Bibliographic Details
| Title: |
Comparison of the Cardiopulmonary Response to Exercise in Recipients of Dual Sensor DDDR Pacemakers Versus a Healthy Control Group. |
| Authors: |
PAGE, ERIC, DEFAYE, PASCAL, BONNET, JEAN-LUC, DURAND, CATHERINE, AMBLARD, AMEL |
| Source: |
Pacing & Clinical Electrophysiology. Jan2003, Vol. 26 Issue 1, p239. 5p. |
| Subjects: |
Muscle strength, Exercise, Cardiac pacing, Heart beat |
| Abstract: |
PAGE, E.,et al.:Comparison of the Cardiopulmonary Response to Exercise in Recipients of Dual Sensor DDDR Pacemakers Versus a Healthy Control Group.The authors previously have shown in healthy subjects that age related loss of muscular strength did not alter the chronotropic response during treadmill exercise, whether with sudden onset of effort, as in the chronotropic assessment exercise protocol (CAEP) or more gradual effort as in the Harbor exercise protocol. This study was performed to verify that in patients suffering from chronotropic insufficiency, and in absence of other effort-limiting disorders, “physiologic” pacing enables a cardiorespiratory response comparable to that of age-matched healthy subjects. Furthermore, the aim of the study was to confirm that the response of a new dual sensor-based pacing system was properly adapted to the metabolic demand, whether during CAEP or during Harbor test, by subjecting patients to both protocols. All study participants were able to undergo treadmill exercise testing, had normal cardiopulmonary function tests at rest, and no cardiac, muscular, or pulmonary disease. A healthy group (control) included 16 subjects (mean age 70.4 ± 3.9 years), and the test group (pacemaker [PM]) included 9 subjects (mean age 67.1 ± 10.8 years) permanently paced for isolated chronotropic insufficiency with a dual sensor pacing system. All subjects underwent CAEP and Harbor tests with measurements of gas exchange, 24 hours apart, in randomized order. All subjects reached an appropriate level of exercise, as expressed by mean lactate plasma concentrations, which were slightly higher in the control than the PM group during CAEP (4.9 ± 1.9 vs 3.7 ± 1.9 mmol/L, NS) and Harbor (5.3 ± 1.9 vs 3.8 ± 1.8 mmol/L, P < 0.05) tests. No statistical difference was observed in VO[sub 2] and VE at peak exercise between the two groups during either test. In the PM group, heart rate at peak exercise and... [ABSTRACT FROM AUTHOR] |
|
Copyright of Pacing & Clinical Electrophysiology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
Engineering Source |