Power Quality Disturbances and Operating Regimes as Determinants of Reliability and Technical Condition of Industrial Electrical Equipment: A Comprehensive Review.
Saved in:
| Title: | Power Quality Disturbances and Operating Regimes as Determinants of Reliability and Technical Condition of Industrial Electrical Equipment: A Comprehensive Review. |
|---|---|
| Authors: | Nazarychev, Alexander1 (AUTHOR), Tereshchenko, Ilia1 (AUTHOR) s245027@stud.spmi.ru |
| Source: | Energies (19961073). Jun2026, Vol. 19 Issue 11, p2685. 47p. |
| Subject Terms: | *Power quality disturbances, *Reliability in engineering, *Condition-based maintenance, *Electric transients, *Harmonic distortion (Physics), *Industrial equipment |
| Abstract: | The review presents a comprehensive review of the influence of power quality indicators and operating conditions at industrial enterprises on the technical condition and reliability of electrical equipment. Harmonic distortion, voltage fluctuations and sags, load surges, overvoltages, and voltage unbalance are considered factors that increase thermal, electrical, and mechanical stresses in transformers, induction motors, cable lines, and overhead power lines. It is shown that these disturbances can increase RMS currents, additional losses, hot-spot temperature, vibration, and insulation aging rate, reducing equipment service life and increasing failure probability. The review links power quality disturbances with thermal aging models, remaining useful life assessment, and probabilistic reliability models, including the Weibull distribution. It is established that a correct remaining service life assessment requires considering not only individual disturbances but also the combined influence of voltage and current quality, load conditions, ambient temperature, and humidity. Particular attention is paid to modern monitoring and forecasting technologies, including IoT systems, multi-agent models, machine learning, and predictive diagnostics. These technologies enable the transition from scheduled maintenance to continuous multiparameter monitoring. A structure for quantitative risk assessment and practical recommendations for predictive maintenance of industrial electrical equipment are proposed. [ABSTRACT FROM AUTHOR] |
| Database: | Energy & Power Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: enr DbLabel: Energy & Power Source An: 194588073 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Power Quality Disturbances and Operating Regimes as Determinants of Reliability and Technical Condition of Industrial Electrical Equipment: A Comprehensive Review. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Nazarychev%2C+Alexander%22">Nazarychev, Alexander</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Tereshchenko%2C+Ilia%22">Tereshchenko, Ilia</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> s245027@stud.spmi.ru</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Energies+%2819961073%29%22">Energies (19961073)</searchLink>. Jun2026, Vol. 19 Issue 11, p2685. 47p. – Name: Subject Label: Subject Terms Group: Su Data: *<searchLink fieldCode="DE" term="%22Power+quality+disturbances%22">Power quality disturbances</searchLink><br />*<searchLink fieldCode="DE" term="%22Reliability+in+engineering%22">Reliability in engineering</searchLink><br />*<searchLink fieldCode="DE" term="%22Condition-based+maintenance%22">Condition-based maintenance</searchLink><br />*<searchLink fieldCode="DE" term="%22Electric+transients%22">Electric transients</searchLink><br />*<searchLink fieldCode="DE" term="%22Harmonic+distortion+%28Physics%29%22">Harmonic distortion (Physics)</searchLink><br />*<searchLink fieldCode="DE" term="%22Industrial+equipment%22">Industrial equipment</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: The review presents a comprehensive review of the influence of power quality indicators and operating conditions at industrial enterprises on the technical condition and reliability of electrical equipment. Harmonic distortion, voltage fluctuations and sags, load surges, overvoltages, and voltage unbalance are considered factors that increase thermal, electrical, and mechanical stresses in transformers, induction motors, cable lines, and overhead power lines. It is shown that these disturbances can increase RMS currents, additional losses, hot-spot temperature, vibration, and insulation aging rate, reducing equipment service life and increasing failure probability. The review links power quality disturbances with thermal aging models, remaining useful life assessment, and probabilistic reliability models, including the Weibull distribution. It is established that a correct remaining service life assessment requires considering not only individual disturbances but also the combined influence of voltage and current quality, load conditions, ambient temperature, and humidity. Particular attention is paid to modern monitoring and forecasting technologies, including IoT systems, multi-agent models, machine learning, and predictive diagnostics. These technologies enable the transition from scheduled maintenance to continuous multiparameter monitoring. A structure for quantitative risk assessment and practical recommendations for predictive maintenance of industrial electrical equipment are proposed. [ABSTRACT FROM AUTHOR] |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=194588073 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.3390/en19112685 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 47 StartPage: 2685 Subjects: – SubjectFull: Power quality disturbances Type: general – SubjectFull: Reliability in engineering Type: general – SubjectFull: Condition-based maintenance Type: general – SubjectFull: Electric transients Type: general – SubjectFull: Harmonic distortion (Physics) Type: general – SubjectFull: Industrial equipment Type: general Titles: – TitleFull: Power Quality Disturbances and Operating Regimes as Determinants of Reliability and Technical Condition of Industrial Electrical Equipment: A Comprehensive Review. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Nazarychev, Alexander – PersonEntity: Name: NameFull: Tereshchenko, Ilia IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 06 Text: Jun2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 19961073 Numbering: – Type: volume Value: 19 – Type: issue Value: 11 Titles: – TitleFull: Energies (19961073) Type: main |
| ResultId | 1 |