Confiabilidad del instrumento Seguridad del Paciente en Administración de Medicamentos en Pediatría- Versión española.
Saved in:
| Title: | Confiabilidad del instrumento Seguridad del Paciente en Administración de Medicamentos en Pediatría- Versión española. |
|---|---|
| Alternate Title: | Reliability of the patient safety instrument in drug administration in pediatrics - Spanish version. Confiabilidade do instrumento Segurança do Paciente na Administração de Medicamentos na Pediatria- Versão española. |
| Authors: | Saldarriaga Sandoval, Lilia Jannet1 liyasa45@hotmail.com, Teixeira Lima, Francisca Elisângela2, César de Almeida, Paulo2, Pinheiro Barbosa, Lorena2, de Souza Gurge, Sabrina2, Maia Pascoal, Lívia3 |
| Source: | Enfermería Global. jul2021, Vol. 20 Issue 3, p330-340. 11p. |
| Abstract (English): | Objective: To evaluate the psychometric properties in terms of reliability of the instrument Patient Safety in the Administration of Medicines in Pediatrics, Spanish version. Method: Methodological study of evaluation of the psychometric properties carried out with 25 nurses from the pediatric units of a Peruvian hospital. For the evaluation of homogeneity (Cronbach's alpha), the nurses completed the instrument for Patient Safety in the Administration of Medications in Pediatrics Spanish version, composed of nine domains and 26 items; and for stability (Wilcoxon test-retest), they autocompleted the instrument again 30 days after the first collection, for comparison of both measurements. Results: In reliability, Cronbach's alpha varied from 0.792 to 0.821, considered an acceptable parameter, presenting high internal consistency, maintaining the 26 items, in the final version. In the stability of the instrument, the domains presented, in the test, a mean of 68.0 + 25.5 to 99.5 + 2.5; and in the retest 86.0 + 14.8 I tied 96 + 11.8. Six domains were found without significant difference (p> 0.05) between test and retest. Conclusion: The instrument presented psychometric properties that prove its reliability, providing subsidies for safer nursing practice and allowing standardization of care in the administration of medications. [ABSTRACT FROM AUTHOR] |
| Abstract (Spanish): | Objetivo: Evaluar las propiedades psicométricas en términos de confiabilidad del instrumento Seguridad del Paciente en la Administración de Medicamentos en Pediatria, versión española. Método: Estudio metodológico de evaluación de las propiedades psicométricas realizado con 25 enfermeras de las unidades pediátricas de un hospital peruano. Para evaluación de la homogeneidad (alfa de Cronbach) las enfermeras autocompletaron el instrumento de Seguridad del Paciente en la Administración de Medicamentos en Pediatria version española, compuesto por 9 dominios y 26 ítems; y para estabilidad (Test-retest de Wilcoxon) autocompletaron nuevamente el intrumento después de 30 dias de la primera recolección, para comparación de ambas medidas. Resultados: En la confiabilidad, el alfa de Cronbach, vario de 0,792 a 0,821, considerado un parámetro aceptable, presentando alta consistencia interna, manteniéndose los 26 ítems, en la versión final. En la estabilidad del instrumento, los dominios presentaron, en el test, media de 68,0 + 25,5 hasta 99,5 + 2,5; y en el retest 86,0 + 14,8 até 96 + 11,8. Se evidenciaron seis dominios sin diferencia significativa (p>0,05) entre test y retest. Conclusión: El instrumento presentó propiedades psicométricas que comprueban su confiabilidad, proporcionando subsídios para la práctica de enfermería más segura y permitiendo estandarización del cuidado en la administración de medicamentos. [ABSTRACT FROM AUTHOR] |
| Abstract (Portuguese): | Objetivo: Avaliar as propriedades psicométricas em termos de confiabilidade do instrumento Segurança do Paciente na Administração de Medicamentos na Pediatria, versão espanhol. Método: Estudo metodológico realizado com 25 enfermeiras das unidades pediátricas de um hospital peruano. Para avaliação da homogeneidade (alfa de Cronbach) as enfermeiras autopreencheram o SPAMP-vE, composto por nove domínios e 26 itens; e para estabilidade (Teste-reteste de Wilcoxon) autopreencheram novamente o intrumento após 30 dias da primeira coleta, para comparação de ambas medidas. Resultados: Na confiabilidade, o alfa de Cronbach, variou de 0,792 a 0,821, considerado um parâmetro aceitável, apresentando alta consistência interna, mantendo-se os 26 itens, na versão final. Na estabilidade do instrumento, os domínios apresentaram, no teste, média de 68,0 + 25,5 até 99,5 + 2,5; e no reteste 86,0 + 14,8 até 96 + 11,8. Evidenciaram-se seis domínios sem diferença significativa (p>0,05) entre teste e reteste. Conclusão: Instrumento apresentou propriedades psicométricas que comprovam sua confiabilidade, fornecendo subsídios para prática de enfermagem mais segura e permitindo padronização do cuidado na administração de medicamentos. [ABSTRACT FROM AUTHOR] |
| Copyright of Enfermería Global is the property of Servicio de Publicaciones de la Universidad de Murcia and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | MedicLatina |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: lth DbLabel: MedicLatina An: 151322566 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Confiabilidad del instrumento Seguridad del Paciente en Administración de Medicamentos en Pediatría- Versión española. – Name: TitleAlt Label: Alternate Title Group: TiAlt Data: Reliability of the patient safety instrument in drug administration in pediatrics - Spanish version.<br />Confiabilidade do instrumento Segurança do Paciente na Administração de Medicamentos na Pediatria- Versão española. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Saldarriaga+Sandoval%2C+Lilia+Jannet%22">Saldarriaga Sandoval, Lilia Jannet</searchLink><relatesTo>1</relatesTo><i> liyasa45@hotmail.com</i><br /><searchLink fieldCode="AR" term="%22Teixeira+Lima%2C+Francisca+Elisângela%22">Teixeira Lima, Francisca Elisângela</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22César+de+Almeida%2C+Paulo%22">César de Almeida, Paulo</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Pinheiro+Barbosa%2C+Lorena%22">Pinheiro Barbosa, Lorena</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22de+Souza+Gurge%2C+Sabrina%22">de Souza Gurge, Sabrina</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Maia+Pascoal%2C+Lívia%22">Maia Pascoal, Lívia</searchLink><relatesTo>3</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Enfermería+Global%22">Enfermería Global</searchLink>. jul2021, Vol. 20 Issue 3, p330-340. 11p. – Name: Abstract Label: Abstract (English) Group: Ab Data: Objective: To evaluate the psychometric properties in terms of reliability of the instrument Patient Safety in the Administration of Medicines in Pediatrics, Spanish version. Method: Methodological study of evaluation of the psychometric properties carried out with 25 nurses from the pediatric units of a Peruvian hospital. For the evaluation of homogeneity (Cronbach's alpha), the nurses completed the instrument for Patient Safety in the Administration of Medications in Pediatrics Spanish version, composed of nine domains and 26 items; and for stability (Wilcoxon test-retest), they autocompleted the instrument again 30 days after the first collection, for comparison of both measurements. Results: In reliability, Cronbach's alpha varied from 0.792 to 0.821, considered an acceptable parameter, presenting high internal consistency, maintaining the 26 items, in the final version. In the stability of the instrument, the domains presented, in the test, a mean of 68.0 + 25.5 to 99.5 + 2.5; and in the retest 86.0 + 14.8 I tied 96 + 11.8. Six domains were found without significant difference (p> 0.05) between test and retest. Conclusion: The instrument presented psychometric properties that prove its reliability, providing subsidies for safer nursing practice and allowing standardization of care in the administration of medications. [ABSTRACT FROM AUTHOR] – Name: Abstract Label: Abstract (Spanish) Group: Ab Data: Objetivo: Evaluar las propiedades psicométricas en términos de confiabilidad del instrumento Seguridad del Paciente en la Administración de Medicamentos en Pediatria, versión española. Método: Estudio metodológico de evaluación de las propiedades psicométricas realizado con 25 enfermeras de las unidades pediátricas de un hospital peruano. Para evaluación de la homogeneidad (alfa de Cronbach) las enfermeras autocompletaron el instrumento de Seguridad del Paciente en la Administración de Medicamentos en Pediatria version española, compuesto por 9 dominios y 26 ítems; y para estabilidad (Test-retest de Wilcoxon) autocompletaron nuevamente el intrumento después de 30 dias de la primera recolección, para comparación de ambas medidas. Resultados: En la confiabilidad, el alfa de Cronbach, vario de 0,792 a 0,821, considerado un parámetro aceptable, presentando alta consistencia interna, manteniéndose los 26 ítems, en la versión final. En la estabilidad del instrumento, los dominios presentaron, en el test, media de 68,0 + 25,5 hasta 99,5 + 2,5; y en el retest 86,0 + 14,8 até 96 + 11,8. Se evidenciaron seis dominios sin diferencia significativa (p>0,05) entre test y retest. Conclusión: El instrumento presentó propiedades psicométricas que comprueban su confiabilidad, proporcionando subsídios para la práctica de enfermería más segura y permitiendo estandarización del cuidado en la administración de medicamentos. [ABSTRACT FROM AUTHOR] – Name: Abstract Label: Abstract (Portuguese) Group: Ab Data: Objetivo: Avaliar as propriedades psicométricas em termos de confiabilidade do instrumento Segurança do Paciente na Administração de Medicamentos na Pediatria, versão espanhol. Método: Estudo metodológico realizado com 25 enfermeiras das unidades pediátricas de um hospital peruano. Para avaliação da homogeneidade (alfa de Cronbach) as enfermeiras autopreencheram o SPAMP-vE, composto por nove domínios e 26 itens; e para estabilidade (Teste-reteste de Wilcoxon) autopreencheram novamente o intrumento após 30 dias da primeira coleta, para comparação de ambas medidas. Resultados: Na confiabilidade, o alfa de Cronbach, variou de 0,792 a 0,821, considerado um parâmetro aceitável, apresentando alta consistência interna, mantendo-se os 26 itens, na versão final. Na estabilidade do instrumento, os domínios apresentaram, no teste, média de 68,0 + 25,5 até 99,5 + 2,5; e no reteste 86,0 + 14,8 até 96 + 11,8. Evidenciaram-se seis domínios sem diferença significativa (p>0,05) entre teste e reteste. Conclusão: Instrumento apresentou propriedades psicométricas que comprovam sua confiabilidade, fornecendo subsídios para prática de enfermagem mais segura e permitindo padronização do cuidado na administração de medicamentos. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Enfermería Global is the property of Servicio de Publicaciones de la Universidad de Murcia and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=151322566 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.6018/eglobal.442261 Languages: – Code: spa Text: Spanish PhysicalDescription: Pagination: PageCount: 11 StartPage: 330 Titles: – TitleFull: Confiabilidad del instrumento Seguridad del Paciente en Administración de Medicamentos en Pediatría- Versión española. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Saldarriaga Sandoval, Lilia Jannet – PersonEntity: Name: NameFull: Teixeira Lima, Francisca Elisângela – PersonEntity: Name: NameFull: César de Almeida, Paulo – PersonEntity: Name: NameFull: Pinheiro Barbosa, Lorena – PersonEntity: Name: NameFull: de Souza Gurge, Sabrina – PersonEntity: Name: NameFull: Maia Pascoal, Lívia IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 07 Text: jul2021 Type: published Y: 2021 Identifiers: – Type: issn-print Value: 16956141 Numbering: – Type: volume Value: 20 – Type: issue Value: 3 Titles: – TitleFull: Enfermería Global Type: main |
| ResultId | 1 |