Title: CT substitutes derived from MR images reconstructed with parallel imaging.
Authors: Johansson, Adam1, Garpebring, Anders2, Asklund, Thomas3, Nyholm, Tufve1
Source: Medical Physics. Aug2014, Vol. 41 Issue 8, p1-N.PAG. 7p.
Subjects: Computed tomography, Magnetic resonance imaging, k-spaces, Image processing, Statistical sampling, Radiotherapy, Medical imaging systems
Abstract: Purpose: Computed tomography (CT) substitute images can be generated from ultrashort echo time (UTE) MRI sequences with radial k-space sampling. These CT substitutes can be used as ordinary CT images for PET attenuation correction and radiotherapy dose calculations. Parallel imaging allows faster acquisition of magnetic resonance (MR) images by exploiting differences in receiver coil element sensitivities. This study investigates whether non-Cartesian parallel imaging reconstruction can be used to improve CT substitutes generated from shorter examination times. Methods: The authors used gridding as well as two non-Cartesian parallel imaging reconstruction methods, SPIRiT and CG-SENSE, to reconstruct radial UTE and gradient echo (GE) data into images of the head for 23 patients. For each patient, images were reconstructed from the full dataset and from a number of subsampled datasets. The subsampled datasets simulated shorter acquisition times by containing fewer radial k-space spokes (1000, 2000, 3000, 5000, and 10 000 spokes) than the full dataset (30 000 spokes). For each combination of patient, reconstruction method, and number of spokes, the reconstructed UTE and GE images were used to generate a CT substitute. Each CT substitute image was compared to a real CT image of the same patient. Results: The mean absolute deviation between the CT number in CT substitute and CT decreased when using SPIRiT as compared to gridding reconstruction. However, the reduction was small and the CT substitute algorithm was insensitive to moderate subsampling (≥5000 spokes) regardless of reconstruction method. For more severe subsampling (≤3000 spokes), corresponding to acquisition times less than aminute long, the CT substitute quality was deteriorated for all reconstructionmethods but SPIRiT gave a reduction in the mean absolute deviation of down to 25 Hounsfield units compared to gridding. Conclusions: SPIRiT marginally improved the CT substitute quality for a given number of radial spokes as compared to gridding. However, the increased reconstruction time of non-Cartesian parallel imaging reconstruction is difficult to motivate from this improvement. Because the CT substitute algorithm was insensitive to moderate subsampling, data for a CT substitute could be collected in as little as minute and reconstructed with gridding without deteriorating the CT substitute quality. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 97387007
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: CT substitutes derived from MR images reconstructed with parallel imaging.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Johansson%2C+Adam%22">Johansson, Adam</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Garpebring%2C+Anders%22">Garpebring, Anders</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Asklund%2C+Thomas%22">Asklund, Thomas</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Nyholm%2C+Tufve%22">Nyholm, Tufve</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Aug2014, Vol. 41 Issue 8, p1-N.PAG. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Magnetic+resonance+imaging%22">Magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22k-spaces%22">k-spaces</searchLink><br /><searchLink fieldCode="DE" term="%22Image+processing%22">Image processing</searchLink><br /><searchLink fieldCode="DE" term="%22Statistical+sampling%22">Statistical sampling</searchLink><br /><searchLink fieldCode="DE" term="%22Radiotherapy%22">Radiotherapy</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+imaging+systems%22">Medical imaging systems</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: Computed tomography (CT) substitute images can be generated from ultrashort echo time (UTE) MRI sequences with radial k-space sampling. These CT substitutes can be used as ordinary CT images for PET attenuation correction and radiotherapy dose calculations. Parallel imaging allows faster acquisition of magnetic resonance (MR) images by exploiting differences in receiver coil element sensitivities. This study investigates whether non-Cartesian parallel imaging reconstruction can be used to improve CT substitutes generated from shorter examination times. Methods: The authors used gridding as well as two non-Cartesian parallel imaging reconstruction methods, SPIRiT and CG-SENSE, to reconstruct radial UTE and gradient echo (GE) data into images of the head for 23 patients. For each patient, images were reconstructed from the full dataset and from a number of subsampled datasets. The subsampled datasets simulated shorter acquisition times by containing fewer radial k-space spokes (1000, 2000, 3000, 5000, and 10 000 spokes) than the full dataset (30 000 spokes). For each combination of patient, reconstruction method, and number of spokes, the reconstructed UTE and GE images were used to generate a CT substitute. Each CT substitute image was compared to a real CT image of the same patient. Results: The mean absolute deviation between the CT number in CT substitute and CT decreased when using SPIRiT as compared to gridding reconstruction. However, the reduction was small and the CT substitute algorithm was insensitive to moderate subsampling (≥5000 spokes) regardless of reconstruction method. For more severe subsampling (≤3000 spokes), corresponding to acquisition times less than aminute long, the CT substitute quality was deteriorated for all reconstructionmethods but SPIRiT gave a reduction in the mean absolute deviation of down to 25 Hounsfield units compared to gridding. Conclusions: SPIRiT marginally improved the CT substitute quality for a given number of radial spokes as compared to gridding. However, the increased reconstruction time of non-Cartesian parallel imaging reconstruction is difficult to motivate from this improvement. Because the CT substitute algorithm was insensitive to moderate subsampling, data for a CT substitute could be collected in as little as minute and reconstructed with gridding without deteriorating the CT substitute quality. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=97387007
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1118/1.4886766
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 1
    Subjects:
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: Magnetic resonance imaging
        Type: general
      – SubjectFull: k-spaces
        Type: general
      – SubjectFull: Image processing
        Type: general
      – SubjectFull: Statistical sampling
        Type: general
      – SubjectFull: Radiotherapy
        Type: general
      – SubjectFull: Medical imaging systems
        Type: general
    Titles:
      – TitleFull: CT substitutes derived from MR images reconstructed with parallel imaging.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Johansson, Adam
      – PersonEntity:
          Name:
            NameFull: Garpebring, Anders
      – PersonEntity:
          Name:
            NameFull: Asklund, Thomas
      – PersonEntity:
          Name:
            NameFull: Nyholm, Tufve
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 08
              Text: Aug2014
              Type: published
              Y: 2014
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 41
            – Type: issue
              Value: 8
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1