Rational random walk-based optimal placement of phasor measurement units to enhance the initializing and guiding the optimization processes.

Saved in:
Bibliographic Details
Title: Rational random walk-based optimal placement of phasor measurement units to enhance the initializing and guiding the optimization processes.
Authors: Parpaei, Mohammad1, Ghaffarzadeh, Navid1 ghaffarzadeh@eng.ikiu.ac.ir, Tayar, Mirza Zuhaib1
Source: International Transactions on Electrical Energy Systems. Jul2017, Vol. 27 Issue 7, pn/a-N.PAG. 11p.
Subject Terms: *Phasor measurement, *Random walks, *Electric potential
Abstract: Phasor measurement unit (PMU) is one of the state estimation devices that can synchronously measure both the voltage and the current phasor. Different methods have been presented for detecting the optimal number of PMUs. Some disadvantages of these methods are high computation burden, dependence on tuning parameters, complex calculation, and lack of accountability in large-scale power networks. This paper presents the novel strategy called rational random walk (RRW) to tackle these disadvantages. The first advantage of the proposed approach is the simple structure than conventional approaches. The second advantage is the independence of tuning parameters. The third advantage is the capability of implementation on the large-scale power networks. The fourth advantage is the use of 2-stage strategy for reducing the search space. The fifth advantage is capability of RRW to superimpose on the conventional optimization algorithm to enhance the convergence speed. The sixth advantage is capability of RRW to extract the optimal PMU placement under N-1 contingency. Superiority of the RRW in comparison with other methods is verified by implementing on the standard Institute of Electrical and Electronics Engineers (IEEE) test systems. Moreover, the proposed method has been used to specify and test the minimum number of PMUs in 2 real life systems in Iran power network. One of them is 400 kV, and the other one is 230 kV, and also a large-scale test system polish 2383-bus power system. [ABSTRACT FROM AUTHOR]
Database: Energy & Power Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: enr
DbLabel: Energy & Power Source
An: 124072300
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Rational random walk-based optimal placement of phasor measurement units to enhance the initializing and guiding the optimization processes.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Parpaei%2C+Mohammad%22">Parpaei, Mohammad</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Ghaffarzadeh%2C+Navid%22">Ghaffarzadeh, Navid</searchLink><relatesTo>1</relatesTo><i> ghaffarzadeh@eng.ikiu.ac.ir</i><br /><searchLink fieldCode="AR" term="%22Tayar%2C+Mirza+Zuhaib%22">Tayar, Mirza Zuhaib</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22International+Transactions+on+Electrical+Energy+Systems%22">International Transactions on Electrical Energy Systems</searchLink>. Jul2017, Vol. 27 Issue 7, pn/a-N.PAG. 11p.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Phasor+measurement%22">Phasor measurement</searchLink><br />*<searchLink fieldCode="DE" term="%22Random+walks%22">Random walks</searchLink><br />*<searchLink fieldCode="DE" term="%22Electric+potential%22">Electric potential</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Phasor measurement unit (PMU) is one of the state estimation devices that can synchronously measure both the voltage and the current phasor. Different methods have been presented for detecting the optimal number of PMUs. Some disadvantages of these methods are high computation burden, dependence on tuning parameters, complex calculation, and lack of accountability in large-scale power networks. This paper presents the novel strategy called rational random walk (RRW) to tackle these disadvantages. The first advantage of the proposed approach is the simple structure than conventional approaches. The second advantage is the independence of tuning parameters. The third advantage is the capability of implementation on the large-scale power networks. The fourth advantage is the use of 2-stage strategy for reducing the search space. The fifth advantage is capability of RRW to superimpose on the conventional optimization algorithm to enhance the convergence speed. The sixth advantage is capability of RRW to extract the optimal PMU placement under N-1 contingency. Superiority of the RRW in comparison with other methods is verified by implementing on the standard Institute of Electrical and Electronics Engineers (IEEE) test systems. Moreover, the proposed method has been used to specify and test the minimum number of PMUs in 2 real life systems in Iran power network. One of them is 400 kV, and the other one is 230 kV, and also a large-scale test system polish 2383-bus power system. [ABSTRACT FROM AUTHOR]
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=124072300
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/etep.2323
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: n/a
    Subjects:
      – SubjectFull: Phasor measurement
        Type: general
      – SubjectFull: Random walks
        Type: general
      – SubjectFull: Electric potential
        Type: general
    Titles:
      – TitleFull: Rational random walk-based optimal placement of phasor measurement units to enhance the initializing and guiding the optimization processes.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Parpaei, Mohammad
      – PersonEntity:
          Name:
            NameFull: Ghaffarzadeh, Navid
      – PersonEntity:
          Name:
            NameFull: Tayar, Mirza Zuhaib
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 07
              Text: Jul2017
              Type: published
              Y: 2017
          Identifiers:
            – Type: issn-print
              Value: 20507038
          Numbering:
            – Type: volume
              Value: 27
            – Type: issue
              Value: 7
          Titles:
            – TitleFull: International Transactions on Electrical Energy Systems
              Type: main
ResultId 1