Unified Stability Metrics for Grid-Support Technologies in a PV-Dominated IEEE 9-Bus Test System.

Saved in:
Bibliographic Details
Title: Unified Stability Metrics for Grid-Support Technologies in a PV-Dominated IEEE 9-Bus Test System.
Authors: Pather, Leeshen1 (AUTHOR) patherl@eskom.co.za, Sarma, Rudiren1 (AUTHOR)
Source: Energies (19961073). Apr2026, Vol. 19 Issue 8, p1906. 51p.
Subject Terms: *Electric power system stability, *Reactive power control, *Battery storage plants, *Frequencies of oscillating systems, *Synchronous capacitors, *Photovoltaic power generation
Abstract: The increase in utility-scale PV generation and the displacement of synchronous machines reduce system strength, reactive power headroom, voltage resilience, and overall power system stability, motivating a robust comparison of various mitigation technologies beyond static load-flow or PV assessments. RMS time-domain simulations are performed for balanced and unbalanced contingencies, and performance is quantified using post-fault voltage dip depth, undervoltage area (V < 0.9 pu.), recovery time to nominal, and RoCoF. These metrics are aggregated into a single weighted composite severity score, which is then normalised to the baseline to form the dynamic voltage resilience index (DVRI) and the Frequency Disturbance Relative Index (FDRI). The results show that the converter-based reactive power support devices deliver the fastest and most controllable post-fault voltage restoration, with the STATCOM achieving the lowest composite penalty and best DVRI under severe fault conditions but the poorest FDRI during PV plant trip/reconnection events. The synchronous condenser (SC) improves post-fault recovery through excitation driven reactive capability and increased short-circuit contribution, but its recovery to nominal voltage levels is slower and can produce negative-sequence current under unbalanced fault conditions whilst producing the smallest frequency disturbance and best FDRI. The SVC provides effective steady-state regulation but becomes less effective during extremely low voltages due to the voltage-dependent reactive power output, and its FDRI remains close to baseline. The BESS-GFM is dependent on the inverter current limits and the control priorities, which influence both voltage recovery and response times, achieving an FDRI scoring second to the SC. These metrics are combined into baseline normalised composite indices (DVRI and FDRI) using explicitly dimensionless sub-metrics (dip magnitude, exposure area, and recovery delay for voltage and deviation magnitude, windowed RoCoF, and exposure for frequency). Equal weights are used as a neutral baseline, and a weight sensitivity study is included to confirm that technology rankings are robust to plausible variations in weighting choice. [ABSTRACT FROM AUTHOR]
Database: Energy & Power Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: enr
DbLabel: Energy & Power Source
An: 193438246
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Unified Stability Metrics for Grid-Support Technologies in a PV-Dominated IEEE 9-Bus Test System.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Pather%2C+Leeshen%22&quot;&gt;Pather, Leeshen&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; patherl@eskom.co.za&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Sarma%2C+Rudiren%22&quot;&gt;Sarma, Rudiren&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Energies+%2819961073%29%22&quot;&gt;Energies (19961073)&lt;/searchLink&gt;. Apr2026, Vol. 19 Issue 8, p1906. 51p.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Electric+power+system+stability%22&quot;&gt;Electric power system stability&lt;/searchLink&gt;&lt;br /&gt;*&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Reactive+power+control%22&quot;&gt;Reactive power control&lt;/searchLink&gt;&lt;br /&gt;*&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Battery+storage+plants%22&quot;&gt;Battery storage plants&lt;/searchLink&gt;&lt;br /&gt;*&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Frequencies+of+oscillating+systems%22&quot;&gt;Frequencies of oscillating systems&lt;/searchLink&gt;&lt;br /&gt;*&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Synchronous+capacitors%22&quot;&gt;Synchronous capacitors&lt;/searchLink&gt;&lt;br /&gt;*&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Photovoltaic+power+generation%22&quot;&gt;Photovoltaic power generation&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The increase in utility-scale PV generation and the displacement of synchronous machines reduce system strength, reactive power headroom, voltage resilience, and overall power system stability, motivating a robust comparison of various mitigation technologies beyond static load-flow or PV assessments. RMS time-domain simulations are performed for balanced and unbalanced contingencies, and performance is quantified using post-fault voltage dip depth, undervoltage area (V &lt; 0.9 pu.), recovery time to nominal, and RoCoF. These metrics are aggregated into a single weighted composite severity score, which is then normalised to the baseline to form the dynamic voltage resilience index (DVRI) and the Frequency Disturbance Relative Index (FDRI). The results show that the converter-based reactive power support devices deliver the fastest and most controllable post-fault voltage restoration, with the STATCOM achieving the lowest composite penalty and best DVRI under severe fault conditions but the poorest FDRI during PV plant trip/reconnection events. The synchronous condenser (SC) improves post-fault recovery through excitation driven reactive capability and increased short-circuit contribution, but its recovery to nominal voltage levels is slower and can produce negative-sequence current under unbalanced fault conditions whilst producing the smallest frequency disturbance and best FDRI. The SVC provides effective steady-state regulation but becomes less effective during extremely low voltages due to the voltage-dependent reactive power output, and its FDRI remains close to baseline. The BESS-GFM is dependent on the inverter current limits and the control priorities, which influence both voltage recovery and response times, achieving an FDRI scoring second to the SC. These metrics are combined into baseline normalised composite indices (DVRI and FDRI) using explicitly dimensionless sub-metrics (dip magnitude, exposure area, and recovery delay for voltage and deviation magnitude, windowed RoCoF, and exposure for frequency). Equal weights are used as a neutral baseline, and a weight sensitivity study is included to confirm that technology rankings are robust to plausible variations in weighting choice. [ABSTRACT FROM AUTHOR]
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=193438246
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.3390/en19081906
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 51
        StartPage: 1906
    Subjects:
      – SubjectFull: Electric power system stability
        Type: general
      – SubjectFull: Reactive power control
        Type: general
      – SubjectFull: Battery storage plants
        Type: general
      – SubjectFull: Frequencies of oscillating systems
        Type: general
      – SubjectFull: Synchronous capacitors
        Type: general
      – SubjectFull: Photovoltaic power generation
        Type: general
    Titles:
      – TitleFull: Unified Stability Metrics for Grid-Support Technologies in a PV-Dominated IEEE 9-Bus Test System.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Pather, Leeshen
      – PersonEntity:
          Name:
            NameFull: Sarma, Rudiren
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 15
              M: 04
              Text: Apr2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 19961073
          Numbering:
            – Type: volume
              Value: 19
            – Type: issue
              Value: 8
          Titles:
            – TitleFull: Energies (19961073)
              Type: main
ResultId 1