Evaluation of Self-Contained PACS Viewers on CD-ROM.

Saved in:
Bibliographic Details
Title: Evaluation of Self-Contained PACS Viewers on CD-ROM.
Authors: Hosch, Richard1 rehosch@umc.edu, Rivard, Andrew1 arivard@umc.edu
Source: Journal of Digital Imaging. Aug2014, Vol. 27 Issue 4, p470-473. 4p.
Subjects: CD-ROMs, Commercial product evaluation, Computer graphics, Patient education, Picture archiving & communication systems, Dicom (Computer network protocol)
Abstract: Providing patients and clinicians with self-contained PACS viewer on CD format is a common and necessary tool to share vital imaging data. However, to be useful, this tool should be reliable, robust, and convenient. Numerous PACS viewer options are available, often without empirical data to guide in choosing one for routine use. To assist in making a standardized choice for our institution, we chose four common viewers, benchmarked on four different workstations reflecting the variety of environments used by non-radiologist clinicians who would receive a CD. Four CD-based DICOM viewers from eFilm, Philips, Pacsgear Gearview, and iSite were examed on two radiology PACS workstations, a standard desktop computer, and a laptop using a test case consisting of a multi-series CTA with 13 series and 3,035 total images. Multiple objective measures, subjective measures, and presence of key features were evaluated including program time to load, image time to load, cine/movie mode, ability to adequately window and level, pan and zoom functionality, basic measurement tools, and perceived lag when scrolling through a multi-image series. Substantial differences in speed of operation and behavior on multiple systems were documented, which could potentially add several minutes to the time required to open and view a patient's imaging data. The eFilm and iSite viewers operated consistently and reliably across all tested computer environments. The iSite viewer, having among the quickest load times in the group tested and consistently low subjective scroll lag during series viewing, and also beneficially allowing partial viewing while images load in the background, was found to generate the best overall user experience. Because of these significant differences, we have recommended that our institution standardize all patient imaging CD creation using the iSite viewer. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Digital Imaging is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 96967535
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Evaluation of Self-Contained PACS Viewers on CD-ROM.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Hosch%2C+Richard%22">Hosch, Richard</searchLink><relatesTo>1</relatesTo><i> rehosch@umc.edu</i><br /><searchLink fieldCode="AR" term="%22Rivard%2C+Andrew%22">Rivard, Andrew</searchLink><relatesTo>1</relatesTo><i> arivard@umc.edu</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Journal+of+Digital+Imaging%22">Journal of Digital Imaging</searchLink>. Aug2014, Vol. 27 Issue 4, p470-473. 4p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22CD-ROMs%22">CD-ROMs</searchLink><br /><searchLink fieldCode="DE" term="%22Commercial+product+evaluation%22">Commercial product evaluation</searchLink><br /><searchLink fieldCode="DE" term="%22Computer+graphics%22">Computer graphics</searchLink><br /><searchLink fieldCode="DE" term="%22Patient+education%22">Patient education</searchLink><br /><searchLink fieldCode="DE" term="%22Picture+archiving+%26+communication+systems%22">Picture archiving & communication systems</searchLink><br /><searchLink fieldCode="DE" term="%22Dicom+%28Computer+network+protocol%29%22">Dicom (Computer network protocol)</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Providing patients and clinicians with self-contained PACS viewer on CD format is a common and necessary tool to share vital imaging data. However, to be useful, this tool should be reliable, robust, and convenient. Numerous PACS viewer options are available, often without empirical data to guide in choosing one for routine use. To assist in making a standardized choice for our institution, we chose four common viewers, benchmarked on four different workstations reflecting the variety of environments used by non-radiologist clinicians who would receive a CD. Four CD-based DICOM viewers from eFilm, Philips, Pacsgear Gearview, and iSite were examed on two radiology PACS workstations, a standard desktop computer, and a laptop using a test case consisting of a multi-series CTA with 13 series and 3,035 total images. Multiple objective measures, subjective measures, and presence of key features were evaluated including program time to load, image time to load, cine/movie mode, ability to adequately window and level, pan and zoom functionality, basic measurement tools, and perceived lag when scrolling through a multi-image series. Substantial differences in speed of operation and behavior on multiple systems were documented, which could potentially add several minutes to the time required to open and view a patient's imaging data. The eFilm and iSite viewers operated consistently and reliably across all tested computer environments. The iSite viewer, having among the quickest load times in the group tested and consistently low subjective scroll lag during series viewing, and also beneficially allowing partial viewing while images load in the background, was found to generate the best overall user experience. Because of these significant differences, we have recommended that our institution standardize all patient imaging CD creation using the iSite viewer. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Journal of Digital Imaging is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=96967535
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10278-014-9675-2
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 4
        StartPage: 470
    Subjects:
      – SubjectFull: CD-ROMs
        Type: general
      – SubjectFull: Commercial product evaluation
        Type: general
      – SubjectFull: Computer graphics
        Type: general
      – SubjectFull: Patient education
        Type: general
      – SubjectFull: Picture archiving & communication systems
        Type: general
      – SubjectFull: Dicom (Computer network protocol)
        Type: general
    Titles:
      – TitleFull: Evaluation of Self-Contained PACS Viewers on CD-ROM.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Hosch, Richard
      – PersonEntity:
          Name:
            NameFull: Rivard, Andrew
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 08
              Text: Aug2014
              Type: published
              Y: 2014
          Identifiers:
            – Type: issn-print
              Value: 08971889
          Numbering:
            – Type: volume
              Value: 27
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: Journal of Digital Imaging
              Type: main
ResultId 1