A Simplified Temperature Field Calculation Model for Oil-Immersed Transformers Based on the FVM-POD Field–Circuit Coupling Method.

Saved in:
Bibliographic Details
Title: A Simplified Temperature Field Calculation Model for Oil-Immersed Transformers Based on the FVM-POD Field–Circuit Coupling Method.
Authors: Yuan, Yanan1,2 (AUTHOR), Yang, Hao1,2 (AUTHOR) yanghao@cqu.edu.cn, Wang, Shijun1 (AUTHOR), Yue, Linhong1,2 (AUTHOR)
Source: Energies (19961073). Apr2026, Vol. 19 Issue 8, p2003. 23p.
Subject Terms: *Finite volume method, *Proper orthogonal decomposition, *Temperature distribution, *Insulating oils, *Digital twin, *Thermal hydraulics
Abstract: In the context of new-type power system construction, digital twin has become the core technology for power transformers, supporting their full-life cycle intelligent operation and maintenance. The real-time, high-precision calculation of the internal temperature field serves as the core supporting element for realizing the real-time mapping between the physical transformer entity and its virtual twin. Aiming at the inherent defects of traditional temperature rise calculation methods, such as insufficient accuracy and an excessively long computation time, this paper proposes a simplified calculation model for the transformer temperature field. In this model, the transformer oil tank is simplified into a two-dimensional axisymmetric thermal–fluid coupled field model solved by the finite volume method (FVM). The Proper Orthogonal Decomposition (POD) technique is adopted to perform order reduction on the matrices involved in the governing equations, so as to reduce the computational degrees of freedom. Meanwhile, the radiator is equivalent to a one-dimensional thermal circuit model, and the field–circuit coupled solution is achieved through bidirectional data mapping. Temperature field calculation is carried out for a 220 kV oil-immersed transformer based on the proposed model. The results show that the average relative error between the calculated results and the experimental data is around 0.86%, while the computation time is merely 0.04% of that of the traditional three-dimensional full-scale model. Furthermore, taking the real-time overload capacity evaluation of the transformer as a case, it is verified that the proposed model can successfully support the requirements of practical engineering applications. [ABSTRACT FROM AUTHOR]
Database: Energy & Power Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: enr
DbLabel: Energy & Power Source
An: 193438343
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: A Simplified Temperature Field Calculation Model for Oil-Immersed Transformers Based on the FVM-POD Field–Circuit Coupling Method.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Yuan%2C+Yanan%22">Yuan, Yanan</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Yang%2C+Hao%22">Yang, Hao</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> yanghao@cqu.edu.cn</i><br /><searchLink fieldCode="AR" term="%22Wang%2C+Shijun%22">Wang, Shijun</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Yue%2C+Linhong%22">Yue, Linhong</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Energies+%2819961073%29%22">Energies (19961073)</searchLink>. Apr2026, Vol. 19 Issue 8, p2003. 23p.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Finite+volume+method%22">Finite volume method</searchLink><br />*<searchLink fieldCode="DE" term="%22Proper+orthogonal+decomposition%22">Proper orthogonal decomposition</searchLink><br />*<searchLink fieldCode="DE" term="%22Temperature+distribution%22">Temperature distribution</searchLink><br />*<searchLink fieldCode="DE" term="%22Insulating+oils%22">Insulating oils</searchLink><br />*<searchLink fieldCode="DE" term="%22Digital+twin%22">Digital twin</searchLink><br />*<searchLink fieldCode="DE" term="%22Thermal+hydraulics%22">Thermal hydraulics</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: In the context of new-type power system construction, digital twin has become the core technology for power transformers, supporting their full-life cycle intelligent operation and maintenance. The real-time, high-precision calculation of the internal temperature field serves as the core supporting element for realizing the real-time mapping between the physical transformer entity and its virtual twin. Aiming at the inherent defects of traditional temperature rise calculation methods, such as insufficient accuracy and an excessively long computation time, this paper proposes a simplified calculation model for the transformer temperature field. In this model, the transformer oil tank is simplified into a two-dimensional axisymmetric thermal–fluid coupled field model solved by the finite volume method (FVM). The Proper Orthogonal Decomposition (POD) technique is adopted to perform order reduction on the matrices involved in the governing equations, so as to reduce the computational degrees of freedom. Meanwhile, the radiator is equivalent to a one-dimensional thermal circuit model, and the field–circuit coupled solution is achieved through bidirectional data mapping. Temperature field calculation is carried out for a 220 kV oil-immersed transformer based on the proposed model. The results show that the average relative error between the calculated results and the experimental data is around 0.86%, while the computation time is merely 0.04% of that of the traditional three-dimensional full-scale model. Furthermore, taking the real-time overload capacity evaluation of the transformer as a case, it is verified that the proposed model can successfully support the requirements of practical engineering applications. [ABSTRACT FROM AUTHOR]
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=193438343
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.3390/en19082003
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 23
        StartPage: 2003
    Subjects:
      – SubjectFull: Finite volume method
        Type: general
      – SubjectFull: Proper orthogonal decomposition
        Type: general
      – SubjectFull: Temperature distribution
        Type: general
      – SubjectFull: Insulating oils
        Type: general
      – SubjectFull: Digital twin
        Type: general
      – SubjectFull: Thermal hydraulics
        Type: general
    Titles:
      – TitleFull: A Simplified Temperature Field Calculation Model for Oil-Immersed Transformers Based on the FVM-POD Field–Circuit Coupling Method.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Yuan, Yanan
      – PersonEntity:
          Name:
            NameFull: Yang, Hao
      – PersonEntity:
          Name:
            NameFull: Wang, Shijun
      – PersonEntity:
          Name:
            NameFull: Yue, Linhong
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 15
              M: 04
              Text: Apr2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 19961073
          Numbering:
            – Type: volume
              Value: 19
            – Type: issue
              Value: 8
          Titles:
            – TitleFull: Energies (19961073)
              Type: main
ResultId 1