Abstract: Air structures have developed through a number of significant stages: military applications, conventional standard air structures (the "bubbles"), exhibition structures, and permanent building applications. With no other type of structure is it possible to obtain clear, widespan coverage of almost unlimited areas, additional ceiling clearance for recreational activities at essentially no cost, translucency to permit uniform daylight, lighting through the entire roof system, and transportability or relocatability. Therefore, it is necessary to take into account the many features that are unique to the air-supported structure alone in evaluating competitive designs. If an optimum design for lowest cost is to be provided, and if the structures are to be successful, they must be of quality design; the design must fully coordinate methods of fabrication, handling, and shipment; and the installation procedures should be fully explored as part of the design with a fabricator experienced in working with large fabric structures. (Author/MLF)
Notes: Speech given before Building Research Institute National Technical Conference (Columbia, Maryland, May 22-24, 1973)
Journal Code: RIEMAR1974
Entry Date: 1974
Accession Number: ED083700
Database: ERIC
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://eric.ed.gov/contentdelivery/servlet/ERICServlet?accno=ED083700
    Name: ERIC Full Text
    Category: fullText
    Text: Full Text from ERIC
Header DbId: eric
DbLabel: ERIC
An: ED083700
AccessLevel: 3
PubTypeId: unknown
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: A New Generation of Air Structures.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Bird%2C+Walter+W%2E%22">Bird, Walter W.</searchLink>
– Name: PeerReviewed
  Label: Peer Reviewed
  Group: SrcInfo
  Data: N
– Name: Pages
  Label: Page Count
  Group: Src
  Data: 8
– Name: DatePubCY
  Label: Publication Date
  Group: Date
  Data: 1973
– Name: Subject
  Label: Descriptors
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Air+Structures%22">Air Structures</searchLink><br /><searchLink fieldCode="DE" term="%22Architectural+Programing%22">Architectural Programing</searchLink><br /><searchLink fieldCode="DE" term="%22Building+Design%22">Building Design</searchLink><br /><searchLink fieldCode="DE" term="%22Construction+Costs%22">Construction Costs</searchLink><br /><searchLink fieldCode="DE" term="%22Construction+Materials%22">Construction Materials</searchLink><br /><searchLink fieldCode="DE" term="%22Design+Requirements%22">Design Requirements</searchLink><br /><searchLink fieldCode="DE" term="%22Facility+Guidelines%22">Facility Guidelines</searchLink><br /><searchLink fieldCode="DE" term="%22Facility+Planning%22">Facility Planning</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Air structures have developed through a number of significant stages: military applications, conventional standard air structures (the "bubbles"), exhibition structures, and permanent building applications. With no other type of structure is it possible to obtain clear, widespan coverage of almost unlimited areas, additional ceiling clearance for recreational activities at essentially no cost, translucency to permit uniform daylight, lighting through the entire roof system, and transportability or relocatability. Therefore, it is necessary to take into account the many features that are unique to the air-supported structure alone in evaluating competitive designs. If an optimum design for lowest cost is to be provided, and if the structures are to be successful, they must be of quality design; the design must fully coordinate methods of fabrication, handling, and shipment; and the installation procedures should be fully explored as part of the design with a fabricator experienced in working with large fabric structures. (Author/MLF)
– Name: Note
  Label: Notes
  Group: Note
  Data: Speech given before Building Research Institute National Technical Conference (Columbia, Maryland, May 22-24, 1973)
– Name: CodeSource
  Label: Journal Code
  Group: SrcInfo
  Data: <searchLink fieldCode="JC" term="%22RIEMAR1974%22">RIEMAR1974</searchLink>
– Name: DateEntry
  Label: Entry Date
  Group: Date
  Data: 1974
– Name: AN
  Label: Accession Number
  Group: ID
  Data: ED083700
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=eric&AN=ED083700
RecordInfo BibRecord:
  BibEntity:
    PhysicalDescription:
      Pagination:
        PageCount: 8
    Subjects:
      – SubjectFull: Air Structures
        Type: general
      – SubjectFull: Architectural Programing
        Type: general
      – SubjectFull: Building Design
        Type: general
      – SubjectFull: Construction Costs
        Type: general
      – SubjectFull: Construction Materials
        Type: general
      – SubjectFull: Design Requirements
        Type: general
      – SubjectFull: Facility Guidelines
        Type: general
      – SubjectFull: Facility Planning
        Type: general
    Titles:
      – TitleFull: A New Generation of Air Structures.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Bird, Walter W.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Type: published
              Y: 1973
ResultId 1