A Simplified Temperature Field Calculation Model for Oil-Immersed Transformers Based on the FVM-POD Field–Circuit Coupling Method.
Saved in:
| Title: | A Simplified Temperature Field Calculation Model for Oil-Immersed Transformers Based on the FVM-POD Field–Circuit Coupling Method. |
|---|---|
| Authors: | Yuan, Yanan1,2 (AUTHOR), Yang, Hao1,2 (AUTHOR) yanghao@cqu.edu.cn, Wang, Shijun1 (AUTHOR), Yue, Linhong1,2 (AUTHOR) |
| Source: | Energies (19961073). Apr2026, Vol. 19 Issue 8, p2003. 23p. |
| Subject Terms: | *Finite volume method, *Proper orthogonal decomposition, *Temperature distribution, *Insulating oils, *Digital twin, *Thermal hydraulics |
| Abstract: | In the context of new-type power system construction, digital twin has become the core technology for power transformers, supporting their full-life cycle intelligent operation and maintenance. The real-time, high-precision calculation of the internal temperature field serves as the core supporting element for realizing the real-time mapping between the physical transformer entity and its virtual twin. Aiming at the inherent defects of traditional temperature rise calculation methods, such as insufficient accuracy and an excessively long computation time, this paper proposes a simplified calculation model for the transformer temperature field. In this model, the transformer oil tank is simplified into a two-dimensional axisymmetric thermal–fluid coupled field model solved by the finite volume method (FVM). The Proper Orthogonal Decomposition (POD) technique is adopted to perform order reduction on the matrices involved in the governing equations, so as to reduce the computational degrees of freedom. Meanwhile, the radiator is equivalent to a one-dimensional thermal circuit model, and the field–circuit coupled solution is achieved through bidirectional data mapping. Temperature field calculation is carried out for a 220 kV oil-immersed transformer based on the proposed model. The results show that the average relative error between the calculated results and the experimental data is around 0.86%, while the computation time is merely 0.04% of that of the traditional three-dimensional full-scale model. Furthermore, taking the real-time overload capacity evaluation of the transformer as a case, it is verified that the proposed model can successfully support the requirements of practical engineering applications. [ABSTRACT FROM AUTHOR] |
| Database: | Energy & Power Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: enr DbLabel: Energy & Power Source An: 193438343 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: A Simplified Temperature Field Calculation Model for Oil-Immersed Transformers Based on the FVM-POD Field–Circuit Coupling Method. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Yuan%2C+Yanan%22">Yuan, Yanan</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Yang%2C+Hao%22">Yang, Hao</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> yanghao@cqu.edu.cn</i><br /><searchLink fieldCode="AR" term="%22Wang%2C+Shijun%22">Wang, Shijun</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Yue%2C+Linhong%22">Yue, Linhong</searchLink><relatesTo>1,2</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Energies+%2819961073%29%22">Energies (19961073)</searchLink>. Apr2026, Vol. 19 Issue 8, p2003. 23p. – Name: Subject Label: Subject Terms Group: Su Data: *<searchLink fieldCode="DE" term="%22Finite+volume+method%22">Finite volume method</searchLink><br />*<searchLink fieldCode="DE" term="%22Proper+orthogonal+decomposition%22">Proper orthogonal decomposition</searchLink><br />*<searchLink fieldCode="DE" term="%22Temperature+distribution%22">Temperature distribution</searchLink><br />*<searchLink fieldCode="DE" term="%22Insulating+oils%22">Insulating oils</searchLink><br />*<searchLink fieldCode="DE" term="%22Digital+twin%22">Digital twin</searchLink><br />*<searchLink fieldCode="DE" term="%22Thermal+hydraulics%22">Thermal hydraulics</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: In the context of new-type power system construction, digital twin has become the core technology for power transformers, supporting their full-life cycle intelligent operation and maintenance. The real-time, high-precision calculation of the internal temperature field serves as the core supporting element for realizing the real-time mapping between the physical transformer entity and its virtual twin. Aiming at the inherent defects of traditional temperature rise calculation methods, such as insufficient accuracy and an excessively long computation time, this paper proposes a simplified calculation model for the transformer temperature field. In this model, the transformer oil tank is simplified into a two-dimensional axisymmetric thermal–fluid coupled field model solved by the finite volume method (FVM). The Proper Orthogonal Decomposition (POD) technique is adopted to perform order reduction on the matrices involved in the governing equations, so as to reduce the computational degrees of freedom. Meanwhile, the radiator is equivalent to a one-dimensional thermal circuit model, and the field–circuit coupled solution is achieved through bidirectional data mapping. Temperature field calculation is carried out for a 220 kV oil-immersed transformer based on the proposed model. The results show that the average relative error between the calculated results and the experimental data is around 0.86%, while the computation time is merely 0.04% of that of the traditional three-dimensional full-scale model. Furthermore, taking the real-time overload capacity evaluation of the transformer as a case, it is verified that the proposed model can successfully support the requirements of practical engineering applications. [ABSTRACT FROM AUTHOR] |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=193438343 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.3390/en19082003 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 23 StartPage: 2003 Subjects: – SubjectFull: Finite volume method Type: general – SubjectFull: Proper orthogonal decomposition Type: general – SubjectFull: Temperature distribution Type: general – SubjectFull: Insulating oils Type: general – SubjectFull: Digital twin Type: general – SubjectFull: Thermal hydraulics Type: general Titles: – TitleFull: A Simplified Temperature Field Calculation Model for Oil-Immersed Transformers Based on the FVM-POD Field–Circuit Coupling Method. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Yuan, Yanan – PersonEntity: Name: NameFull: Yang, Hao – PersonEntity: Name: NameFull: Wang, Shijun – PersonEntity: Name: NameFull: Yue, Linhong IsPartOfRelationships: – BibEntity: Dates: – D: 15 M: 04 Text: Apr2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 19961073 Numbering: – Type: volume Value: 19 – Type: issue Value: 8 Titles: – TitleFull: Energies (19961073) Type: main |
| ResultId | 1 |