CT substitutes derived from MR images reconstructed with parallel imaging.
Saved in:
| Title: | CT substitutes derived from MR images reconstructed with parallel imaging. |
|---|---|
| Authors: | Johansson, Adam1, Garpebring, Anders2, Asklund, Thomas3, Nyholm, Tufve1 |
| Source: | Medical Physics. Aug2014, Vol. 41 Issue 8, p1-N.PAG. 7p. |
| Subjects: | Computed tomography, Magnetic resonance imaging, k-spaces, Image processing, Statistical sampling, Radiotherapy, Medical imaging systems |
| Abstract: | Purpose: Computed tomography (CT) substitute images can be generated from ultrashort echo time (UTE) MRI sequences with radial k-space sampling. These CT substitutes can be used as ordinary CT images for PET attenuation correction and radiotherapy dose calculations. Parallel imaging allows faster acquisition of magnetic resonance (MR) images by exploiting differences in receiver coil element sensitivities. This study investigates whether non-Cartesian parallel imaging reconstruction can be used to improve CT substitutes generated from shorter examination times. Methods: The authors used gridding as well as two non-Cartesian parallel imaging reconstruction methods, SPIRiT and CG-SENSE, to reconstruct radial UTE and gradient echo (GE) data into images of the head for 23 patients. For each patient, images were reconstructed from the full dataset and from a number of subsampled datasets. The subsampled datasets simulated shorter acquisition times by containing fewer radial k-space spokes (1000, 2000, 3000, 5000, and 10 000 spokes) than the full dataset (30 000 spokes). For each combination of patient, reconstruction method, and number of spokes, the reconstructed UTE and GE images were used to generate a CT substitute. Each CT substitute image was compared to a real CT image of the same patient. Results: The mean absolute deviation between the CT number in CT substitute and CT decreased when using SPIRiT as compared to gridding reconstruction. However, the reduction was small and the CT substitute algorithm was insensitive to moderate subsampling (≥5000 spokes) regardless of reconstruction method. For more severe subsampling (≤3000 spokes), corresponding to acquisition times less than aminute long, the CT substitute quality was deteriorated for all reconstructionmethods but SPIRiT gave a reduction in the mean absolute deviation of down to 25 Hounsfield units compared to gridding. Conclusions: SPIRiT marginally improved the CT substitute quality for a given number of radial spokes as compared to gridding. However, the increased reconstruction time of non-Cartesian parallel imaging reconstruction is difficult to motivate from this improvement. Because the CT substitute algorithm was insensitive to moderate subsampling, data for a CT substitute could be collected in as little as minute and reconstructed with gridding without deteriorating the CT substitute quality. [ABSTRACT FROM AUTHOR] |
| Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 97387007 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: CT substitutes derived from MR images reconstructed with parallel imaging. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Johansson%2C+Adam%22">Johansson, Adam</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Garpebring%2C+Anders%22">Garpebring, Anders</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Asklund%2C+Thomas%22">Asklund, Thomas</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Nyholm%2C+Tufve%22">Nyholm, Tufve</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Aug2014, Vol. 41 Issue 8, p1-N.PAG. 7p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Magnetic+resonance+imaging%22">Magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22k-spaces%22">k-spaces</searchLink><br /><searchLink fieldCode="DE" term="%22Image+processing%22">Image processing</searchLink><br /><searchLink fieldCode="DE" term="%22Statistical+sampling%22">Statistical sampling</searchLink><br /><searchLink fieldCode="DE" term="%22Radiotherapy%22">Radiotherapy</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+imaging+systems%22">Medical imaging systems</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: Computed tomography (CT) substitute images can be generated from ultrashort echo time (UTE) MRI sequences with radial k-space sampling. These CT substitutes can be used as ordinary CT images for PET attenuation correction and radiotherapy dose calculations. Parallel imaging allows faster acquisition of magnetic resonance (MR) images by exploiting differences in receiver coil element sensitivities. This study investigates whether non-Cartesian parallel imaging reconstruction can be used to improve CT substitutes generated from shorter examination times. Methods: The authors used gridding as well as two non-Cartesian parallel imaging reconstruction methods, SPIRiT and CG-SENSE, to reconstruct radial UTE and gradient echo (GE) data into images of the head for 23 patients. For each patient, images were reconstructed from the full dataset and from a number of subsampled datasets. The subsampled datasets simulated shorter acquisition times by containing fewer radial k-space spokes (1000, 2000, 3000, 5000, and 10 000 spokes) than the full dataset (30 000 spokes). For each combination of patient, reconstruction method, and number of spokes, the reconstructed UTE and GE images were used to generate a CT substitute. Each CT substitute image was compared to a real CT image of the same patient. Results: The mean absolute deviation between the CT number in CT substitute and CT decreased when using SPIRiT as compared to gridding reconstruction. However, the reduction was small and the CT substitute algorithm was insensitive to moderate subsampling (≥5000 spokes) regardless of reconstruction method. For more severe subsampling (≤3000 spokes), corresponding to acquisition times less than aminute long, the CT substitute quality was deteriorated for all reconstructionmethods but SPIRiT gave a reduction in the mean absolute deviation of down to 25 Hounsfield units compared to gridding. Conclusions: SPIRiT marginally improved the CT substitute quality for a given number of radial spokes as compared to gridding. However, the increased reconstruction time of non-Cartesian parallel imaging reconstruction is difficult to motivate from this improvement. Because the CT substitute algorithm was insensitive to moderate subsampling, data for a CT substitute could be collected in as little as minute and reconstructed with gridding without deteriorating the CT substitute quality. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=97387007 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1118/1.4886766 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 7 StartPage: 1 Subjects: – SubjectFull: Computed tomography Type: general – SubjectFull: Magnetic resonance imaging Type: general – SubjectFull: k-spaces Type: general – SubjectFull: Image processing Type: general – SubjectFull: Statistical sampling Type: general – SubjectFull: Radiotherapy Type: general – SubjectFull: Medical imaging systems Type: general Titles: – TitleFull: CT substitutes derived from MR images reconstructed with parallel imaging. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Johansson, Adam – PersonEntity: Name: NameFull: Garpebring, Anders – PersonEntity: Name: NameFull: Asklund, Thomas – PersonEntity: Name: NameFull: Nyholm, Tufve IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 08 Text: Aug2014 Type: published Y: 2014 Identifiers: – Type: issn-print Value: 00942405 Numbering: – Type: volume Value: 41 – Type: issue Value: 8 Titles: – TitleFull: Medical Physics Type: main |
| ResultId | 1 |