Forest Fire Susceptibility Mapping of West Sikkim District, India using MCDA techniques.

Saved in:
Bibliographic Details
Title: Forest Fire Susceptibility Mapping of West Sikkim District, India using MCDA techniques.
Authors: Naskar, Suvankar1 (AUTHOR), Rahaman, Aneesah2 (AUTHOR), Biswas, Brototi1 (AUTHOR) brototibiswas@gmail.com
Source: Environment, Development & Sustainability. Mar2026, Vol. 28 Issue 3, p7443-7468. 26p.
Subject Terms: *Fire risk assessment, *Multiple criteria decision making, *ASTER (Advanced spaceborne thermal emission & reflection radiometer), *TOPSIS method, *Geoinformatics, *Analytic hierarchy process
Geographic Terms: India, Sikkim (India)
Abstract: Forest fire poses a major environmental hazard, to the extent of sometimes permanently damaging the forest ecology. The potential of human to repair nature is hampered by the extension of human domination into forests, which results in the loss of forest land. While human expansion cannot be stopped, we must accept responsibility for the consequences and thus work to minimize such environmental hazards emanating from such calamities. RS and GIS have proved to be useful techniques for such studies. The goal of the current study is to identify the most vulnerable forest fire zones in the West Sikkim district falling within the state of Sikkim (India) during 2004–2021. Various thematic layers (LULC and topographical factors) were created using Landsat 8 OLI and ASTER DEM. For the final forest fire susceptibility zone (FFSZ) map, climate variables such as precipitation, temperature, humidity, and wind speed were also used. The authors employed the MCDM techniques of AHP and TOPSIS to determine the areas which are most vulnerable to wildfires in the research area. 194 wildfire locations, as obtained from Sikkim State Disaster Management Authority (SDMA) were used for the classification. The FFSZ were classified as "very high, high, medium, low, and very low vulnerability zones" based on their fire vulnerability. The areas under the "Very High Susceptibility Zone" of AHP and TOPSIS were 152.331 km2 and 348.499 km2 respectively whereas the areas under "Very Low Susceptibility Zone" were 115.351 km2 and 139.436 km2 in the results of AHP and TOPSIS respectively. To check the accuracy of the FFSZ susceptibility maps obtained from the two modelling techniques, the same was confirmed by using (Receiver Operating Characteristics) ROC curves. The result indicates that the TOPSIS model (AUC = 82.28%) is slightly better at determining the vulnerable zones than the AHP method (AUC = 72.25%). [ABSTRACT FROM AUTHOR]
Database: Energy & Power Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: enr
DbLabel: Energy & Power Source
An: 192417995
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Forest Fire Susceptibility Mapping of West Sikkim District, India using MCDA techniques.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Naskar%2C+Suvankar%22">Naskar, Suvankar</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Rahaman%2C+Aneesah%22">Rahaman, Aneesah</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Biswas%2C+Brototi%22">Biswas, Brototi</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> brototibiswas@gmail.com</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Environment%2C+Development+%26+Sustainability%22">Environment, Development & Sustainability</searchLink>. Mar2026, Vol. 28 Issue 3, p7443-7468. 26p.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Fire+risk+assessment%22">Fire risk assessment</searchLink><br />*<searchLink fieldCode="DE" term="%22Multiple+criteria+decision+making%22">Multiple criteria decision making</searchLink><br />*<searchLink fieldCode="DE" term="%22ASTER+%28Advanced+spaceborne+thermal+emission+%26+reflection+radiometer%29%22">ASTER (Advanced spaceborne thermal emission & reflection radiometer)</searchLink><br />*<searchLink fieldCode="DE" term="%22TOPSIS+method%22">TOPSIS method</searchLink><br />*<searchLink fieldCode="DE" term="%22Geoinformatics%22">Geoinformatics</searchLink><br />*<searchLink fieldCode="DE" term="%22Analytic+hierarchy+process%22">Analytic hierarchy process</searchLink>
– Name: SubjectGeographic
  Label: Geographic Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22India%22">India</searchLink><br /><searchLink fieldCode="DE" term="%22Sikkim+%28India%29%22">Sikkim (India)</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Forest fire poses a major environmental hazard, to the extent of sometimes permanently damaging the forest ecology. The potential of human to repair nature is hampered by the extension of human domination into forests, which results in the loss of forest land. While human expansion cannot be stopped, we must accept responsibility for the consequences and thus work to minimize such environmental hazards emanating from such calamities. RS and GIS have proved to be useful techniques for such studies. The goal of the current study is to identify the most vulnerable forest fire zones in the West Sikkim district falling within the state of Sikkim (India) during 2004–2021. Various thematic layers (LULC and topographical factors) were created using Landsat 8 OLI and ASTER DEM. For the final forest fire susceptibility zone (FFSZ) map, climate variables such as precipitation, temperature, humidity, and wind speed were also used. The authors employed the MCDM techniques of AHP and TOPSIS to determine the areas which are most vulnerable to wildfires in the research area. 194 wildfire locations, as obtained from Sikkim State Disaster Management Authority (SDMA) were used for the classification. The FFSZ were classified as "very high, high, medium, low, and very low vulnerability zones" based on their fire vulnerability. The areas under the "Very High Susceptibility Zone" of AHP and TOPSIS were 152.331 km2 and 348.499 km2 respectively whereas the areas under "Very Low Susceptibility Zone" were 115.351 km2 and 139.436 km2 in the results of AHP and TOPSIS respectively. To check the accuracy of the FFSZ susceptibility maps obtained from the two modelling techniques, the same was confirmed by using (Receiver Operating Characteristics) ROC curves. The result indicates that the TOPSIS model (AUC = 82.28%) is slightly better at determining the vulnerable zones than the AHP method (AUC = 72.25%). [ABSTRACT FROM AUTHOR]
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=192417995
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10668-024-05158-4
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 26
        StartPage: 7443
    Subjects:
      – SubjectFull: Fire risk assessment
        Type: general
      – SubjectFull: Multiple criteria decision making
        Type: general
      – SubjectFull: ASTER (Advanced spaceborne thermal emission & reflection radiometer)
        Type: general
      – SubjectFull: TOPSIS method
        Type: general
      – SubjectFull: Geoinformatics
        Type: general
      – SubjectFull: Analytic hierarchy process
        Type: general
      – SubjectFull: India
        Type: general
      – SubjectFull: Sikkim (India)
        Type: general
    Titles:
      – TitleFull: Forest Fire Susceptibility Mapping of West Sikkim District, India using MCDA techniques.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Naskar, Suvankar
      – PersonEntity:
          Name:
            NameFull: Rahaman, Aneesah
      – PersonEntity:
          Name:
            NameFull: Biswas, Brototi
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: Mar2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 1387585X
          Numbering:
            – Type: volume
              Value: 28
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Environment, Development & Sustainability
              Type: main
ResultId 1