Technical note: Efficiency of various evaporation barriers for use in automated water samplers for subsequent water isotope analysis.

Saved in:
Bibliographic Details
Title: Technical note: Efficiency of various evaporation barriers for use in automated water samplers for subsequent water isotope analysis.
Authors: Mueller, Christin1,2 (AUTHOR) muller.christin@uqam.ca, Pekarev, Tim Giorgio3,4,5 (AUTHOR), Knoeller, Kay2,6 (AUTHOR)
Source: Hydrology & Earth System Sciences. 2026, Vol. 30 Issue 6, p1801-1812. 12p.
Subject Terms: *Vapor barriers, *Isotopic analysis, *Stable isotopes, *Water sampling, *Isotopic fractionation
Abstract: High temporal and spatial resolution water sampling of stream water or precipitation for subsequent water stable isotope analysis (δ2 H and δ18 O) is commonly conducted with self-made or commercial automated samplers. However, prolonged storage of water samples in open bottles inside autosamplers can lead to isotopic alterations caused by evaporative fractionation and diffusion driven by vapor pressure gradients. In this study, we tested the effectiveness of different evaporation barriers – tube-dip-in, ball valves, and siphons – under controlled laboratory conditions. Experiments were conducted using glass bottles with varying filling levels (50 to 250 mL in 250 mL bottles) and exposure times of up to 52 d. Our results demonstrate that all tested barriers effectively reduce isotopic alterations. Among these, the tube-dip-in emerged as the simplest and most efficient solution, reliably preserving isotopic data even over extended storage durations. We also observed isotopic differences between the water in the tube-dip-in and the main bottle. This phenomenon becomes particularly relevant when sample volumes are very low, as water from the tube-dip-in may influence the overall isotopic composition of the sample. This finding highlights the need for careful consideration of bottle design and sample handling, especially with low water volumes. These findings provide valuable insights for the design of cost-effective, automated water sampling systems for stable isotope applications, emphasizing the importance of evaporation barriers to ensure reliable and accurate isotopic analyses. [ABSTRACT FROM AUTHOR]
Database: Energy & Power Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: enr
DbLabel: Energy & Power Source
An: 192903865
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Technical note: Efficiency of various evaporation barriers for use in automated water samplers for subsequent water isotope analysis.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Mueller%2C+Christin%22">Mueller, Christin</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> muller.christin@uqam.ca</i><br /><searchLink fieldCode="AR" term="%22Pekarev%2C+Tim Giorgio%22">Pekarev, Tim Giorgio</searchLink><relatesTo>3,4,5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Knoeller%2C+Kay%22">Knoeller, Kay</searchLink><relatesTo>2,6</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Hydrology+%26+Earth+System+Sciences%22">Hydrology & Earth System Sciences</searchLink>. 2026, Vol. 30 Issue 6, p1801-1812. 12p.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Vapor+barriers%22">Vapor barriers</searchLink><br />*<searchLink fieldCode="DE" term="%22Isotopic+analysis%22">Isotopic analysis</searchLink><br />*<searchLink fieldCode="DE" term="%22Stable+isotopes%22">Stable isotopes</searchLink><br />*<searchLink fieldCode="DE" term="%22Water+sampling%22">Water sampling</searchLink><br />*<searchLink fieldCode="DE" term="%22Isotopic+fractionation%22">Isotopic fractionation</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: High temporal and spatial resolution water sampling of stream water or precipitation for subsequent water stable isotope analysis (δ2 H and δ18 O) is commonly conducted with self-made or commercial automated samplers. However, prolonged storage of water samples in open bottles inside autosamplers can lead to isotopic alterations caused by evaporative fractionation and diffusion driven by vapor pressure gradients. In this study, we tested the effectiveness of different evaporation barriers – tube-dip-in, ball valves, and siphons – under controlled laboratory conditions. Experiments were conducted using glass bottles with varying filling levels (50 to 250 mL in 250 mL bottles) and exposure times of up to 52 d. Our results demonstrate that all tested barriers effectively reduce isotopic alterations. Among these, the tube-dip-in emerged as the simplest and most efficient solution, reliably preserving isotopic data even over extended storage durations. We also observed isotopic differences between the water in the tube-dip-in and the main bottle. This phenomenon becomes particularly relevant when sample volumes are very low, as water from the tube-dip-in may influence the overall isotopic composition of the sample. This finding highlights the need for careful consideration of bottle design and sample handling, especially with low water volumes. These findings provide valuable insights for the design of cost-effective, automated water sampling systems for stable isotope applications, emphasizing the importance of evaporation barriers to ensure reliable and accurate isotopic analyses. [ABSTRACT FROM AUTHOR]
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=192903865
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.5194/hess-30-1801-2026
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 12
        StartPage: 1801
    Subjects:
      – SubjectFull: Vapor barriers
        Type: general
      – SubjectFull: Isotopic analysis
        Type: general
      – SubjectFull: Stable isotopes
        Type: general
      – SubjectFull: Water sampling
        Type: general
      – SubjectFull: Isotopic fractionation
        Type: general
    Titles:
      – TitleFull: Technical note: Efficiency of various evaporation barriers for use in automated water samplers for subsequent water isotope analysis.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Mueller, Christin
      – PersonEntity:
          Name:
            NameFull: Pekarev, Tim Giorgio
      – PersonEntity:
          Name:
            NameFull: Knoeller, Kay
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 15
              M: 03
              Text: 2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 10275606
          Numbering:
            – Type: volume
              Value: 30
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Hydrology & Earth System Sciences
              Type: main
ResultId 1