 mm/s) and TF4 (57.4 ± 10.5 mm/s). Image quality was rated independently by two radiologists and vessel enhancement was assessed. Results: Image quality was diagnostic at all aortic, pelvic and almost all thigh levels. Below the knee, the number of diagnostic levels was highest for TF1 and decreased to TF4. Arterial enhancement between the aorta and fibular trunk was not different in all TF groups, P > 0.05. At the calf and foot strongest arterial enhancement was noted for TF1 and TF2 and decreased to TF4, P < 0.01. Conclusion: Results indicate that the highest image quality of run-off CTA in patients with an AAA may be obtained using table feeds measuring 30-35 mm/s. Key Points: • CTA has become a key investigation for peripheral vascular disease. • Run-off CTA is more complex in patients with an abdominal aortic aneurysm. • Run-off CTA is feasible with a short bolus of intravenous contrast medium. • A constant 30-35 mm/s table feed provides the highest likelihood of diagnostic images. [ABSTRACT FROM AUTHOR] |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 89622697 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Optimal table feed in run-off CT angiography in patients with abdominal aortic aneurysms. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Werncke%2C+T%2E%22">Werncke, T.</searchLink><relatesTo>1</relatesTo><i> Thomas.Werncke@charite.de</i><br /><searchLink fieldCode="AR" term="%22Falck%2C+C%2E%22">Falck, C.</searchLink><relatesTo>2</relatesTo><i> Falck.Christian.von@mh-hannover.de</i><br /><searchLink fieldCode="AR" term="%22Wittmann%2C+M%2E%22">Wittmann, M.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Elgeti%2C+T%2E%22">Elgeti, T.</searchLink><relatesTo>4</relatesTo><br /><searchLink fieldCode="AR" term="%22Wacker%2C+F%2E%22">Wacker, F.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Meyer%2C+B%2E%22">Meyer, B.</searchLink><relatesTo>2</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Sep2013, Vol. 23 Issue 9, p2482-2491. 10p. 1 Diagram, 4 Charts, 2 Graphs. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Aortic+aneurysm+diagnosis%22">Aortic aneurysm diagnosis</searchLink><br /><searchLink fieldCode="DE" term="%22Angiography%22">Angiography</searchLink><br /><searchLink fieldCode="DE" term="%22Aortic+aneurysms%22">Aortic aneurysms</searchLink><br /><searchLink fieldCode="DE" term="%22Multidetector+computed+tomography%22">Multidetector computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Retrospective+studies%22">Retrospective studies</searchLink><br /><searchLink fieldCode="DE" term="%22Radioscopic+diagnosis%22">Radioscopic diagnosis</searchLink><br /><searchLink fieldCode="DE" term="%22Patients%22">Patients</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Objectives: To assess the influence of different table feeds (TFs) on vascular enhancement and image quality in patients with an abdominal aortic aneurysm (AAA) undergoing computed tomography (CT) angiography of the lower extremities (run-off CTA). Methods: Seventy-nine patients (71 ± 8 years) with an AAA (>30 mm) who underwent run-off CTA between January 2004 and August 2011 were included in this retrospective institutional review board-approved study. Run-off CTA was conducted using 16- and 64-row CT. The range of TFs was 30-86 mm/s and was categorised in quartiles TF1 (32.6 ± 1.9 mm/s), TF2 (38.9 ± 0.9 mm/s), TF3 (43.9 ± 3.1 mm/s) and TF4 (57.4 ± 10.5 mm/s). Image quality was rated independently by two radiologists and vessel enhancement was assessed. Results: Image quality was diagnostic at all aortic, pelvic and almost all thigh levels. Below the knee, the number of diagnostic levels was highest for TF1 and decreased to TF4. Arterial enhancement between the aorta and fibular trunk was not different in all TF groups, P > 0.05. At the calf and foot strongest arterial enhancement was noted for TF1 and TF2 and decreased to TF4, P < 0.01. Conclusion: Results indicate that the highest image quality of run-off CTA in patients with an AAA may be obtained using table feeds measuring 30-35 mm/s. Key Points: • CTA has become a key investigation for peripheral vascular disease. • Run-off CTA is more complex in patients with an abdominal aortic aneurysm. • Run-off CTA is feasible with a short bolus of intravenous contrast medium. • A constant 30-35 mm/s table feed provides the highest likelihood of diagnostic images. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=89622697 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s00330-013-2865-3 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 2482 Subjects: – SubjectFull: Aortic aneurysm diagnosis Type: general – SubjectFull: Angiography Type: general – SubjectFull: Aortic aneurysms Type: general – SubjectFull: Multidetector computed tomography Type: general – SubjectFull: Retrospective studies Type: general – SubjectFull: Radioscopic diagnosis Type: general – SubjectFull: Patients Type: general Titles: – TitleFull: Optimal table feed in run-off CT angiography in patients with abdominal aortic aneurysms. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Werncke, T. – PersonEntity: Name: NameFull: Falck, C. – PersonEntity: Name: NameFull: Wittmann, M. – PersonEntity: Name: NameFull: Elgeti, T. – PersonEntity: Name: NameFull: Wacker, F. – PersonEntity: Name: NameFull: Meyer, B. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 09 Text: Sep2013 Type: published Y: 2013 Identifiers: – Type: issn-print Value: 09387994 Numbering: – Type: volume Value: 23 – Type: issue Value: 9 Titles: – TitleFull: European Radiology Type: main |
| ResultId | 1 |