Effect of 176Lu intrinsic radioactivity on dual head PET system imaging and data acquisition, simulation, and experimental measurements.

Saved in:
Bibliographic Details
Title: Effect of 176Lu intrinsic radioactivity on dual head PET system imaging and data acquisition, simulation, and experimental measurements.
Authors: Efthimiou, Nikos1, Loudos, George2, Karakatsanis, Nicolas A.3, Panayiotakis, George S.1
Source: Medical Physics. Nov2013, Vol. 40 Issue 11, p112505-N.PAG. 10p.
Subjects: Radioactivity, Lutetium, Data acquisition systems, Positron emission tomography, Photon scattering, Image quality in radiography
Abstract: Purpose: In this work, the authors aim for the estimation of the effect of 176Lu intrinsic radioactivity on the performance of a dual head PET system dedicated to small animal imaging. Methods: A prototype camera has been used as a reference system in order to validate two GATE simulation models, which were used for the investigation. The first model includes the 176Lu intrinsic radioactivity, while the second does not. The two models have been designed in order to provide similar sensitivities, in terms of count rate performance and scatter fraction, in the linear range of activities. In addition, the model with the 176Lu intrinsic radioactivity, has been validated in terms of background count rate. Different acquisition schemes have been examined in order to determine the optimum conditions to minimize the 176Lu effects, while maintaining a high trues count rate. In addition, the effect on the image quality, in terms of spatial resolution, signal-to-noise ratio, and minimum detectable activity, was investigated. Results: Both models are in good agreement with the measured data. While, the presence of the 176Lu altered the dead time of the model, it also affected the singles, trues, and randoms count rates. The noise equivalent count rate curves of the two models indicate that for low activities, the lack of 176Lu radioactivity leads to better noise properties due to the underestimation of the randoms. Signal-to-noise ratio measurement on coincidence images confirm the aforementioned claim, since the model without the 176Lu provides better less noisy images. Furthermore, the spatial resolution and the minimum detectable activity are overestimated. Conclusions: It has been proven that the lack of the 176Lu intrinsic radioactivity has an impact on the design of the simulation model's dead time. Even if there is an alignment with experimental results still the noise properties, for a wide range of activities, are overestimated. In addition, for low activities, better image quality, is presented, mainly due to the lack of the 176Lu photons which blur the images. Furthermore, it was shown that the use of a high hardware threshold allows the application of a wide energy window, which improves the statistics without a significant compromise on the quality of the detected photons, mainly, due to the early rejection of the low energy photons and the low scatter factor. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 92707025
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Effect of 176Lu intrinsic radioactivity on dual head PET system imaging and data acquisition, simulation, and experimental measurements.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Efthimiou%2C+Nikos%22">Efthimiou, Nikos</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Loudos%2C+George%22">Loudos, George</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Karakatsanis%2C+Nicolas+A%2E%22">Karakatsanis, Nicolas A.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Panayiotakis%2C+George+S%2E%22">Panayiotakis, George S.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Nov2013, Vol. 40 Issue 11, p112505-N.PAG. 10p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Radioactivity%22">Radioactivity</searchLink><br /><searchLink fieldCode="DE" term="%22Lutetium%22">Lutetium</searchLink><br /><searchLink fieldCode="DE" term="%22Data+acquisition+systems%22">Data acquisition systems</searchLink><br /><searchLink fieldCode="DE" term="%22Positron+emission+tomography%22">Positron emission tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Photon+scattering%22">Photon scattering</searchLink><br /><searchLink fieldCode="DE" term="%22Image+quality+in+radiography%22">Image quality in radiography</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: In this work, the authors aim for the estimation of the effect of 176Lu intrinsic radioactivity on the performance of a dual head PET system dedicated to small animal imaging. Methods: A prototype camera has been used as a reference system in order to validate two GATE simulation models, which were used for the investigation. The first model includes the 176Lu intrinsic radioactivity, while the second does not. The two models have been designed in order to provide similar sensitivities, in terms of count rate performance and scatter fraction, in the linear range of activities. In addition, the model with the 176Lu intrinsic radioactivity, has been validated in terms of background count rate. Different acquisition schemes have been examined in order to determine the optimum conditions to minimize the 176Lu effects, while maintaining a high trues count rate. In addition, the effect on the image quality, in terms of spatial resolution, signal-to-noise ratio, and minimum detectable activity, was investigated. Results: Both models are in good agreement with the measured data. While, the presence of the 176Lu altered the dead time of the model, it also affected the singles, trues, and randoms count rates. The noise equivalent count rate curves of the two models indicate that for low activities, the lack of 176Lu radioactivity leads to better noise properties due to the underestimation of the randoms. Signal-to-noise ratio measurement on coincidence images confirm the aforementioned claim, since the model without the 176Lu provides better less noisy images. Furthermore, the spatial resolution and the minimum detectable activity are overestimated. Conclusions: It has been proven that the lack of the 176Lu intrinsic radioactivity has an impact on the design of the simulation model's dead time. Even if there is an alignment with experimental results still the noise properties, for a wide range of activities, are overestimated. In addition, for low activities, better image quality, is presented, mainly due to the lack of the 176Lu photons which blur the images. Furthermore, it was shown that the use of a high hardware threshold allows the application of a wide energy window, which improves the statistics without a significant compromise on the quality of the detected photons, mainly, due to the early rejection of the low energy photons and the low scatter factor. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=92707025
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1118/1.4824694
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 112505
    Subjects:
      – SubjectFull: Radioactivity
        Type: general
      – SubjectFull: Lutetium
        Type: general
      – SubjectFull: Data acquisition systems
        Type: general
      – SubjectFull: Positron emission tomography
        Type: general
      – SubjectFull: Photon scattering
        Type: general
      – SubjectFull: Image quality in radiography
        Type: general
    Titles:
      – TitleFull: Effect of 176Lu intrinsic radioactivity on dual head PET system imaging and data acquisition, simulation, and experimental measurements.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Efthimiou, Nikos
      – PersonEntity:
          Name:
            NameFull: Loudos, George
      – PersonEntity:
          Name:
            NameFull: Karakatsanis, Nicolas A.
      – PersonEntity:
          Name:
            NameFull: Panayiotakis, George S.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2013
              Type: published
              Y: 2013
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 40
            – Type: issue
              Value: 11
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1