Cistatina C vs. marcadores convencionales de función renal: una actualización.

Saved in:
Bibliographic Details
Title: Cistatina C vs. marcadores convencionales de función renal: una actualización.
Alternate Title: Cystatin C vs conventional markers of renal function: an update.
Authors: López, Laura Ramírez1 lauramirez@uniboyaca.edu.co, Suárez, Laura Albarracín2 lxalbarracin@uniboyaca.edu.co, Zaraza, Daniela Castillo2 dancastillo@uniboyaca.edu.co, Sánchez, Julio Bueno3 julio.bueno@udea.edu.co, Becerra, Astrid Aguilera1 amaguilera@uniboyaca.edu.co
Source: Salud Uninorte. Ene-Apr2019, Vol. 35 Issue 1, p93-115. 23p.
Subjects: BLOOD urea nitrogen, GLOMERULAR filtration rate, CHRONIC kidney failure, DIAGNOSIS, NEEDS assessment
Abstract (English): Objective: To provide current information about the progress of the last ten years reported to improve the diagnosis of kidney disease with markers such as cystatin C, with other usual analytes used in clinical practice. Materials and methods: A search for original and review articles in english and spanish in the last ten years was carried out in the following databases: MedLine, Library Plus, ProQuest, NCBI and ScienceDirect. Results: For the evaluation of renal function markers are used such as creatinine and blood urea nitrogen. However, these tests are sometimes determined to different sources of biological variability, which is why the need to identify other markers that detect kidney damage early, and that is not influenced by pacific-dependent factors such as Cystatin C, a molecular protein of low molecular weight proposed as a marker of renal function more accurate, specific and sensitive than creatinine in modifying the glomerular filtration rate. Conclusion: Cystatin C meets with characteristics that make it a more useful biomarker in the determination of renal injury, since it shows greater diagnostic utility than serum creatinine to detect early renal damage, however, it is not used as a routine test in the diagnosis of renal pathologies due to its high cost when assembling in the clinical laboratory. [ABSTRACT FROM AUTHOR]
Abstract (Spanish): Objetivo: Esta revisión busca proporcionar información actual de los avances de los últimos diez años reportados para mejorar el diagnóstico de enfermedad renal con marcadores como la cistatina C, en comparación con otros analitos convencionales utilizados en la práctica clínica. Materiales y métodos: Se llevó a cabo una búsqueda de artículos originales y de revisión en idioma inglés y español de los últimos diez años en las siguientes bases de datos: MedLine, Library Plus, ProQuest, NCBI y ScienceDirect. Resultados: Para la evaluación de la función renal se usan marcadores convencionales como la creatinina y el nitrógeno ureico en sangre. Sin embargo, estas pruebas están sometidas a diferentes fuentes de variabilidad biológica, razón por la cual se ve la necesidad de identificar otros marcadores que permitan detectar de forma precoz la lesión renal, y que no se vean influenciados por factores dependientes del paciente como la cistatina C, una proteína de bajo peso molecular propuesta como un marcador de función renal más exacto, específico y sensible que la creatinina en la estimación de la tasa de filtración glomerular. Conclusión: Se considera que la cistatina C cumple con características que la hacen un biomarcador más útil en la determinación de lesión renal, ya que muestra mayor utilidad diagnóstica que la creatinina sérica para detectar daño renal temprano, sin embargo, no se utiliza como prueba rutinaria en el diagnóstico de patologías renales por su alto costo al momento de realizar un montaje en el laboratorio clínico. [ABSTRACT FROM AUTHOR]
Copyright of Salud Uninorte is the property of Fundacion Universidad del Norte and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: MedicLatina
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: lth
DbLabel: MedicLatina
An: 146563284
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Cistatina C vs. marcadores convencionales de función renal: una actualización.
– Name: TitleAlt
  Label: Alternate Title
  Group: TiAlt
  Data: Cystatin C vs conventional markers of renal function: an update.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22López%2C+Laura+Ramírez%22">López, Laura Ramírez</searchLink><relatesTo>1</relatesTo><i> lauramirez@uniboyaca.edu.co</i><br /><searchLink fieldCode="AR" term="%22Suárez%2C+Laura+Albarracín%22">Suárez, Laura Albarracín</searchLink><relatesTo>2</relatesTo><i> lxalbarracin@uniboyaca.edu.co</i><br /><searchLink fieldCode="AR" term="%22Zaraza%2C+Daniela+Castillo%22">Zaraza, Daniela Castillo</searchLink><relatesTo>2</relatesTo><i> dancastillo@uniboyaca.edu.co</i><br /><searchLink fieldCode="AR" term="%22Sánchez%2C+Julio+Bueno%22">Sánchez, Julio Bueno</searchLink><relatesTo>3</relatesTo><i> julio.bueno@udea.edu.co</i><br /><searchLink fieldCode="AR" term="%22Becerra%2C+Astrid+Aguilera%22">Becerra, Astrid Aguilera</searchLink><relatesTo>1</relatesTo><i> amaguilera@uniboyaca.edu.co</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Salud+Uninorte%22">Salud Uninorte</searchLink>. Ene-Apr2019, Vol. 35 Issue 1, p93-115. 23p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22BLOOD+urea+nitrogen%22">BLOOD urea nitrogen</searchLink><br /><searchLink fieldCode="DE" term="%22GLOMERULAR+filtration+rate%22">GLOMERULAR filtration rate</searchLink><br /><searchLink fieldCode="DE" term="%22CHRONIC+kidney+failure%22">CHRONIC kidney failure</searchLink><br /><searchLink fieldCode="DE" term="%22DIAGNOSIS%22">DIAGNOSIS</searchLink><br /><searchLink fieldCode="DE" term="%22NEEDS+assessment%22">NEEDS assessment</searchLink>
– Name: Abstract
  Label: Abstract (English)
  Group: Ab
  Data: Objective: To provide current information about the progress of the last ten years reported to improve the diagnosis of kidney disease with markers such as cystatin C, with other usual analytes used in clinical practice. Materials and methods: A search for original and review articles in english and spanish in the last ten years was carried out in the following databases: MedLine, Library Plus, ProQuest, NCBI and ScienceDirect. Results: For the evaluation of renal function markers are used such as creatinine and blood urea nitrogen. However, these tests are sometimes determined to different sources of biological variability, which is why the need to identify other markers that detect kidney damage early, and that is not influenced by pacific-dependent factors such as Cystatin C, a molecular protein of low molecular weight proposed as a marker of renal function more accurate, specific and sensitive than creatinine in modifying the glomerular filtration rate. Conclusion: Cystatin C meets with characteristics that make it a more useful biomarker in the determination of renal injury, since it shows greater diagnostic utility than serum creatinine to detect early renal damage, however, it is not used as a routine test in the diagnosis of renal pathologies due to its high cost when assembling in the clinical laboratory. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label: Abstract (Spanish)
  Group: Ab
  Data: Objetivo: Esta revisión busca proporcionar información actual de los avances de los últimos diez años reportados para mejorar el diagnóstico de enfermedad renal con marcadores como la cistatina C, en comparación con otros analitos convencionales utilizados en la práctica clínica. Materiales y métodos: Se llevó a cabo una búsqueda de artículos originales y de revisión en idioma inglés y español de los últimos diez años en las siguientes bases de datos: MedLine, Library Plus, ProQuest, NCBI y ScienceDirect. Resultados: Para la evaluación de la función renal se usan marcadores convencionales como la creatinina y el nitrógeno ureico en sangre. Sin embargo, estas pruebas están sometidas a diferentes fuentes de variabilidad biológica, razón por la cual se ve la necesidad de identificar otros marcadores que permitan detectar de forma precoz la lesión renal, y que no se vean influenciados por factores dependientes del paciente como la cistatina C, una proteína de bajo peso molecular propuesta como un marcador de función renal más exacto, específico y sensible que la creatinina en la estimación de la tasa de filtración glomerular. Conclusión: Se considera que la cistatina C cumple con características que la hacen un biomarcador más útil en la determinación de lesión renal, ya que muestra mayor utilidad diagnóstica que la creatinina sérica para detectar daño renal temprano, sin embargo, no se utiliza como prueba rutinaria en el diagnóstico de patologías renales por su alto costo al momento de realizar un montaje en el laboratorio clínico. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Salud Uninorte is the property of Fundacion Universidad del Norte and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=146563284
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.14482/sun.35.1.617.01
    Languages:
      – Code: spa
        Text: Spanish
    PhysicalDescription:
      Pagination:
        PageCount: 23
        StartPage: 93
    Subjects:
      – SubjectFull: BLOOD urea nitrogen
        Type: general
      – SubjectFull: GLOMERULAR filtration rate
        Type: general
      – SubjectFull: CHRONIC kidney failure
        Type: general
      – SubjectFull: DIAGNOSIS
        Type: general
      – SubjectFull: NEEDS assessment
        Type: general
    Titles:
      – TitleFull: Cistatina C vs. marcadores convencionales de función renal: una actualización.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: López, Laura Ramírez
      – PersonEntity:
          Name:
            NameFull: Suárez, Laura Albarracín
      – PersonEntity:
          Name:
            NameFull: Zaraza, Daniela Castillo
      – PersonEntity:
          Name:
            NameFull: Sánchez, Julio Bueno
      – PersonEntity:
          Name:
            NameFull: Becerra, Astrid Aguilera
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Text: Ene-Apr2019
              Type: published
              Y: 2019
          Identifiers:
            – Type: issn-print
              Value: 01205552
          Numbering:
            – Type: volume
              Value: 35
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Salud Uninorte
              Type: main
ResultId 1