Modulation with Full-Range Zero Voltage Switching and Current Peak Optimization for AC–DC Converter.
Saved in:
| Title: | Modulation with Full-Range Zero Voltage Switching and Current Peak Optimization for AC–DC Converter. |
|---|---|
| Authors: | Shi, Lingling1 (AUTHOR), Li, Zexing2 (AUTHOR), Wang, Ke1,3 (AUTHOR), Shen, Hui1 (AUTHOR), Wu, Zhe1,2 (AUTHOR), Wang, Yaoqiang3 (AUTHOR) wangyqee@163.com |
| Source: | Energies (19961073). Feb2026, Vol. 19 Issue 4, p948. 17p. |
| Subject Terms: | *Zero voltage switching, *Phase modulation, *Power electronics, *AC DC transformers |
| Abstract: | To address the issues of limited soft-switching range and high inductor current peak in traditional single phase shift (SPS) modulation for AC–DC converters under a wide range of voltage conversion ratio conditions, this paper proposes an optimized modulation strategy based on SPS modulation. First, the steady-state operating characteristics under SPS modulation are analyzed, and the current-transfer equation is derived. A conversion coefficient is then introduced to transform the conventional phase-shift ratio into a new variable. Based on this, the time-domain characteristics of the inductor current peak and the constraints for zero voltage switching (ZVS) are analyzed. An analytical expression of the conversion coefficient is obtained, which ensures ZVS operation for all switches in the dual-active-bridge (DAB) converter and minimizes the inductor current peak. Finally, experiments verify the effectiveness and feasibility of the proposed modulation strategy. [ABSTRACT FROM AUTHOR] |
| Database: | Energy & Power Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: enr DbLabel: Energy & Power Source An: 191973368 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Modulation with Full-Range Zero Voltage Switching and Current Peak Optimization for AC–DC Converter. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Shi%2C+Lingling%22">Shi, Lingling</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Li%2C+Zexing%22">Li, Zexing</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wang%2C+Ke%22">Wang, Ke</searchLink><relatesTo>1,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Shen%2C+Hui%22">Shen, Hui</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wu%2C+Zhe%22">Wu, Zhe</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wang%2C+Yaoqiang%22">Wang, Yaoqiang</searchLink><relatesTo>3</relatesTo> (AUTHOR)<i> wangyqee@163.com</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Energies+%2819961073%29%22">Energies (19961073)</searchLink>. Feb2026, Vol. 19 Issue 4, p948. 17p. – Name: Subject Label: Subject Terms Group: Su Data: *<searchLink fieldCode="DE" term="%22Zero+voltage+switching%22">Zero voltage switching</searchLink><br />*<searchLink fieldCode="DE" term="%22Phase+modulation%22">Phase modulation</searchLink><br />*<searchLink fieldCode="DE" term="%22Power+electronics%22">Power electronics</searchLink><br />*<searchLink fieldCode="DE" term="%22AC+DC+transformers%22">AC DC transformers</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: To address the issues of limited soft-switching range and high inductor current peak in traditional single phase shift (SPS) modulation for AC–DC converters under a wide range of voltage conversion ratio conditions, this paper proposes an optimized modulation strategy based on SPS modulation. First, the steady-state operating characteristics under SPS modulation are analyzed, and the current-transfer equation is derived. A conversion coefficient is then introduced to transform the conventional phase-shift ratio into a new variable. Based on this, the time-domain characteristics of the inductor current peak and the constraints for zero voltage switching (ZVS) are analyzed. An analytical expression of the conversion coefficient is obtained, which ensures ZVS operation for all switches in the dual-active-bridge (DAB) converter and minimizes the inductor current peak. Finally, experiments verify the effectiveness and feasibility of the proposed modulation strategy. [ABSTRACT FROM AUTHOR] |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=191973368 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.3390/en19040948 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 17 StartPage: 948 Subjects: – SubjectFull: Zero voltage switching Type: general – SubjectFull: Phase modulation Type: general – SubjectFull: Power electronics Type: general – SubjectFull: AC DC transformers Type: general Titles: – TitleFull: Modulation with Full-Range Zero Voltage Switching and Current Peak Optimization for AC–DC Converter. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Shi, Lingling – PersonEntity: Name: NameFull: Li, Zexing – PersonEntity: Name: NameFull: Wang, Ke – PersonEntity: Name: NameFull: Shen, Hui – PersonEntity: Name: NameFull: Wu, Zhe – PersonEntity: Name: NameFull: Wang, Yaoqiang IsPartOfRelationships: – BibEntity: Dates: – D: 15 M: 02 Text: Feb2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 19961073 Numbering: – Type: volume Value: 19 – Type: issue Value: 4 Titles: – TitleFull: Energies (19961073) Type: main |
| ResultId | 1 |