Correlation Between Bubble Coverage and Current Density Distribution in a Proton Exchange Membrane Water Electrolyzer.

Saved in:
Bibliographic Details
Title: Correlation Between Bubble Coverage and Current Density Distribution in a Proton Exchange Membrane Water Electrolyzer.
Authors: Chen, Huicui1 (AUTHOR) chenhuicui@tongji.edu.cn, Cheng, Weixuan1,2 (AUTHOR), Zhang, Ruirui1 (AUTHOR), Pei, Pucheng2 (AUTHOR), Ming, Pingwen1 (AUTHOR)
Source: Energies (19961073). Apr2026, Vol. 19 Issue 7, p1754. 20p.
Subject Terms: *Current distribution, *Bubble dynamics, *Electrochemical apparatus, *Ion-permeable membranes, *Electrochemical analysis
Abstract: Gas bubble accumulation and transport play a critical role in the electrochemical performance and reaction uniformity of proton exchange membrane water electrolysis (PEMWE), particularly at high current density. However, the quantitative coupling between bubble coverage and local electrochemical activity remains insufficiently clarified. In this work, a visualization PEMWE combined with a printed circuit board (PCB)-based segmented measurement technique was developed to simultaneously characterize the spatial distributions of bubble coverage and local current density (LCD) under different current densities and operating temperatures. The results showed that both bubble coverage and LCD exhibited pronounced in-plane non-uniformity. The LCD generally displayed lower values in the central region and higher values near the edges, whereas high bubble coverage regions were mainly concentrated in the central and outlet-side areas. As the average current density increased from 0.5 A/cm2 to 2.0 A/cm2, the LCD range expanded from 0.43 to 0.53 A/cm2 to 1.75–2.20 A/cm2, while the local bubble coverage increased from 0.24 to 0.34 to 0.86–0.91. A clear negative spatial correlation between bubble coverage and LCD was identified, and this correlation became stronger with increasing current density. Moreover, the correlation exhibited marked spatial dependence, following the E5 > C3 > E1 > A5 > A1 order. Increasing the operating temperature from 50 to 70 °C alleviated the local heterogeneity, but it did not alter the fundamental coupling trend. These results demonstrate that bubble accumulation is a key factor governing current redistribution and local reaction non-uniformity in PEMWE, and they provide guidance for flow field optimization and high current density operation. [ABSTRACT FROM AUTHOR]
Database: Energy & Power Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: enr
DbLabel: Energy & Power Source
An: 192959158
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Correlation Between Bubble Coverage and Current Density Distribution in a Proton Exchange Membrane Water Electrolyzer.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Chen%2C+Huicui%22">Chen, Huicui</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> chenhuicui@tongji.edu.cn</i><br /><searchLink fieldCode="AR" term="%22Cheng%2C+Weixuan%22">Cheng, Weixuan</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhang%2C+Ruirui%22">Zhang, Ruirui</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Pei%2C+Pucheng%22">Pei, Pucheng</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ming%2C+Pingwen%22">Ming, Pingwen</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Energies+%2819961073%29%22">Energies (19961073)</searchLink>. Apr2026, Vol. 19 Issue 7, p1754. 20p.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Current+distribution%22">Current distribution</searchLink><br />*<searchLink fieldCode="DE" term="%22Bubble+dynamics%22">Bubble dynamics</searchLink><br />*<searchLink fieldCode="DE" term="%22Electrochemical+apparatus%22">Electrochemical apparatus</searchLink><br />*<searchLink fieldCode="DE" term="%22Ion-permeable+membranes%22">Ion-permeable membranes</searchLink><br />*<searchLink fieldCode="DE" term="%22Electrochemical+analysis%22">Electrochemical analysis</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Gas bubble accumulation and transport play a critical role in the electrochemical performance and reaction uniformity of proton exchange membrane water electrolysis (PEMWE), particularly at high current density. However, the quantitative coupling between bubble coverage and local electrochemical activity remains insufficiently clarified. In this work, a visualization PEMWE combined with a printed circuit board (PCB)-based segmented measurement technique was developed to simultaneously characterize the spatial distributions of bubble coverage and local current density (LCD) under different current densities and operating temperatures. The results showed that both bubble coverage and LCD exhibited pronounced in-plane non-uniformity. The LCD generally displayed lower values in the central region and higher values near the edges, whereas high bubble coverage regions were mainly concentrated in the central and outlet-side areas. As the average current density increased from 0.5 A/cm2 to 2.0 A/cm2, the LCD range expanded from 0.43 to 0.53 A/cm2 to 1.75–2.20 A/cm2, while the local bubble coverage increased from 0.24 to 0.34 to 0.86–0.91. A clear negative spatial correlation between bubble coverage and LCD was identified, and this correlation became stronger with increasing current density. Moreover, the correlation exhibited marked spatial dependence, following the E5 > C3 > E1 > A5 > A1 order. Increasing the operating temperature from 50 to 70 °C alleviated the local heterogeneity, but it did not alter the fundamental coupling trend. These results demonstrate that bubble accumulation is a key factor governing current redistribution and local reaction non-uniformity in PEMWE, and they provide guidance for flow field optimization and high current density operation. [ABSTRACT FROM AUTHOR]
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=192959158
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.3390/en19071754
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 20
        StartPage: 1754
    Subjects:
      – SubjectFull: Current distribution
        Type: general
      – SubjectFull: Bubble dynamics
        Type: general
      – SubjectFull: Electrochemical apparatus
        Type: general
      – SubjectFull: Ion-permeable membranes
        Type: general
      – SubjectFull: Electrochemical analysis
        Type: general
    Titles:
      – TitleFull: Correlation Between Bubble Coverage and Current Density Distribution in a Proton Exchange Membrane Water Electrolyzer.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Chen, Huicui
      – PersonEntity:
          Name:
            NameFull: Cheng, Weixuan
      – PersonEntity:
          Name:
            NameFull: Zhang, Ruirui
      – PersonEntity:
          Name:
            NameFull: Pei, Pucheng
      – PersonEntity:
          Name:
            NameFull: Ming, Pingwen
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 19961073
          Numbering:
            – Type: volume
              Value: 19
            – Type: issue
              Value: 7
          Titles:
            – TitleFull: Energies (19961073)
              Type: main
ResultId 1