Eficiencia De Método Convencional De Protección Contra La Corrosión En Aceros ASTM A36 En Medio Salino.
Saved in:
| Title: | Eficiencia De Método Convencional De Protección Contra La Corrosión En Aceros ASTM A36 En Medio Salino. |
|---|---|
| Alternate Title: | Efficiency of Conventional Method of Protection Against Corrosion in ASTM A36 Steels in Saline Medium. |
| Authors: | Freire, E. Calderón1 edisson.calderon@espoch.edu.ec, García, A. Tenicota1, Redroban, C.2, Vega, J. Caiza3, Rodriguez, F. Gamboa3 |
| Source: | ESPOCH Congresses: The Ecuadorian Journal of S.T.E.A.M.. 2023, Vol. 3 Issue 3, p179-192. 14p. |
| Abstract (English): | This study aims to compare the performance of three anti-corrosion protection methods and estimate the corrosion rate according to the ASTM G1-03 standard in ASTM A36 steel plates. The applied methodology follows the procedure established in the ASTM G31-21 and ASTM G1-03 standards. While a chemical solution based on the ASTM G44 standards was used for corrosion. The corrosion rate was carried out by calculating the optimal sample size of the number of steel witness plates A36 to be immersed in a 3.5% sodium chloride solution, placed in 4 polypropylene vats, simulating the corrosive environment under conditions containing a pH between 6-7 and a temperature between 25-30°C. For the first method, a polymeric coating was applied according to the SSPC-PA 1 standard using high-volume solids epoxy paints with a corrosion rate of 0.0502 mm/year. In the second method, cathodic protection was applied by sacrificial anode on the witness plates obtaining a speed of 0.0275 mm/year. The third method used a sacrificial anode by an impressed current in which an external source was used to circulate current between the anode and cathode, resulting in 0.0096 mm/year. [ABSTRACT FROM AUTHOR] |
| Abstract (Spanish): | El objetivo de este estudio fue comparar el rendimiento de tres métodos de protección anticorrosiva y estimar la velocidad de corrosión según la norma ASTM G1-03 en placas de acero ASTMA36. La metodología aplicada sigue el procedimiento establecido en las normas ASTM G31-21 y ASTM G1-03, mientras que para la corrosión se utilizó una solución química basada en las normas ASTM G44. La velocidad de corrosión se llevó a cabo mediante el cálculo del tamaño de muestra óptimo de número de placas testigos de acero A36 a sumergir en una solución de cloruro de sodio al 3.5%, colocado en 4 cubas de polipropileno, simulando el ambiente corrosivo en condiciones que contenían un pH entre 6-7 y una temperatura entre 25-30°C. Como primera instancia en el primer método se aplicó un recubrimiento polimérico según la norma SSPC-PA 1 mediante pinturas epóxicas de alto sólidos en volumen teniendo una velocidad de corrosión de 0.0502 mm/año, en el segundo método se aplicó protección catódica por ánodo de sacrificio en las placas testigos obteniendo una velocidad de 0,0275 mm/año y para el tercer método se empleó un ánodo de sacrificio por corriente impresa en el cual utilizaremos una fuente externa para hacer circular corriente entre el ánodo y cátodo, teniendo como resultado 0,0096 mm/año. [ABSTRACT FROM AUTHOR] |
| Copyright of ESPOCH Congresses: The Ecuadorian Journal of S.T.E.A.M. is the property of Knowledge E DMCC and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Education Research Complete |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: ehh DbLabel: Education Research Complete An: 178981236 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Eficiencia De Método Convencional De Protección Contra La Corrosión En Aceros ASTM A36 En Medio Salino. – Name: TitleAlt Label: Alternate Title Group: TiAlt Data: Efficiency of Conventional Method of Protection Against Corrosion in ASTM A36 Steels in Saline Medium. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Freire%2C+E%2E+Calderón%22">Freire, E. Calderón</searchLink><relatesTo>1</relatesTo><i> edisson.calderon@espoch.edu.ec</i><br /><searchLink fieldCode="AR" term="%22García%2C+A%2E+Tenicota%22">García, A. Tenicota</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Redroban%2C+C%2E%22">Redroban, C.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Vega%2C+J%2E+Caiza%22">Vega, J. Caiza</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Rodriguez%2C+F%2E+Gamboa%22">Rodriguez, F. Gamboa</searchLink><relatesTo>3</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22ESPOCH+Congresses%3A+The+Ecuadorian+Journal+of+S%2ET%2EE%2EA%2EM%2E%22">ESPOCH Congresses: The Ecuadorian Journal of S.T.E.A.M.</searchLink>. 2023, Vol. 3 Issue 3, p179-192. 14p. – Name: Abstract Label: Abstract (English) Group: Ab Data: This study aims to compare the performance of three anti-corrosion protection methods and estimate the corrosion rate according to the ASTM G1-03 standard in ASTM A36 steel plates. The applied methodology follows the procedure established in the ASTM G31-21 and ASTM G1-03 standards. While a chemical solution based on the ASTM G44 standards was used for corrosion. The corrosion rate was carried out by calculating the optimal sample size of the number of steel witness plates A36 to be immersed in a 3.5% sodium chloride solution, placed in 4 polypropylene vats, simulating the corrosive environment under conditions containing a pH between 6-7 and a temperature between 25-30°C. For the first method, a polymeric coating was applied according to the SSPC-PA 1 standard using high-volume solids epoxy paints with a corrosion rate of 0.0502 mm/year. In the second method, cathodic protection was applied by sacrificial anode on the witness plates obtaining a speed of 0.0275 mm/year. The third method used a sacrificial anode by an impressed current in which an external source was used to circulate current between the anode and cathode, resulting in 0.0096 mm/year. [ABSTRACT FROM AUTHOR] – Name: Abstract Label: Abstract (Spanish) Group: Ab Data: El objetivo de este estudio fue comparar el rendimiento de tres métodos de protección anticorrosiva y estimar la velocidad de corrosión según la norma ASTM G1-03 en placas de acero ASTMA36. La metodología aplicada sigue el procedimiento establecido en las normas ASTM G31-21 y ASTM G1-03, mientras que para la corrosión se utilizó una solución química basada en las normas ASTM G44. La velocidad de corrosión se llevó a cabo mediante el cálculo del tamaño de muestra óptimo de número de placas testigos de acero A36 a sumergir en una solución de cloruro de sodio al 3.5%, colocado en 4 cubas de polipropileno, simulando el ambiente corrosivo en condiciones que contenían un pH entre 6-7 y una temperatura entre 25-30°C. Como primera instancia en el primer método se aplicó un recubrimiento polimérico según la norma SSPC-PA 1 mediante pinturas epóxicas de alto sólidos en volumen teniendo una velocidad de corrosión de 0.0502 mm/año, en el segundo método se aplicó protección catódica por ánodo de sacrificio en las placas testigos obteniendo una velocidad de 0,0275 mm/año y para el tercer método se empleó un ánodo de sacrificio por corriente impresa en el cual utilizaremos una fuente externa para hacer circular corriente entre el ánodo y cátodo, teniendo como resultado 0,0096 mm/año. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of ESPOCH Congresses: The Ecuadorian Journal of S.T.E.A.M. is the property of Knowledge E DMCC and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=ehh&AN=178981236 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.18502/espoch.v3i3.16621 Languages: – Code: spa Text: Spanish PhysicalDescription: Pagination: PageCount: 14 StartPage: 179 Titles: – TitleFull: Eficiencia De Método Convencional De Protección Contra La Corrosión En Aceros ASTM A36 En Medio Salino. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Freire, E. Calderón – PersonEntity: Name: NameFull: García, A. Tenicota – PersonEntity: Name: NameFull: Redroban, C. – PersonEntity: Name: NameFull: Vega, J. Caiza – PersonEntity: Name: NameFull: Rodriguez, F. Gamboa IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 05 Text: 2023 Type: published Y: 2023 Identifiers: – Type: issn-print Value: 27895009 Numbering: – Type: volume Value: 3 – Type: issue Value: 3 Titles: – TitleFull: ESPOCH Congresses: The Ecuadorian Journal of S.T.E.A.M. Type: main |
| ResultId | 1 |