Inter-laboratory comparison of the analyses of sulphur hexafluoride (SF6) and three chlorofluorocarbons (CFC-11, -12 and -113) in groundwater and an air standard.

Saved in:
Bibliographic Details
Title: Inter-laboratory comparison of the analyses of sulphur hexafluoride (SF6) and three chlorofluorocarbons (CFC-11, -12 and -113) in groundwater and an air standard.
Authors: Labasque, T.1 thierry.labasque@univ-rennes1.fr, Aquilina, L.1, Vergnaud, V.1, Barbecot, F.2
Source: Applied Geochemistry. Nov2014, Vol. 50, p118-129. 12p.
Subjects: Sulfur hexafluoride, Chlorofluorocarbons, Groundwater recharge, Aquifers, Tracers (Chemistry), Analytical chemistry, Geochemistry
Abstract: An inter-laboratory comparison exercise involving the environmental tracers used for groundwater dating was organized in 2012 in France. This paper focuses on SF 6 and CFC tracers. Sampling and analytical protocols were compared in three different exercises using: (1) groundwater from a homogeneous aquifer, (2) groundwater from a fractured heterogeneous aquifer and (3) an air standard. The results show good agreement between laboratories (except some outliers) for the aquifers and air standard. Variation in the SF 6 results on the air standard was low (RSD = 2%) compared to CFCs (RSD 3–7%), even though its concentration was two orders of magnitude lower. Results obtained on recent groundwater (recharged post 1980) show that the inter-laboratory uncertainty for groundwater dating with SF 6 is 3–4 years. This large uncertainty is mainly due to sampling and/or analytical problems. For CFCs, the uncertainties obtained from all laboratories were less than 2 years for groundwater recharged between 1965 and 1996. A higher RSD was observed for CFCs with the air standard analysis, as compared to groundwater measurement, which could indicate an additional uncertainty due to inadequate standardization. Different sampling protocols were used by the laboratories (glass bottles, steel cylinders, etc.) but no systematic effect on measurement uncertainty could be attributed to any of these protocols for either CFCs or SF 6 . The better precisions obtained through these exercises indicate that, except for CFC-11 and SF 6 , the corresponding uncertainty in recharge date determination on recent groundwater (1993 – present) is higher than the commonly assumed 1–2 years (i.e., 7 years for CFC-12 and 4 years for CFC-113). These results confirm the need for regular inter-laboratory comparison exercises to improve the analytical and sampling procedures used in groundwater dating. [ABSTRACT FROM AUTHOR]
Copyright of Applied Geochemistry is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 99230572
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Inter-laboratory comparison of the analyses of sulphur hexafluoride (SF6) and three chlorofluorocarbons (CFC-11, -12 and -113) in groundwater and an air standard.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Labasque%2C+T%2E%22">Labasque, T.</searchLink><relatesTo>1</relatesTo><i> thierry.labasque@univ-rennes1.fr</i><br /><searchLink fieldCode="AR" term="%22Aquilina%2C+L%2E%22">Aquilina, L.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Vergnaud%2C+V%2E%22">Vergnaud, V.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Barbecot%2C+F%2E%22">Barbecot, F.</searchLink><relatesTo>2</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Applied+Geochemistry%22">Applied Geochemistry</searchLink>. Nov2014, Vol. 50, p118-129. 12p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Sulfur+hexafluoride%22">Sulfur hexafluoride</searchLink><br /><searchLink fieldCode="DE" term="%22Chlorofluorocarbons%22">Chlorofluorocarbons</searchLink><br /><searchLink fieldCode="DE" term="%22Groundwater+recharge%22">Groundwater recharge</searchLink><br /><searchLink fieldCode="DE" term="%22Aquifers%22">Aquifers</searchLink><br /><searchLink fieldCode="DE" term="%22Tracers+%28Chemistry%29%22">Tracers (Chemistry)</searchLink><br /><searchLink fieldCode="DE" term="%22Analytical+chemistry%22">Analytical chemistry</searchLink><br /><searchLink fieldCode="DE" term="%22Geochemistry%22">Geochemistry</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: An inter-laboratory comparison exercise involving the environmental tracers used for groundwater dating was organized in 2012 in France. This paper focuses on SF 6 and CFC tracers. Sampling and analytical protocols were compared in three different exercises using: (1) groundwater from a homogeneous aquifer, (2) groundwater from a fractured heterogeneous aquifer and (3) an air standard. The results show good agreement between laboratories (except some outliers) for the aquifers and air standard. Variation in the SF 6 results on the air standard was low (RSD = 2%) compared to CFCs (RSD 3–7%), even though its concentration was two orders of magnitude lower. Results obtained on recent groundwater (recharged post 1980) show that the inter-laboratory uncertainty for groundwater dating with SF 6 is 3–4 years. This large uncertainty is mainly due to sampling and/or analytical problems. For CFCs, the uncertainties obtained from all laboratories were less than 2 years for groundwater recharged between 1965 and 1996. A higher RSD was observed for CFCs with the air standard analysis, as compared to groundwater measurement, which could indicate an additional uncertainty due to inadequate standardization. Different sampling protocols were used by the laboratories (glass bottles, steel cylinders, etc.) but no systematic effect on measurement uncertainty could be attributed to any of these protocols for either CFCs or SF 6 . The better precisions obtained through these exercises indicate that, except for CFC-11 and SF 6 , the corresponding uncertainty in recharge date determination on recent groundwater (1993 – present) is higher than the commonly assumed 1–2 years (i.e., 7 years for CFC-12 and 4 years for CFC-113). These results confirm the need for regular inter-laboratory comparison exercises to improve the analytical and sampling procedures used in groundwater dating. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Applied Geochemistry is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=99230572
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.apgeochem.2014.03.009
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 12
        StartPage: 118
    Subjects:
      – SubjectFull: Sulfur hexafluoride
        Type: general
      – SubjectFull: Chlorofluorocarbons
        Type: general
      – SubjectFull: Groundwater recharge
        Type: general
      – SubjectFull: Aquifers
        Type: general
      – SubjectFull: Tracers (Chemistry)
        Type: general
      – SubjectFull: Analytical chemistry
        Type: general
      – SubjectFull: Geochemistry
        Type: general
    Titles:
      – TitleFull: Inter-laboratory comparison of the analyses of sulphur hexafluoride (SF6) and three chlorofluorocarbons (CFC-11, -12 and -113) in groundwater and an air standard.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Labasque, T.
      – PersonEntity:
          Name:
            NameFull: Aquilina, L.
      – PersonEntity:
          Name:
            NameFull: Vergnaud, V.
      – PersonEntity:
          Name:
            NameFull: Barbecot, F.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2014
              Type: published
              Y: 2014
          Identifiers:
            – Type: issn-print
              Value: 08832927
          Numbering:
            – Type: volume
              Value: 50
          Titles:
            – TitleFull: Applied Geochemistry
              Type: main
ResultId 1