Broadband calibration of E-field probes in lossy media [mobile telephone safety application].

Saved in:
Bibliographic Details
Title: Broadband calibration of E-field probes in lossy media [mobile telephone safety application].
Authors: Meier, K.1, Burkhardt, M.1, Schmid, T.1, Kuster, N.1
Source: IEEE Transactions on Microwave Theory & Techniques. 1996, Vol. 44 Issue 10, p1954-1962. 9p.
Subjects: Liquid dielectrics, Electric field strength, Calibration, Physiological effects of radiation, Dielectric measurements, Cell phones, Uncertainty, Safety
Abstract: A broadband calibration procedure for E-field probes that minimizes the overall uncertainties inherent in E-field measurements in lossy dielectric liquids has been developed. The analysis of the calibration requirements shows that probes that are symmetrical with respect to their axis greatly facilitate accurate calibration, since the calibration procedure can be divided into several discrete steps. Such a procedure is presented and analyzed with respect to its uncertainties. Absolute calibration is performed at three frequency bands utilized in Europe for mobile communications (450 MHz, 900 MHz, and 1.8 GHz) and in different tissue-simulating liquids. The parameters obtained are verified by numerical simulations of the probe in the surrounding media. Such simulations allow the assessment of some of the calibration parameters with sufficient accuracy in cases where the experimental determination would be too tedious and time consuming. [ABSTRACT FROM AUTHOR]
Copyright of IEEE Transactions on Microwave Theory & Techniques is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:A broadband calibration procedure for E-field probes that minimizes the overall uncertainties inherent in E-field measurements in lossy dielectric liquids has been developed. The analysis of the calibration requirements shows that probes that are symmetrical with respect to their axis greatly facilitate accurate calibration, since the calibration procedure can be divided into several discrete steps. Such a procedure is presented and analyzed with respect to its uncertainties. Absolute calibration is performed at three frequency bands utilized in Europe for mobile communications (450 MHz, 900 MHz, and 1.8 GHz) and in different tissue-simulating liquids. The parameters obtained are verified by numerical simulations of the probe in the surrounding media. Such simulations allow the assessment of some of the calibration parameters with sufficient accuracy in cases where the experimental determination would be too tedious and time consuming. [ABSTRACT FROM AUTHOR]