The Impact of 'Thermo-Protective' Paints on the Thermal Insulation of External Walls.
Saved in:
| Title: | The Impact of 'Thermo-Protective' Paints on the Thermal Insulation of External Walls. |
|---|---|
| Authors: | Gawełek, Mateusz1 (AUTHOR), Norvaisiene, Rosita2 (AUTHOR), Krause, Paweł1,3 (AUTHOR) pawel.krause@polsl.pl, Belok, Janusz1 (AUTHOR), Wilk-Słomka, Beata1,2 (AUTHOR), Marchacz, Michał1,3 (AUTHOR), Sitek, Michał3 (AUTHOR) |
| Source: | Energies (19961073). May2026, Vol. 19 Issue 10, p2362. 26p. |
| Subject Terms: | *Heat transfer coefficient, *Building envelopes, *Surface temperature, *Thermal resistance, *Thermography, *Solar radiation, *Thermal insulation |
| Abstract: | This article focuses on aspects related to the physical and thermal parameters of so-called thermal-insulating paints. These materials and systems are used in two different situations: first, as agents reducing surface temperature due to solar radiation, and second, as so-called "thermal-insulating" coatings. The paper focuses on the second aspect of the applications described by the manufacturers and presents the results of the author's laboratory tests (using an insulated heating box with two different heat sources) and field tests (in situ) on a building façade. The research methodology focuses on contact and thermal imaging measurements to assess the effectiveness and properties of reflective thermal-insulating paints, as well as analyzing their impact on the surface temperature and heat transfer coefficient of building envelopes. The conducted research showed that the use of reflective thermal-insulating paints does not significantly improve the thermal insulation of building envelopes. Measurements of the heat transfer coefficient showed a reduction of 1–7% compared to the reference wall tested. In situ measurements using temperature sensors and thermographic studies confirmed the insignificant impact of reflective thermal insulation paints on the thermal protection of external walls. [ABSTRACT FROM AUTHOR] |
| Database: | Energy & Power Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: enr DbLabel: Energy & Power Source An: 194141477 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: The Impact of 'Thermo-Protective' Paints on the Thermal Insulation of External Walls. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Gawełek%2C+Mateusz%22">Gawełek, Mateusz</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Norvaisiene%2C+Rosita%22">Norvaisiene, Rosita</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Krause%2C+Paweł%22">Krause, Paweł</searchLink><relatesTo>1,3</relatesTo> (AUTHOR)<i> pawel.krause@polsl.pl</i><br /><searchLink fieldCode="AR" term="%22Belok%2C+Janusz%22">Belok, Janusz</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wilk-Słomka%2C+Beata%22">Wilk-Słomka, Beata</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Marchacz%2C+Michał%22">Marchacz, Michał</searchLink><relatesTo>1,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sitek%2C+Michał%22">Sitek, Michał</searchLink><relatesTo>3</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Energies+%2819961073%29%22">Energies (19961073)</searchLink>. May2026, Vol. 19 Issue 10, p2362. 26p. – Name: Subject Label: Subject Terms Group: Su Data: *<searchLink fieldCode="DE" term="%22Heat+transfer+coefficient%22">Heat transfer coefficient</searchLink><br />*<searchLink fieldCode="DE" term="%22Building+envelopes%22">Building envelopes</searchLink><br />*<searchLink fieldCode="DE" term="%22Surface+temperature%22">Surface temperature</searchLink><br />*<searchLink fieldCode="DE" term="%22Thermal+resistance%22">Thermal resistance</searchLink><br />*<searchLink fieldCode="DE" term="%22Thermography%22">Thermography</searchLink><br />*<searchLink fieldCode="DE" term="%22Solar+radiation%22">Solar radiation</searchLink><br />*<searchLink fieldCode="DE" term="%22Thermal+insulation%22">Thermal insulation</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: This article focuses on aspects related to the physical and thermal parameters of so-called thermal-insulating paints. These materials and systems are used in two different situations: first, as agents reducing surface temperature due to solar radiation, and second, as so-called "thermal-insulating" coatings. The paper focuses on the second aspect of the applications described by the manufacturers and presents the results of the author's laboratory tests (using an insulated heating box with two different heat sources) and field tests (in situ) on a building façade. The research methodology focuses on contact and thermal imaging measurements to assess the effectiveness and properties of reflective thermal-insulating paints, as well as analyzing their impact on the surface temperature and heat transfer coefficient of building envelopes. The conducted research showed that the use of reflective thermal-insulating paints does not significantly improve the thermal insulation of building envelopes. Measurements of the heat transfer coefficient showed a reduction of 1–7% compared to the reference wall tested. In situ measurements using temperature sensors and thermographic studies confirmed the insignificant impact of reflective thermal insulation paints on the thermal protection of external walls. [ABSTRACT FROM AUTHOR] |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=194141477 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.3390/en19102362 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 26 StartPage: 2362 Subjects: – SubjectFull: Heat transfer coefficient Type: general – SubjectFull: Building envelopes Type: general – SubjectFull: Surface temperature Type: general – SubjectFull: Thermal resistance Type: general – SubjectFull: Thermography Type: general – SubjectFull: Solar radiation Type: general – SubjectFull: Thermal insulation Type: general Titles: – TitleFull: The Impact of 'Thermo-Protective' Paints on the Thermal Insulation of External Walls. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Gawełek, Mateusz – PersonEntity: Name: NameFull: Norvaisiene, Rosita – PersonEntity: Name: NameFull: Krause, Paweł – PersonEntity: Name: NameFull: Belok, Janusz – PersonEntity: Name: NameFull: Wilk-Słomka, Beata – PersonEntity: Name: NameFull: Marchacz, Michał – PersonEntity: Name: NameFull: Sitek, Michał IsPartOfRelationships: – BibEntity: Dates: – D: 15 M: 05 Text: May2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 19961073 Numbering: – Type: volume Value: 19 – Type: issue Value: 10 Titles: – TitleFull: Energies (19961073) Type: main |
| ResultId | 1 |