Phasor Estimation of Transient Electrical Signals Using Modified Covariance Enhanced Cleaned Characteristic Harmonic Filtering in Protection Relay.
Saved in:
| Title: | Phasor Estimation of Transient Electrical Signals Using Modified Covariance Enhanced Cleaned Characteristic Harmonic Filtering in Protection Relay. |
|---|---|
| Authors: | Alwan, Natheer1 (AUTHOR) natheeralwan@gmail.com, Papic, Veljko1 (AUTHOR) |
| Source: | Energies (19961073). Feb2026, Vol. 19 Issue 3, p711. 28p. |
| Subject Terms: | *Protective relays, *Signal frequency estimation, *Phasor measurement, *Signal processing, *Electric transients |
| Abstract: | Modern protection relays require accurate and fast phasor estimation under harsh transient conditions, including a decaying DC component, harmonics, interharmonics, noise, and frequency instability. The original CCHDF (Cleaned Characteristic Harmonic Digital Filter) produced a harmonic cleaned signal using the Biunivocal Frequency Relationship of Phasors (BFRP) technique, but relied on DFT, Hanning windowing, and peak detection to identify interharmonic components. This paper replaces that spectral estimation block with the Modified Covariance Method (MCM) estimator, a high resolution autoregressive (AR) spectral estimator capable of superior frequency, magnitude, and phase estimation of non-harmonic components even with a short data window. The result is an improved filter named MCCCHDF (Modified Covariance CCHDF), preserving the original algorithmic pipeline, but achieving higher accuracy and faster convergence in the presence of closely spaced harmonics/interharmonics and noisy decaying DC conditions. [ABSTRACT FROM AUTHOR] |
| Database: | Energy & Power Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: enr DbLabel: Energy & Power Source An: 191587190 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Phasor Estimation of Transient Electrical Signals Using Modified Covariance Enhanced Cleaned Characteristic Harmonic Filtering in Protection Relay. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Alwan%2C+Natheer%22">Alwan, Natheer</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> natheeralwan@gmail.com</i><br /><searchLink fieldCode="AR" term="%22Papic%2C+Veljko%22">Papic, Veljko</searchLink><relatesTo>1</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Energies+%2819961073%29%22">Energies (19961073)</searchLink>. Feb2026, Vol. 19 Issue 3, p711. 28p. – Name: Subject Label: Subject Terms Group: Su Data: *<searchLink fieldCode="DE" term="%22Protective+relays%22">Protective relays</searchLink><br />*<searchLink fieldCode="DE" term="%22Signal+frequency+estimation%22">Signal frequency estimation</searchLink><br />*<searchLink fieldCode="DE" term="%22Phasor+measurement%22">Phasor measurement</searchLink><br />*<searchLink fieldCode="DE" term="%22Signal+processing%22">Signal processing</searchLink><br />*<searchLink fieldCode="DE" term="%22Electric+transients%22">Electric transients</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Modern protection relays require accurate and fast phasor estimation under harsh transient conditions, including a decaying DC component, harmonics, interharmonics, noise, and frequency instability. The original CCHDF (Cleaned Characteristic Harmonic Digital Filter) produced a harmonic cleaned signal using the Biunivocal Frequency Relationship of Phasors (BFRP) technique, but relied on DFT, Hanning windowing, and peak detection to identify interharmonic components. This paper replaces that spectral estimation block with the Modified Covariance Method (MCM) estimator, a high resolution autoregressive (AR) spectral estimator capable of superior frequency, magnitude, and phase estimation of non-harmonic components even with a short data window. The result is an improved filter named MCCCHDF (Modified Covariance CCHDF), preserving the original algorithmic pipeline, but achieving higher accuracy and faster convergence in the presence of closely spaced harmonics/interharmonics and noisy decaying DC conditions. [ABSTRACT FROM AUTHOR] |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=191587190 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.3390/en19030711 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 28 StartPage: 711 Subjects: – SubjectFull: Protective relays Type: general – SubjectFull: Signal frequency estimation Type: general – SubjectFull: Phasor measurement Type: general – SubjectFull: Signal processing Type: general – SubjectFull: Electric transients Type: general Titles: – TitleFull: Phasor Estimation of Transient Electrical Signals Using Modified Covariance Enhanced Cleaned Characteristic Harmonic Filtering in Protection Relay. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Alwan, Natheer – PersonEntity: Name: NameFull: Papic, Veljko IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 02 Text: Feb2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 19961073 Numbering: – Type: volume Value: 19 – Type: issue Value: 3 Titles: – TitleFull: Energies (19961073) Type: main |
| ResultId | 1 |