Control de Calidad Externo en Inmunohematología del Banco de Sangre del Centro Médico Nacional. Historia y presente.

Saved in:
Bibliographic Details
Title: Control de Calidad Externo en Inmunohematología del Banco de Sangre del Centro Médico Nacional. Historia y presente.
Alternate Title: External Quality Control in Immunohematology of National Medical Center's Blood Bank. History and present.
Authors: Castillo-Mercado, Isabel1, Ignacio Galván-Bobadilla, Alexis1, Bonilla-Zavala, Ruth1, González-Moreno, Elizabeth1, Alberto Sánchez-Cañas, José1, Villegas-Martínez, Rita1, Martha Castillo-Albarrán, Fátima1, Benítez-Arvizu, Gamaliel1 gamaliel.benitez@imss.gob.mx
Source: Revista Medica del IMSS. 2023 Supplement 1, Vol. 61, pS59-S64. 6p.
Abstract (English): For the proper functioning of the Immunohematology Area, an External Quality Control was established since 1973 through a program that evaluates the performance of the laboratories of the Blood Bank and transfusion services that carry out immunohematology tests. This program consists of sending panel cells to participating blood banks or services, which are phenotyped erythrocyte samples previously studied as problem cases but whose results are unknown by the participating laboratories. The processes in which the program is of most importance are determination of the ABO group, determination of Rh, performance of the direct and indirect Coombs test, and pre-transfusion compatibility tests. It was carried out an observational and retrospective study of the results obtained in the 2020 period from 104 units participating in the Immunohematology Quality Control Program of the National Medical Center's Blood Bank. A panel of cells was sent for external quality control of immunohematology every 45 days, resulting in 9 panels for each unit in the studied period. Compliance with the program was observed in the general result (79.6%), i.e., there was a decrease in the participation of the registered units. Of a maximum score of 100% to be obtained, it was observed a general result of 95.3% compliance of the participating units. The results obtained confirm the good general training of the immunohematology laboratories of the participating units. Yet, as in any external control program, it becomes clear that obtaining an erroneous result is a risk that can occur in any laboratory. [ABSTRACT FROM AUTHOR]
Abstract (Spanish): Para el buen funcionamiento del Área de Inmunohematología, desde 1973 se instauró el Control de Calidad Externo con un programa que evalúa los laboratorios del Banco de Sangre y los servicios de transfusión que hacen pruebas de inmunohematología. El programa consiste en enviar a los bancos de sangre, o servicios participantes, células panel, que son muestras de eritrocitos fenotipados y previamente estudiados como casos problema, pero cuyos resultados son desconocidos por los laboratorios participantes. Los procesos en los que el programa es de suma importancia son determinación del grupo ABO, determinación del Rh, realización de la prueba de Coombs directa e indirecta y las pruebas de compatibilidad pretransfusionales. Se hizo un estudio observacional y retrospectivo de los resultados de 2020 de 104 unidades participantes en el Programa de Control de Calidad de Inmunohematología del Banco de Sangre del Centro Médico Nacional Siglo XXI. Se envió un panel de células para el control de calidad externo de inmunohematología cada 45 días y dio como resultado nueve paneles para cada unidad. El cumplimiento del programa se observó en el resultado general (79.6%), es decir, disminuyó la participación de las unidades inscritas. De una calificación máxima de 100%, hubo un resultado general de las unidades participantes del 95.3% de cumplimiento. Los resultados confirman la buena capacitación general de los laboratorios de inmunohematología de las unidades participantes. Aun así, como en cualquier programa de control externo, obtener un resultado erróneo es un riesgo que puede presentarse en cualquier laboratorio. [ABSTRACT FROM AUTHOR]
Copyright of Revista Medica del IMSS is the property of Direccion de Prestaciones Medicas - IMSS and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: MedicLatina
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: lth
DbLabel: MedicLatina
An: 161026539
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Control de Calidad Externo en Inmunohematología del Banco de Sangre del Centro Médico Nacional. Historia y presente.
– Name: TitleAlt
  Label: Alternate Title
  Group: TiAlt
  Data: External Quality Control in Immunohematology of National Medical Center's Blood Bank. History and present.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Castillo-Mercado%2C+Isabel%22">Castillo-Mercado, Isabel</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Ignacio+Galván-Bobadilla%2C+Alexis%22">Ignacio Galván-Bobadilla, Alexis</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Bonilla-Zavala%2C+Ruth%22">Bonilla-Zavala, Ruth</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22González-Moreno%2C+Elizabeth%22">González-Moreno, Elizabeth</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Alberto+Sánchez-Cañas%2C+José%22">Alberto Sánchez-Cañas, José</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Villegas-Martínez%2C+Rita%22">Villegas-Martínez, Rita</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Martha+Castillo-Albarrán%2C+Fátima%22">Martha Castillo-Albarrán, Fátima</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Benítez-Arvizu%2C+Gamaliel%22">Benítez-Arvizu, Gamaliel</searchLink><relatesTo>1</relatesTo><i> gamaliel.benitez@imss.gob.mx</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Revista+Medica+del+IMSS%22">Revista Medica del IMSS</searchLink>. 2023 Supplement 1, Vol. 61, pS59-S64. 6p.
– Name: Abstract
  Label: Abstract (English)
  Group: Ab
  Data: For the proper functioning of the Immunohematology Area, an External Quality Control was established since 1973 through a program that evaluates the performance of the laboratories of the Blood Bank and transfusion services that carry out immunohematology tests. This program consists of sending panel cells to participating blood banks or services, which are phenotyped erythrocyte samples previously studied as problem cases but whose results are unknown by the participating laboratories. The processes in which the program is of most importance are determination of the ABO group, determination of Rh, performance of the direct and indirect Coombs test, and pre-transfusion compatibility tests. It was carried out an observational and retrospective study of the results obtained in the 2020 period from 104 units participating in the Immunohematology Quality Control Program of the National Medical Center's Blood Bank. A panel of cells was sent for external quality control of immunohematology every 45 days, resulting in 9 panels for each unit in the studied period. Compliance with the program was observed in the general result (79.6%), i.e., there was a decrease in the participation of the registered units. Of a maximum score of 100% to be obtained, it was observed a general result of 95.3% compliance of the participating units. The results obtained confirm the good general training of the immunohematology laboratories of the participating units. Yet, as in any external control program, it becomes clear that obtaining an erroneous result is a risk that can occur in any laboratory. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label: Abstract (Spanish)
  Group: Ab
  Data: Para el buen funcionamiento del Área de Inmunohematología, desde 1973 se instauró el Control de Calidad Externo con un programa que evalúa los laboratorios del Banco de Sangre y los servicios de transfusión que hacen pruebas de inmunohematología. El programa consiste en enviar a los bancos de sangre, o servicios participantes, células panel, que son muestras de eritrocitos fenotipados y previamente estudiados como casos problema, pero cuyos resultados son desconocidos por los laboratorios participantes. Los procesos en los que el programa es de suma importancia son determinación del grupo ABO, determinación del Rh, realización de la prueba de Coombs directa e indirecta y las pruebas de compatibilidad pretransfusionales. Se hizo un estudio observacional y retrospectivo de los resultados de 2020 de 104 unidades participantes en el Programa de Control de Calidad de Inmunohematología del Banco de Sangre del Centro Médico Nacional Siglo XXI. Se envió un panel de células para el control de calidad externo de inmunohematología cada 45 días y dio como resultado nueve paneles para cada unidad. El cumplimiento del programa se observó en el resultado general (79.6%), es decir, disminuyó la participación de las unidades inscritas. De una calificación máxima de 100%, hubo un resultado general de las unidades participantes del 95.3% de cumplimiento. Los resultados confirman la buena capacitación general de los laboratorios de inmunohematología de las unidades participantes. Aun así, como en cualquier programa de control externo, obtener un resultado erróneo es un riesgo que puede presentarse en cualquier laboratorio. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Revista Medica del IMSS is the property of Direccion de Prestaciones Medicas - IMSS and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=161026539
RecordInfo BibRecord:
  BibEntity:
    Languages:
      – Code: spa
        Text: Spanish
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: S59
    Titles:
      – TitleFull: Control de Calidad Externo en Inmunohematología del Banco de Sangre del Centro Médico Nacional. Historia y presente.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Castillo-Mercado, Isabel
      – PersonEntity:
          Name:
            NameFull: Ignacio Galván-Bobadilla, Alexis
      – PersonEntity:
          Name:
            NameFull: Bonilla-Zavala, Ruth
      – PersonEntity:
          Name:
            NameFull: González-Moreno, Elizabeth
      – PersonEntity:
          Name:
            NameFull: Alberto Sánchez-Cañas, José
      – PersonEntity:
          Name:
            NameFull: Villegas-Martínez, Rita
      – PersonEntity:
          Name:
            NameFull: Martha Castillo-Albarrán, Fátima
      – PersonEntity:
          Name:
            NameFull: Benítez-Arvizu, Gamaliel
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 02
              M: 01
              Text: 2023 Supplement 1
              Type: published
              Y: 2023
          Identifiers:
            – Type: issn-print
              Value: 04435117
          Numbering:
            – Type: volume
              Value: 61
          Titles:
            – TitleFull: Revista Medica del IMSS
              Type: main
ResultId 1