Comparación de dos Sistemas de Captura de Movimiento por medio de las Trayectorias Articulares de Marcha.

Saved in:
Bibliographic Details
Title: Comparación de dos Sistemas de Captura de Movimiento por medio de las Trayectorias Articulares de Marcha.
Authors: Bravo M., D. A.1 dibravo@unicauca.edu.co, Rengifo R., C. F.2, Agredo R., W.3
Source: Revista Mexicana de Ingeniería Biomédica. May-Ago2016, Vol. 37 Issue 2, p149-160. 12p.
Abstract (English): Currently, the most common methods for proper capture of human movement in three dimensions require a laboratory environment and setting markers, accessories or sensors to the body segments. However, the high cost of this equipment is a limiting factor in diverse environments. Motion capture systems such as Microsoft Kinect™present an alternative approach to motion capture technology. In this paper, two motion capture systems are compared by means of joint trajectories and anthropometric measurements of a person in a normal gait cycle. The first is accurate trading system that uses markers (Vicon™), and the second is Microsoft Kinect™ camera. Both systems were evaluated in order to compare the geometric difference and the RMS error between the joint human walking paths obtained for each of the systems. The results show a greater variance in anthropometric measures and joint trajectories for Kinect, although this system is inexpensive and easy to use and install, cannot be used for precise kinematic analysis of human walking. [ABSTRACT FROM AUTHOR]
Abstract (Spanish): En la actualidad, los métodos más comunes para una adecuada captura del movimiento humano en tres dimensiones requieren de un entorno de laboratorio y la fijación de marcadores, accesorios o sensores a los segmentos corporales. Sin embargo, el alto costo de estos equipos es un factor limitante en diversos entornos de trabajo. Sistemas de captura de movimiento como Microsoft Kinect ™presentan un enfoque alternativo a la tecnología de captura de movimiento. En este trabajo se comparan dos sistemas de captura de movimiento por medio de las trayectorias articulares y las medidas antropométricas de una persona en un ciclo de marcha normal. El primero de ellos, es un sistema comercial de precisión que utiliza marcadores (Vicon ™) y el segundo, es la cámara Microsoft Kinect™. Ambos sistemas se evaluaron con el propósito de comparar la diferencia geométrica y el error RMS entre las trayectorias articulares de la marcha humana obtenidas por cada uno de los sistemas. Los resultados muestran una varianza mayor en las medidas antropométricas y trayectorias articulares para el Kinect, aunque este sistema es de bajo costo y de fácil uso e instalación, no puede ser utilizado para un análisis preciso de la cinemática de la marcha humana. [ABSTRACT FROM AUTHOR]
Copyright of Revista Mexicana de Ingeniería Biomédica is the property of Sociedad Mexicana de Ingenieria Biomedica, A.C. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: MedicLatina
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: lth
DbLabel: MedicLatina
An: 126949765
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Comparación de dos Sistemas de Captura de Movimiento por medio de las Trayectorias Articulares de Marcha.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Bravo+M%2E%2C+D%2E+A%2E%22">Bravo M., D. A.</searchLink><relatesTo>1</relatesTo><i> dibravo@unicauca.edu.co</i><br /><searchLink fieldCode="AR" term="%22Rengifo+R%2E%2C+C%2E+F%2E%22">Rengifo R., C. F.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Agredo+R%2E%2C+W%2E%22">Agredo R., W.</searchLink><relatesTo>3</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Revista+Mexicana+de+Ingeniería+Biomédica%22">Revista Mexicana de Ingeniería Biomédica</searchLink>. May-Ago2016, Vol. 37 Issue 2, p149-160. 12p.
– Name: Abstract
  Label: Abstract (English)
  Group: Ab
  Data: Currently, the most common methods for proper capture of human movement in three dimensions require a laboratory environment and setting markers, accessories or sensors to the body segments. However, the high cost of this equipment is a limiting factor in diverse environments. Motion capture systems such as Microsoft Kinect™present an alternative approach to motion capture technology. In this paper, two motion capture systems are compared by means of joint trajectories and anthropometric measurements of a person in a normal gait cycle. The first is accurate trading system that uses markers (Vicon™), and the second is Microsoft Kinect™ camera. Both systems were evaluated in order to compare the geometric difference and the RMS error between the joint human walking paths obtained for each of the systems. The results show a greater variance in anthropometric measures and joint trajectories for Kinect, although this system is inexpensive and easy to use and install, cannot be used for precise kinematic analysis of human walking. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label: Abstract (Spanish)
  Group: Ab
  Data: En la actualidad, los métodos más comunes para una adecuada captura del movimiento humano en tres dimensiones requieren de un entorno de laboratorio y la fijación de marcadores, accesorios o sensores a los segmentos corporales. Sin embargo, el alto costo de estos equipos es un factor limitante en diversos entornos de trabajo. Sistemas de captura de movimiento como Microsoft Kinect ™presentan un enfoque alternativo a la tecnología de captura de movimiento. En este trabajo se comparan dos sistemas de captura de movimiento por medio de las trayectorias articulares y las medidas antropométricas de una persona en un ciclo de marcha normal. El primero de ellos, es un sistema comercial de precisión que utiliza marcadores (Vicon ™) y el segundo, es la cámara Microsoft Kinect™. Ambos sistemas se evaluaron con el propósito de comparar la diferencia geométrica y el error RMS entre las trayectorias articulares de la marcha humana obtenidas por cada uno de los sistemas. Los resultados muestran una varianza mayor en las medidas antropométricas y trayectorias articulares para el Kinect, aunque este sistema es de bajo costo y de fácil uso e instalación, no puede ser utilizado para un análisis preciso de la cinemática de la marcha humana. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Revista Mexicana de Ingeniería Biomédica is the property of Sociedad Mexicana de Ingenieria Biomedica, A.C. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=126949765
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.17488/RMIB.37.2.2
    Languages:
      – Code: spa
        Text: Spanish
    PhysicalDescription:
      Pagination:
        PageCount: 12
        StartPage: 149
    Titles:
      – TitleFull: Comparación de dos Sistemas de Captura de Movimiento por medio de las Trayectorias Articulares de Marcha.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Bravo M., D. A.
      – PersonEntity:
          Name:
            NameFull: Rengifo R., C. F.
      – PersonEntity:
          Name:
            NameFull: Agredo R., W.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Text: May-Ago2016
              Type: published
              Y: 2016
          Identifiers:
            – Type: issn-print
              Value: 01889532
          Numbering:
            – Type: volume
              Value: 37
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Revista Mexicana de Ingeniería Biomédica
              Type: main
ResultId 1