Traceability of DC and AC high voltage measurements using voltage divider calibration.

Saved in:
Bibliographic Details
Title: Traceability of DC and AC high voltage measurements using voltage divider calibration.
Authors: Abdel Mageed, Hala M.1 Halaabdelmegeed@yahoo.com, Alenezi, Faisal Q.2
Source: International Journal of Electrical Engineering Education. Apr2018, Vol. 55 Issue 2, p109-119. 11p. 1 Color Photograph, 2 Diagrams, 8 Charts, 2 Graphs.
Subject Terms: *Engineering education, High voltages, Voltmeters, Alternating currents, Direct currents, Electric capacity
Abstract: This paper focuses on achieving traceability of high voltage measurements up to 200 kV at the Egyptian National Institute of Standards. The measurement system consists of an AC/DC voltmeter and a universal resistive/capacitive high voltage divider. The voltmeter shows measured voltage values based on the scale factor of the voltage divider. The divider ensures a stable capacitance for AC voltage measurements and an additional resistive parallel path for DC voltage measurements. Both the divider and the voltmeter are calibrated in AC and DC modes. All uncertainty components are taken into account to obtain measured values with an acceptable accuracy. The calibration results in traceability to the national standards, which make measurements using the international system of units. The proposed calibration method is useful for the theory and practice of high voltage measurements in education, industrial applications, and electrical metrology studies. [ABSTRACT FROM AUTHOR]
Copyright of International Journal of Electrical Engineering Education is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Education Research Complete
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: ehh
DbLabel: Education Research Complete
An: 128981165
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Traceability of DC and AC high voltage measurements using voltage divider calibration.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Abdel+Mageed%2C+Hala+M%2E%22">Abdel Mageed, Hala M.</searchLink><relatesTo>1</relatesTo><i> Halaabdelmegeed@yahoo.com</i><br /><searchLink fieldCode="AR" term="%22Alenezi%2C+Faisal+Q%2E%22">Alenezi, Faisal Q.</searchLink><relatesTo>2</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22International+Journal+of+Electrical+Engineering+Education%22">International Journal of Electrical Engineering Education</searchLink>. Apr2018, Vol. 55 Issue 2, p109-119. 11p. 1 Color Photograph, 2 Diagrams, 8 Charts, 2 Graphs.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Engineering+education%22">Engineering education</searchLink><br /><searchLink fieldCode="DE" term="%22High+voltages%22">High voltages</searchLink><br /><searchLink fieldCode="DE" term="%22Voltmeters%22">Voltmeters</searchLink><br /><searchLink fieldCode="DE" term="%22Alternating+currents%22">Alternating currents</searchLink><br /><searchLink fieldCode="DE" term="%22Direct+currents%22">Direct currents</searchLink><br /><searchLink fieldCode="DE" term="%22Electric+capacity%22">Electric capacity</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: This paper focuses on achieving traceability of high voltage measurements up to 200 kV at the Egyptian National Institute of Standards. The measurement system consists of an AC/DC voltmeter and a universal resistive/capacitive high voltage divider. The voltmeter shows measured voltage values based on the scale factor of the voltage divider. The divider ensures a stable capacitance for AC voltage measurements and an additional resistive parallel path for DC voltage measurements. Both the divider and the voltmeter are calibrated in AC and DC modes. All uncertainty components are taken into account to obtain measured values with an acceptable accuracy. The calibration results in traceability to the national standards, which make measurements using the international system of units. The proposed calibration method is useful for the theory and practice of high voltage measurements in education, industrial applications, and electrical metrology studies. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of International Journal of Electrical Engineering Education is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=ehh&AN=128981165
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1177/0020720918754832
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 109
    Subjects:
      – SubjectFull: Engineering education
        Type: general
      – SubjectFull: High voltages
        Type: general
      – SubjectFull: Voltmeters
        Type: general
      – SubjectFull: Alternating currents
        Type: general
      – SubjectFull: Direct currents
        Type: general
      – SubjectFull: Electric capacity
        Type: general
    Titles:
      – TitleFull: Traceability of DC and AC high voltage measurements using voltage divider calibration.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Abdel Mageed, Hala M.
      – PersonEntity:
          Name:
            NameFull: Alenezi, Faisal Q.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2018
              Type: published
              Y: 2018
          Identifiers:
            – Type: issn-print
              Value: 00207209
          Numbering:
            – Type: volume
              Value: 55
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: International Journal of Electrical Engineering Education
              Type: main
ResultId 1