Analysis of the intra-individual differences of the joint surfaces of the calcaneus.
Saved in:
| Title: | Analysis of the intra-individual differences of the joint surfaces of the calcaneus. |
|---|---|
| Authors: | Stephan, Daniel1,2, Panzer, Stephanie3, Göttlinger, Michael1, Augat, Peter1,2 |
| Source: | Computer Methods in Biomechanics & Biomedical Engineering. Nov2014, Vol. 17 Issue 15, p1635-1641. 7p. |
| Subjects: | Heel bone, Joints (Anatomy), Biomedical engineering, Computed tomography, T-test (Statistics) |
| Abstract: | Patients with calcaneus fractures experience considerable interferences with daily living activities. The quality of anatomical reconstruction is important because of its influence on functional outcome. The aim of this study was to develop an automatic algorithm based on computer tomographic (CT) images to quantify the integrity of calcaneal joint surfaces. Validation of this algorithm was done by assessing intra-individual variations of characteristic joint parameters. Bilateral hind foot CT data of 12 subjects were manually segmented, and 3D models from the calcaneus, talus and cuboid were generated. These models were implemented in a custom-made software to analyse the area, 3D orientations and bone distance of the joint surfaces of the calcaneus. Three joints were detected, and the calculated parameters were compared between right and left hind foot by the evaluation of the directional asymmetry (%DA). The results were statistically analysed with a pairedt-test. The median of area (5–7 %DA) of the joint surfaces and the distance between two articulating surfaces (8–9 %DA) showed the greatest intra-individual differences. Median differences in 3D orientation were comparatively low (1–2 %DA). None of these differences was statistically significant. Inter-individual variations among subjects were several magnitudes larger than intra-individual differences. The presented computational tool provides 3D joint-specific parameters of the calcaneus, which enable to describe their respective joint integrity. The results show that only small intra-individual differences within the anatomy exist. Surgical treatment should take place with the aid of CT data from the contralateral side. Thus, a good restoration of the anatomy may be reached. The computational tool assesses the quality of reduction, and may be helpful to evaluate the outcome and quality of operative treatment based on the calculated joint-specific parameters of joint reconstructions in the hind foot. [ABSTRACT FROM AUTHOR] |
| Copyright of Computer Methods in Biomechanics & Biomedical Engineering is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 96223201 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Analysis of the intra-individual differences of the joint surfaces of the calcaneus. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Stephan%2C+Daniel%22">Stephan, Daniel</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Panzer%2C+Stephanie%22">Panzer, Stephanie</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Göttlinger%2C+Michael%22">Göttlinger, Michael</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Augat%2C+Peter%22">Augat, Peter</searchLink><relatesTo>1,2</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Computer+Methods+in+Biomechanics+%26+Biomedical+Engineering%22">Computer Methods in Biomechanics & Biomedical Engineering</searchLink>. Nov2014, Vol. 17 Issue 15, p1635-1641. 7p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Heel+bone%22">Heel bone</searchLink><br /><searchLink fieldCode="DE" term="%22Joints+%28Anatomy%29%22">Joints (Anatomy)</searchLink><br /><searchLink fieldCode="DE" term="%22Biomedical+engineering%22">Biomedical engineering</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22T-test+%28Statistics%29%22">T-test (Statistics)</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Patients with calcaneus fractures experience considerable interferences with daily living activities. The quality of anatomical reconstruction is important because of its influence on functional outcome. The aim of this study was to develop an automatic algorithm based on computer tomographic (CT) images to quantify the integrity of calcaneal joint surfaces. Validation of this algorithm was done by assessing intra-individual variations of characteristic joint parameters. Bilateral hind foot CT data of 12 subjects were manually segmented, and 3D models from the calcaneus, talus and cuboid were generated. These models were implemented in a custom-made software to analyse the area, 3D orientations and bone distance of the joint surfaces of the calcaneus. Three joints were detected, and the calculated parameters were compared between right and left hind foot by the evaluation of the directional asymmetry (%DA). The results were statistically analysed with a pairedt-test. The median of area (5–7 %DA) of the joint surfaces and the distance between two articulating surfaces (8–9 %DA) showed the greatest intra-individual differences. Median differences in 3D orientation were comparatively low (1–2 %DA). None of these differences was statistically significant. Inter-individual variations among subjects were several magnitudes larger than intra-individual differences. The presented computational tool provides 3D joint-specific parameters of the calcaneus, which enable to describe their respective joint integrity. The results show that only small intra-individual differences within the anatomy exist. Surgical treatment should take place with the aid of CT data from the contralateral side. Thus, a good restoration of the anatomy may be reached. The computational tool assesses the quality of reduction, and may be helpful to evaluate the outcome and quality of operative treatment based on the calculated joint-specific parameters of joint reconstructions in the hind foot. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Computer Methods in Biomechanics & Biomedical Engineering is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=96223201 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1080/10255842.2012.759564 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 7 StartPage: 1635 Subjects: – SubjectFull: Heel bone Type: general – SubjectFull: Joints (Anatomy) Type: general – SubjectFull: Biomedical engineering Type: general – SubjectFull: Computed tomography Type: general – SubjectFull: T-test (Statistics) Type: general Titles: – TitleFull: Analysis of the intra-individual differences of the joint surfaces of the calcaneus. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Stephan, Daniel – PersonEntity: Name: NameFull: Panzer, Stephanie – PersonEntity: Name: NameFull: Göttlinger, Michael – PersonEntity: Name: NameFull: Augat, Peter IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 11 Text: Nov2014 Type: published Y: 2014 Identifiers: – Type: issn-print Value: 10255842 Numbering: – Type: volume Value: 17 – Type: issue Value: 15 Titles: – TitleFull: Computer Methods in Biomechanics & Biomedical Engineering Type: main |
| ResultId | 1 |